Jonathan M. Behar

Jonathan M. Behar

Auto-generated profile, based on publicly available information

Jonathan M. Behar

School of Biomedical Engineering & Imaging Sciences, King’s College London, St Thomas Hospital, London SE1 7EH, UK

Research Focus & Metrics

Academic Career Length

20Years (2007-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 December 2016 in JACC: Clinical Electrophysiology
Verified
Journal Article
Open access
JBJonathan M. Behar
Jonathan M. Behar
TJTom Jackson
Tom Jackson
EHEoin Hyde
Eoin Hyde
SCSimon Claridge
Simon Claridge
JGJaswinder Gill
Jaswinder Gill
CRChristopher Aldo Rinaldi
Christopher Aldo Rinaldi
The purpose of this study was to identify the optimal pacing site for the left ventricular (LV) lead in ischemic patients with poor response to cardiac resynchronization therapy (CRT). LV endocardial pacing may offer benefit over conventional CRT in ischemic patients. We performed cardiac magnetic resonance, invasive electroanatomic mapping (EAM), and measured the acute hemodynamic response (AHR) in patients with existing CRT systems. In all, 135 epicardial and endocardial pacing sites were tested in 8 patients. Endocardial pacing was superior to epicardial pacing with respect to mean AHR (% change in dP/dtmax vs. baseline) (11.81 [-7.2 to 44.6] vs. 6.55 [-11.0 to 19.7]; p = 0.025). This was associated with a similar first ventricular depolarization (Q-LV) (75 ms [13 to 161 ms] vs. 75 ms [25 to 129 ms]; p = 0.354), shorter stimulation–QRS duration (15 ms [7 to 43 ms] vs. 19 ms [5 to 66 ms]; p = 0.010) and shorter paced QRS duration (149 ms [95 to 218 ms] vs. 171 ms [120 to 235 ms]; p < 0.001). The mean best achievable AHR was higher with endocardial pacing (25.64 ± 14.74% vs. 12.64 ± 6.76%; p = 0.044). Furthermore, AHR was significantly greater pacing the same site endocardially versus epicardially (15.2 ± 10.7% vs. 7.6 ± 6.3%; p = 0.014) with a shorter paced QRS duration (137 ± 22 ms vs. 166 ± 30 ms; p < 0.001) despite a similar Q-LV (70 ± 38 ms vs. 79 ± 34 ms; p = 0.512). Lack of capture due to areas of scar (corroborated by EAM and cardiac magnetic resonance) was associated with a poor AHR. In ischemic patients with poor CRT response, biventricular endocardial pacing is superior to epicardial pacing. This may reflect accessibility to sites that cannot be reached via coronary sinus anatomy and/or by access to more rapidly conducting tissue. Furthermore, guidance to the optimal LV pacing site may be aided by modalities such as cardiac magnetic resonance to target delayed activating sites while avoiding scar.

1 September 2017 in Heart Rhythm
Verified
Journal Article
Open access
JBJonathan M. Behar
Jonathan M. Behar
RRRonak Rajani
Ronak Rajani
APAmir Pourmorteza
Amir Pourmorteza
RPRebecca Preston
Rebecca Preston
OROrod Razeghi
Orod Razeghi
CRChristopher Aldo Rinaldi
Christopher Aldo Rinaldi
Optimal lead positioning is an important determinant of cardiac resynchronization therapy (CRT) response. The purpose of this study was to evaluate cardiac computed tomography (CT) selection of the optimal epicardial vein for left ventricular (LV) lead placement by targeting regions of late mechanical activation and avoiding myocardial scar. Eighteen patients undergoing CRT upgrade with existing pacing systems underwent preimplant electrocardiogram-gated cardiac CT to assess wall thickness, hypoperfusion, late mechanical activation, and regions of myocardial scar by the derivation of the stretch quantifier for endocardial engraved zones (SQUEEZ) algorithm. Cardiac venous anatomy was mapped to individualized American Heart Association (AHA) bull's-eye plots to identify the optimal venous target and compared with acute hemodynamic response (AHR) in each coronary venous target using an LV pressure wire. Fifteen data sets were evaluable. CT-SQUEEZ-derived targets produced a similar mean AHR compared with the best achievable AHR (20.4% ± 13.7% vs 24.9% ± 11.1%; P = .36). SQUEEZ-derived guidance produced a positive AHR in 92% of target segments, and pacing in a CT-SQUEEZ target vein produced a greater clinical response rate vs nontarget segments (90% vs 60%). Preprocedural CT-SQUEEZ-derived target selection may be a valuable tool to predict the optimal venous site for LV lead placement in patients undergoing CRT upgrade.

