Thiwabhorn Thaweewannakij

Thiwabhorn Thaweewannakij

Auto-generated profile, based on publicly available information

Thiwabhorn Thaweewannakij

School of Physical Therapy, Faculty of Associated Medical Science, Khon Kaen University, Khon Kaen, Thailand

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 December 2018 in Musculoskeletal Science and Practice
Verified
Journal Article
Closed access
AWArpassanan Wiyanad
Arpassanan Wiyanad
PCPakwipa Chokphukiao
Pakwipa Chokphukiao
PSPatcharawan Suwannarat
Patcharawan Suwannarat
TTThiwabhorn Thaweewannakij
Thiwabhorn Thaweewannakij
PWPattra Wattanapan
Pattra Wattanapan
SASugalya Amatachaya
Sugalya Amatachaya

15 January 2024 in Turkish Journal of Physical Medicine and Rehabilitation
Verified
Journal Article
Open access
RIRoongnapa Intaruk
Roongnapa Intaruk
SPSupaporn Phadungkit
Supaporn Phadungkit
AKAnongnat Kanpai
Anongnat Kanpai
KPKetmanee Pawanta
Ketmanee Pawanta
NSNuttanicha Srihapol
Nuttanicha Srihapol
TTThiwabhorn Thaweewannakij
Thiwabhorn Thaweewannakij
Objectives: This study aimed to quantify test-retest reliability and minimal detectable change (MDC) of the four commonly used functional tests in older adults with a high risk of falling. Patients and methods: The cross-sectional study was conducted with 30 community-dwelling older adults (26 females, 4 males; mean age: 73.7±6.0 years; range, 65 to 88 years) with a high fall risk identified by the Thai falls risk assessment test between November 2018 and May 2019. Data from the 10-m walk test at a comfortable gait speed (CGS) and fast gait speed (FGS), timed up and go (TUG) test, five times sit to stand test (FTSST), and 6-min walk test (6MWT) were collected twice for each participant. The interval between test sessions was one week. Test-retest reliability was analyzed by the intraclass correlation coefficient (ICC). Standard error of measurement (SEM) and MDC at the 95% confidence interval (MDC 95 ) were also calculated. Results: The four functional tests had ICC in the range of 0.92 to 0.97. The SEM values of the CGS, FGS, TUG, FTSST, and 6MWT were 0.06 m/sec, 0.04 m/sec, 1.10 sec, 1.30 sec, and 20.60 m, respectively. The MDC 95 values of the CGS, FGS, TUG, FTSST, and 6MWT were 0.16 m/sec, 0.12 m/sec, 3.00 sec, 3.50 sec, and 57.20 m, respectively. Conclusion: All functional tests demonstrated excellent test-retest reliability. The SEM and MDC 95 of all functional tests were established. These findings can help clinicians interpret the effectiveness of interventions and determine changes in functional ability over time in older adults at high risk of falls.

7 September 2021 in Physiotherapy Theory and Practice
Verified
Journal Article
Closed access
PCPakwipa Chokphukiao
Pakwipa Chokphukiao
AWArpassanan Wiyanad
Arpassanan Wiyanad
PSPatcharawan Suwannarat
Patcharawan Suwannarat
SASugalya Amatachaya
Sugalya Amatachaya
LMLugkana Mato
Lugkana Mato
TTThiwabhorn Thaweewannakij
Thiwabhorn Thaweewannakij
This study aimed to investigate the concurrent validity of the block method as compared with the gold standard (Cobb’s method). An additional aim was to examine the intra- and inter-rater reliabili...