5 February 2020 in Journal of The Royal Society Interface
The retina is composed of two main layers—the neuroretina and the retinal pigment epithelium (RPE)—that are separated by a potential gap termed the sub-retinal space (SRS). Accumulation of fluid in the SRS may result in a retinal detachment. A key function of the RPE is to prevent fluid accumulation in the SRS by actively pumping fluid from this space to the choroid. We have developed a mathematical model of this process that incorporates the transport of seven chemical species: Na + , K + , Cl − , , H + , CO 2 and H 2 CO 3 . This allows us to estimate solute and water fluxes and to understand the role of the different membrane ion channels. We have performed a global sensitivity analysis using the extended Fourier amplitude sensitivity test to investigate the relative importance of parameters in generating the model outputs. The model predicts that flow across the RPE is driven by an osmotic gradient in the cleft gap between adjacent cells. Moreover, the model estimates how water flux is modified in response to inhibition of membrane ion channels and carbonic anhydrase (CA). It provides a possible explanation for how CA inhibitors, which are used clinically to prevent fluid accumulation in the SRS, may be acting.
16 April 2021 in Soft Matter
Motivated by recent experiments demonstrating that motile algae get trapped in draining foams, we study the trajectories of microorganisms confined in model foam channels (section of a Plateau border). We track single Chlamydomonas reinhardtii cells confined in a thin three-circle microfluidic chamber and show that their spatial distribution exhibits strong corner accumulation. Using empirical scattering laws observed in previous experiments (scattering with a constant scattering angle), we next develop a two-dimension geometrical model and compute the phase space of trapped and periodic trajectories of swimmers inside a three-circles billiard. We find that the majority of cell trajectories end up in a corner, providing a geometrical mechanism for corner accumulation. Incorporating the distribution of scattering angles observed in our experiments and including hydrodynamic interactions between the cells and the surfaces into the geometrical model enables us to reproduce the experimental probability density function of micro-swimmers in microfluidic chambers. Both our experiments and models demonstrate therefore that motility leads generically to trapping in complex geometries.
30 October 2017 in Mathematical Medicine and Biology: A Journal of the IMA
The anterior chamber (AC) and posterior chamber (PC) of the eye are connected through the pupil and are filled with aqueous humour. The aqueous flows from the posterior to the AC at an approximately constant rate, and the intraocular pressure is governed by this rate and the resistance to aqueous outflow. In some patients the iris and lens come into contact, leading to pressure build-up in the PC, peripheral axial shallowing of the AC and, possibly, to angle-closure glaucoma. This can lead to blindness, which may be prevented by surgically creating an iridotomy, that is a hole through the iris to facilitate the flow from the posterior to the AC. The problem of optimal size and location of an iridotomy is still poorly understood. In this article, we study aqueous flow in the PC and investigate how it is modified in the presence of an iridotomy. Our approach is based on the lubrication theory, which allows us to solve the problem semi-analytically. We treat the iridotomy as a point sink and assume that the flux through it is proportional to the pressure. We find that the ideal size and location of an iridotomy are influenced by various geometrical and fluid mechanical factors, the most relevant of which are the size of the hole and the length and height of the iris–lens channel. For certain iridotomy diameters, we find that the jet velocity through the iridotomy might be large enough to cause possible corneal damage.
1 November 2018 in Journal of Theoretical Biology
28 January 2019 in Journal of Fluid Mechanics
We study the flow induced by eye rotations in the anterior chamber (AC) of the eye, the region between the cornea and the iris. We model the geometry of the AC as a thin domain sitting on the surface of a sphere, and study both the simpler case of a constant-height domain as well as a more realistic AC shape. We model eye rotations as harmonic in time with prescribed frequency $\unicode[STIX]{x1D714}_{f}$ and amplitude $\unicode[STIX]{x1D6FD}$ , and use lubrication theory to simplify the governing equations. We write the equations in a reference frame moving with the domain and show that fluid motion is governed by three dimensionless parameters: the aspect ratio $\unicode[STIX]{x1D716}$ of the AC, the angular amplitude $\unicode[STIX]{x1D6FD}$ and the Womersley number $\unicode[STIX]{x1D6FC}$ . We simplify the equations under the physiologically realistic assumptions that $\unicode[STIX]{x1D716}$ is small and $\unicode[STIX]{x1D6FC}$ large, leading to a linear system that can be decomposed into three harmonics: a dominant frequency component, with frequency $\unicode[STIX]{x1D714}_{f}$ , and a steady streaming component and a third component with frequency $2\unicode[STIX]{x1D714}_{f}$ . We solve the problem analytically for the constant-height domain and numerically as the solution of ordinary differential equations in the more realistic geometry. Both the primary flow and the steady streaming are shown to have a highly three-dimensional structure, which has not been highlighted in previous numerical works. We show that the steady streaming is particularly relevant from the clinical point of view, as it induces fluid mixing in the AC. Furthermore, the steady flow component is the dominant mixing mechanism during the night, when the thermal flow induced by temperature variations across the AC is suppressed.