1 August 2017 in JACC: Clinical Electrophysiology
Verified
Journal Article
Open access
JBJonathan M. Behar
Jonathan M. Behar
PMPeter Mountney
Peter Mountney
DTDaniel Toth
Daniel Toth
SRSabrina Reiml
Sabrina Reiml
MPMaria Panayiotou
Maria Panayiotou
CRChristopher Aldo Rinaldi
Christopher Aldo Rinaldi
This study sought to test the feasibility of a purpose-built, integrated software platform to process, analyze, and overlay cardiac magnetic resonance (CMR) data in real time within a combined cardiac catheter laboratory and magnetic resonance imaging scanner suite (X-MRI) to guide left ventricular (LV) lead implantation. Suboptimal LV lead position is a major determinant of poor cardiac resynchronization therapy (CRT) response, and the optimal site is highly patient specific. Pacing myocardial scar is associated with poorer outcomes; conversely, targeting latest mechanical activation (LMA) may improve them. Fourteen patients (age 74 ± 5.1 years; New York Heart Association functional class: 2.7 ± 0.4; 86% ischemic with ejection fraction 27 ± 7.6%; QRSd: 157 ± 19 ms) underwent CMR followed by immediate CRT implantation using derived scar and dyssynchrony data, overlaid onto fluoroscopy in an X-MRI suite. Rapid LV segmentation enabled detailed scar quantification, identification of LMA segments, and selection of myocardial targets. At coronary venography, the CMR-derived 3-dimensional shell was fused, enabling identification of viable venous targets subtended by target segments for LV lead placement. The platform was successful in all 14 patients, of whom 10 (71%) were paced in pre-procedurally defined target segments. Pacing in CMR-defined target segments (out of scar) showed a significant decrease in the LV capture threshold (mean difference: 2.4 [1.5 to 3.2]; p < 0.001) and shorter paced QRS duration (mean difference: 25 [15 to 34]; p < 0.001) compared with pacing in areas of CMR determined scar. In 5 (36%) patients with extensive scar in the posterolateral wall, CMR guidance enabled successful lead delivery in an alternative anatomically favorable site. Radiation dose and implant times were similar to historical controls (p = NS). Real-time CMR-guided LV lead placement is feasible and achievable in a single clinical setting and may prove helpful to preferentially select sites for LV lead placement.

1 March 2024 in Circulation: Arrhythmia and Electrophysiology
Verified
Journal Article
Open access
MAMaclean
Maclean
KMKarishma Mahtani
Karishma Mahtani
SHShohreh Honarbakhsh
Shohreh Honarbakhsh
CBCharles Butcher
Charles Butcher
NANikhil Ahluwalia
Nikhil Ahluwalia
ACAnthony Chow
Anthony Chow
BACKGROUND: Antimicrobial envelopes reduce the incidence of cardiac implantable electronic device infections, but their cost restricts routine use in the United Kingdom. Risk scoring could help to identify which patients would most benefit from this technology. METHODS: A novel risk score (BLISTER [Blood results, Long procedure time, Immunosuppressed, Sixty years old (or younger), Type of procedure, Early re-intervention, Repeat procedure]) was derived from multivariate analysis of factors associated with cardiac implantable electronic device infection. Diagnostic utility was assessed against the existing PADIT score (Prior procedure, Age, Depressed renal function, Immunocompromised, Type of procedure) in both standard and high-risk external validation cohorts, and cost-utility models examined different BLISTER and PADIT score thresholds for TYRX (Medtronic; Minneapolis, MN) antimicrobial envelope allocation. RESULTS: In a derivation cohort (n=7383), cardiac implantable electronic device infection occurred in 59 individuals within 12 months of a procedure (event rate, 0.8%). In addition to the PADIT score constituents, lead extraction (hazard ratio, 3.3 [95% CI, 1.9–6.1]; P 50 mg/L (hazard ratio, 3.0 [95% CI, 1.4–6.4]; P =0.005), reintervention within 2 years (hazard ratio, 10.1 [95% CI, 5.6–17.9]; P <0.0001), and top-quartile procedure duration (hazard ratio, 2.6 [95% CI, 1.6–4.1]; P =0.001) were independent predictors of infection. The BLISTER score demonstrated superior discriminative performance versus PADIT in the standard risk (n=2854, event rate: 0.8%, area under the curve, 0.82 versus 0.71; P =0.001) and high-risk validation cohorts (n=1961, event rate: 2.0%, area under the curve, 0.77 versus 0.69; P =0.001), and in all patients (n=12 198, event rate: 1%, area under the curve, 0.8 versus 0.75, P =0.002). In decision-analytic modeling, the optimum scenario assigned antimicrobial envelopes to patients with BLISTER scores ≥6 (10.8%), delivering a significant reduction in infections (relative risk reduction, 30%; P =0.036) within the National Institute for Health and Care Excellence cost-utility thresholds (incremental cost-effectiveness ratio, £18 446). CONCLUSIONS: The BLISTER score ( https://qxmd.com/calculate/calculator_876/the-blister-score-for-cied-infection ) was a valid predictor of cardiac implantable electronic device infection, and could facilitate cost-effective antimicrobial envelope allocation to high-risk patients.

