Karl Pflanz

Karl Pflanz

Auto-generated profile, based on publicly available information

Karl Pflanz

Lab Essentials Applications Development, Sartorius Stedim Biotech GmbH, August-Spindler-Straße 11, 37079 Göttingen, Germany

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 May 2022 in Journal of Chromatography A
Verified
Journal Article
Open access
JLJennifer Julia Labisch
Jennifer Julia Labisch
MKMeriem Kassar
Meriem Kassar
FBFranziska Bollmann
Franziska Bollmann
AVAngela Valentic
Angela Valentic
JHJürgen Hubbuch
Jürgen Hubbuch
KPKarl Pflanz
Karl Pflanz
Enveloped viral vectors like lentiviral vectors pose purification challenges due to their low stability. A gentle purification method is considered one of the major bottlenecks for lentiviral vector bioprocessing. To overcome these challenges, a promising method is steric exclusion chromatography which has been used to purify a variety of target molecules. In this study, we successfully identified optimal process parameters for steric exclusion chromatography to purify lentiviral vectors. Lentiviral vector particle recoveries and infectious recoveries of 86% and 88%, respectively, were achieved. The process parameters optimal for steric exclusion chromatography were determined as follows: polyethylene glycol with a molecular weight of 4000 Da, a polyethylene glycol concentration of 12.5%, and a flow rate of 7 mL⋅min-1 using 5 layers of stabilized cellulose membranes as a stationary phase. High protein and dsDNA removal of approximately 80% were obtained. The remaining polyethylene glycol concentration in the eluate was determined. We defined the maximum loading capacity as 7.5 × 1012 lentiviral particles for the lab device used and provide deeper insights into loading strategies. Furthermore, we determined critical process parameters like pressure. We demonstrated in our experiments that steric exclusion chromatography is a gentle purification method with high potential for fragile enveloped viral vectors as it yields high recoveries while efficiently removing impurities.

9 October 2024 in Biotechnology Journal
Verified
Journal Article
Open access
FMFrederik Meierrieks
Frederik Meierrieks
AWAlisa Weltken
Alisa Weltken
KPKarl Pflanz
Karl Pflanz
APAndreas Pickl
Andreas Pickl
BGBenjamin Graf
Benjamin Graf
Michael Werner WolffMichael Werner Wolff
Michael Werner Wolff
Adeno‐associated viruses (AAV) are widely used viral vectors for in vivo gene therapy. The purification of AAV, particularly the separation of genome‐containing from empty AAV capsids, is usually time‐consuming and requires expensive equipment. In this study, we present a novel laboratory scale anion exchange flow‐through polishing method designed to separate full and empty AAV. Once the appropriate conditions are defined, this method eliminates the need for a chromatography system. Determination of optimal polishing conditions using a chromatography system revealed that the divalent salt MgCl2 resulted in better separation of full and empty AAV than the monovalent salt NaCl. The efficacy of the method was demonstrated for three distinct AAV serotypes (AAV8, AAV5, and AAV2) on two different stationary phases: a membrane adsorber and a monolith, resulting in a 4‐ to 7.5‐fold enrichment of full AAV particles. Moreover, the method was shown to preserve the AAV capsids’ functional potency and structural integrity. Following the successful establishment of the flow‐through polishing approach, it was adapted to a manual syringe‐based system. Manual flow‐through polishing using the monolith or membrane adsorber achieved 3.6‐ and 5.4‐fold enrichment of full AAV, respectively. This study demonstrates the feasibility of separating full and empty AAV without complex linear or step gradient elution and the necessity of specialized equipment. Flow‐through polishing provides a rapid and easy‐to‐perform platform for polishing multiple vector preparations, addressing a critical aspect in the research and development of novel gene therapies.

8 March 2023 in Separations
Verified
Journal Article
Open access
PDF file
JLJennifer Julia Labisch
Jennifer Julia Labisch
GWG. Philip Wiese
G. Philip Wiese
KPKarl Pflanz
Karl Pflanz
Steric exclusion chromatography (SXC) is a purification method that is based on steric exclusion effects from the surface of the target and a hydrophilic stationary phase after the addition of polyethylene glycol (PEG), which leads to an association of the target with the stationary phase without direct binding, such as covalent, electrostatic, and hydrophilic/hydrophobic interactions. The gentle nature of the method has led to an increased focus on sensitive targets such as enveloped viruses with potential for other sensitive entities, e.g., extracellular vesicles and virus-like particles. SXC is related to PEG-mediated protein precipitation, but investigation of further process parameters was crucial to gain a better understanding of the SXC method. After explaining mechanistic fundamentals and their discovery, this review summarizes the findings on SXC from its first reference 11 years ago until today. Different applications of SXC are presented, demonstrating that the method can be used for a wide variety of targets and achieves high recovery rates and impurity removal. Further, critical process parameters for successful process implementation are discussed, including technical requirements, buffer composition, and scalability.

