Biomechanical properties of adipose tissue (AT) are closely involved in the development of obesity-associated comorbidities. Bariatric surgery (BS) constitutes the most effective option for a sustained weight loss in addition to improving obesity-associated metabolic diseases including type 2 diabetes (T2D). We aimed to determine the impact of weight loss achieved by BS and caloric restriction (CR) on the biomechanical properties of AT. BS but not CR changed the biomechanical properties of epididymal white AT (EWAT) from a diet-induced obesity rat model, which were associated with metabolic improvements. We found decreased gene expression levels of collagens and Lox together with increased elastin and Mmps mRNA levels in EWAT after BS, which were also associated with the biomechanical properties. Moreover, an increased blood vessel density was observed in EWAT after surgery, confirmed by an upregulation of Acta2 and Antxr1 gene expression levels, which was also correlated with the biomechanical properties. Visceral AT from patients with obesity showed increased stiffness after tensile tests compared to the EWAT from the animal model. This study uncovers new insights into EWAT adaptation after BS with decreased collagen crosslink and synthesis as well as an increased degradation together with enhanced blood vessel density providing, simultaneously, higher stiffness and more ductility. STATEMENT OF SIGNIFICANCE: Biomechanical properties of the adipose tissue (AT) are closely involved in the development of obesity-associated comorbidities. In this study, we show for the first time that biomechanical properties of AT determined by E, UTS and strain at UTS are decreased in obesity, being increased after bariatric surgery by the promotion of ECM remodelling and neovascularization. Moreover, these changes in biomechanical properties are associated with improvements in metabolic homeostasis. Consistently, a better characterization of the plasticity and biomechanical properties of the AT after bariatric surgery opens up a new field for the development of innovative strategies for the reduction of fibrosis and inflammation in AT as well as to better understand obesity and its associated comorbidities.
Background: Tear film stability is the key event in ocular surface diseases. The purpose of this study is to evaluate spatial and temporal progression of the tear film breakup using an automatic non-invasive device. Methods: Non-invasive tear breakup time (NITBUT) parameters, such as First NITBUT (F-NITBUT) and Average NITBUT (A-NITBUT), were evaluated in 132 glaucoma and 87 control eyes with the Keratograph 5 M device. Further analysis of this data was used to determine size, location and progression of tear film breakup with automatically identified breakup areas (BUA). The progression from First BUA (F-BUA) to total BUA (T-BUA) was expressed as Dry Area Growth Rate (DAGR). Differences between both groups were analysed using Student t-test for parametric data and Mann-Whitney U test for non-parametric data. Pearson’s correlation coefficient was used to assess the relationship between parametric variables and Spearman in the case of non-parametric variables. Results: F-NITBUT was 11.43 ± 7.83 s in the control group and 8.17 ± 5.73 in the glaucoma group (P = 0.010). A-NITBUT was 14.04 ± 7.21 and 11.82 ± 6.09 s in control and glaucoma groups, respectively (P = 0.028). F-BUA was higher in the glaucoma group than in the control group (2.73 and 2.28; P = 0.022) and was more frequently located at the centre of the cornea in the glaucoma group (P = 0.039). T-BUA was also higher in the glaucoma group than in the control group (13.24 and 9.76%; P = 0.012) and the DAGR was steeper in the glaucoma group than in the control group (34.38° and 27.15°; P = 0.009). Conclusions: Shorter NITBUT values and bigger, more central tear film breakup locations were observed in the glaucoma group than in the control group. The DAGR indicates that tear film rupture is bigger and increases faster in glaucomatous eyes than in normal eyes.
Purpose There are many physiological parameters recorded by devices that are becoming more affordable, precise and accurate. However, the lack of development in the recording of voice parameters from the physiological or medical point of view is striking, given that it is a fundamental tool for the work of many people and given the high incidence and prevalence of voice pathologies that affect people's communication. In this paper we perform a complete literature review on the dosimeters used in voice research and to present a prototype dosimeter with a pilot study to show its capabilities. Method We conducted a literature review using the keywords [MONITORING], [PHONATION], [ACCUMULATOR], [PORTABLE], [DOSIMETRY], [VOICE] searching in PubMed, Trip Database, HONcode, and SciELO search engines. From our review of dosimeter designs, we created our own prototype consisting of two main components: a Knowles Electronics BU-7135-0000 accelerometer mounted on a neck brace; and the ultra-low power MSP430FR5994 microcontroller. The selected sampling frequency was 2048 Hz. The device calculates the F0 every 250 ms and the amplitude and phonation activity every 31.25 ms. A pilot study was conducted using 2 subjects: one male during 11 days and one female during 14 days. Results This work includes devices that have been created during the last 45 years as tools for the diagnosis and monitoring of the treatment of cases of vocal pathology and for the detection of phonatory patterns or risk situations for developing voice disorders or vocal pathologies. We also present recordings with our new device on the pattern of daily talk time, the fundamental frequency and the relative intensity of two subjects on different days. Conclusions Interesting work has been done in the development of voice dosimeters with different approaches. In our experience it is not possible to access them for research and they are not yet in clinical use. It is possible that a joint approach with voice and voice disorders professionals and engineers working closely together could take advantage of current technology to develop a fully portable, useful, and efficient system.
22 April 2026 in Perspectives on Medical Education
Background: Multiple-choice questions (MCQs) are widely used in medical education due to their efficiency and scalability. However, the quality of distractors plays a critical role in item validity. Evidence suggests that reducing distractors may enhance psychometric performance without compromising assessment quality. Methods: We conducted a randomized study involving 198 MCQs used in second-year medical exams at the University of Navarra. Each exam included 50 items with two distractors and 50 with three distractors. Items were analyzed for difficulty index, point-biserial coefficient, low-functioning distractors, item-writing flaws, and overall quality (difficulty index 0.45–0.75 and point-biserial > 0.20). In addition, items were classified as either factual recall or clinical case-based to assess the effect of question type. Univariate and multivariate analyses were performed. Results: No significant differences were found between two- and three-distractor items in terms of difficulty, discrimination, or overall quality. However, items with two distractors presented fewer item-writing flaws (60.2% versus 46%; p = 0.045) and more frequently all their distractors were functional (38.8% versus 18%; p = 0.01). Factual questions were easier and more likely to contain poor distractors, while clinical-case items were more complex and discriminative. Multivariate analyses confirmed that distractor quality, not quantity, was the main factor associated with item performance. Conclusions: Multiple-choice questions with two well-constructed distractors are a valid and efficient alternative to traditional formats. Reducing the number of distractors improves distractor quality and reduces writing flaws, without compromising psychometric standards. These findings support a shift toward more streamlined item formats in medical education assessment.