1 February 2017 in JACC: Clinical Electrophysiology
Verified
Journal Article
Open access
JBJonathan M. Behar
Jonathan M. Behar
HCHui Men Selina Chin
Hui Men Selina Chin
SFSteve Fearn
Steve Fearn
JOJulian O.M. Ormerod
Julian O.M. Ormerod
JGJames Gamble
James Gamble
CRChristopher Aldo Rinaldi
Christopher Aldo Rinaldi
The objective of this study was to evaluate the cost-effectiveness of quadripolar versus bipolar cardiac resynchronization defibrillator therapy systems. Quadripolar left ventricular (LV) leads for cardiac resynchronization therapy reduce phrenic nerve stimulation (PNS) and are associated with reduced mortality compared with bipolar leads. A total of 606 patients received implants at 3 UK centers (319 Q, 287 B), between 2009 and 2014; mean follow-up was 879 days. Rehospitalization episodes were costed at National Health Service national tariff rates, and EQ-5D utility values were applied to heart failure admissions, acute coronary syndrome events, and mortality data, which were used to estimate quality-adjusted life-year differences over 5 years. Groups were matched with regard to age and sex. Patients with quadripolar implants had a lower rate of hospitalization than those with bipolar implants (42.6% vs. 55.4%; p = 0.002). This was primarily driven by fewer hospital readmissions for heart failure (51 [16%] vs. 75 [26.1%], respectively, for quadripolar vs. bipolar implants; p = 0.003) and generator replacements (9 [2.8%] vs. 19 [6.6%], respectively; p = 0.03). Hospitalization for suspected acute coronary syndrome, arrhythmia, device explantation, and lead revisions were similar. This lower health-care utilization cost translated into a cumulative 5-year cost saving for patients with quadripolar systems where the acquisition cost was <£932 (US $1,398) compared with bipolar systems. Probabilistic sensitivity analysis results mirrored the deterministic calculations. For the average additional price of £1,200 (US $1,800) over a bipolar system, the incremental cost-effective ratio was £3,692 per quality-adjusted life-year gained (US $5,538), far below the usual willingness-to-pay threshold of £20,000 (US $30,000). In a UK health-care 5-year time horizon, the additional purchase price of quadripolar cardiac resynchronization defibrillator therapy systems is largely offset by lower subsequent event costs up to 5 years after implantation, which makes this technology highly cost-effective compared with bipolar systems.

13 April 2023 in Arrhythmia and Electrophysiology Review
Verified
Journal Article
Open access
PDF file
NWNadeev Wijesuriya
Nadeev Wijesuriya
FVFelicity De Vere
Felicity De Vere
VMVishal Mehta
Vishal Mehta
SNSteven Niederer
Steven Niederer
CRChristopher A Rinaldi
Christopher A Rinaldi
JBJonathan M Behar
Jonathan M Behar
Leadless pacing is a rapidly growing field. Initially designed to provide right ventricular pacing for those who were contraindicated for conventional devices, the technology is growing to explore the potential benefit of avoiding long-term transvenous leads in any patient who requires pacing. In this review, we first examine the safety and performance of leadless pacing devices. We then review the evidence for their use in special populations, such as patients with high risk of device infection, patients on haemodialysis, and patients with vasovagal syncope who represent a younger population who may wish to avoid transvenous pacing. We also summarise the evidence for leadless cardiac resynchronisation therapy and conduction system pacing and discuss the challenges of managing issues, such as system revisions, end of battery life and extractions. Finally, we discuss future directions in the field, such as completely leadless cardiac resynchronisation therapy-defibrillator devices and whether leadless pacing has the potential to become a first-line therapy in the near future.