20 September 2023 in Molecular Therapy - Methods & Clinical Development
Verified
Journal Article
Open access
FMFrederik Meierrieks
Frederik Meierrieks
AKAhmad Kour
Ahmad Kour
MPMarvin Pätz
Marvin Pätz
KPKarl Pflanz
Karl Pflanz
Michael Werner WolffMichael Werner Wolff
Michael Werner Wolff
APAndreas Pickl
Andreas Pickl
Adeno-associated virus (AAV) vectors are among the most prominent viral vectors for in vivo gene therapy, and their investigation and development using high-throughput techniques have gained increasing interest. However, sample throughput remains a bottleneck in most analytical assays. In this study, we compared commonly used analytical methods for AAV genome titer, capsid titer, and transducing titer determination with advanced methods using AAV2, AAV5, and AAV8 as representative examples. For the determination of genomic titers, we evaluated the suitability of qPCR and four different digital PCR methods and assessed the respective advantages and limitations of each method. We found that both ELISA and bio-layer interferometry provide comparable capsid titers, with bio-layer interferometry reducing the workload and having a 2.8-fold higher linear measurement range. Determination of the transducing titer demonstrated that live-cell analysis required less manual effort compared with flow cytometry. Both techniques had a similar linear range of detection, and no statistically significant differences in transducing titers were observed. This study demonstrated that the use of advanced analytical methods provides faster and more robust results while simultaneously increasing sample throughput and reducing active bench work time.

24 January 2023 in Membranes
Verified
Journal Article
Open access
PDF file
JLJennifer Julia Labisch
Jennifer Julia Labisch
RPRichard Paul
Richard Paul
GWG. Philip Wiese
G. Philip Wiese
KPKarl Pflanz
Karl Pflanz
Lentiviral vectors (LVs) are widely used in clinical trials of gene and cell therapy. Low LV stability incentivizes constant development and the improvement of gentle process steps. Steric exclusion chromatography (SXC) has gained interest in the field of virus purification but scaling up has not yet been addressed. In this study, the scaling up of lentiviral vector purification by SXC with membrane modules was approached. Visualization of the LVs captured on the membrane during SXC showed predominant usage of the upper membrane layer. Furthermore, testing of different housing geometries showed a strong influence on the uniform usage of the membrane. The main use of the first membrane layer places a completely new requirement on the scaling of the process and the membrane modules. When transferring the SXC process to smaller or larger membrane modules, it became apparent that scaling of the flow rate is a critical factor that must be related to the membrane area of the first layer. Performing SXC at different scales demonstrated that a certain critical minimum surface area-dependent flow rate is necessary to achieve reproducible LV recoveries. With the presented scaling approach, we were able to purify 980 mL LVs with a recovery of 68%.

11 January 2025 in Journal of Chromatography A
Verified
Journal Article
Open access
FMFrederik Meierrieks
Frederik Meierrieks
JRJuan-Carlos Rosario
Juan-Carlos Rosario
LRLena Rübeling
Lena Rübeling
HAHatice Asikoglu
Hatice Asikoglu
KPKarl Pflanz
Karl Pflanz
BGBenjamin Graf
Benjamin Graf
Adeno-associated viruses (AAV) are among the leading vectors for in vivo gene therapy. The purification of AAV remains a bottleneck as it typically requires multiple individual process steps, often resulting in product loss and high costs. Current downstream processes are usually serotype-specific and rely primarily on expensive affinity resins. To address these limitations, we developed a serotype-independent purification method using steric exclusion chromatography (SXC) that can be combined with a subsequent anion exchange full/empty separation step. This alternative approach eliminates the need for intermediate concentration and buffer exchange, thereby reducing the number of process steps required while achieving high-purity full AAV particles. SXC conditions were optimized using a design of experiments approach. Isocratic separation of full and empty AAV resulted in further purification of the sample. The overall process achieved a viral genome recovery of 51.7 %, along with impurity depletions of 99.9 % for DNA and 99.8 % for protein. The process was successfully adapted to different AAV serotypes and genes of interest, demonstrating its robustness and versatility. In addition, the scalability of SXC was demonstrated, highlighting its potential for large-scale manufacturing. This streamlined, universal, and scalable process provides a robust and efficient alternative to traditional AAV purification processes, addressing critical challenges in gene therapy production and paving the way for broader implementation in research and manufacturing.