Jose Zavala

Jose Zavala

Auto-generated profile, based on publicly available information

Jose Zavala

MedTec BioLab Inc. , Hillsborough, North Carolina 27278, USA

Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
JZJose Zavala
Jose Zavala
AFAnastasia Freedman
Anastasia Freedman
JSJohn T. Szilagyi
John T. Szilagyi
IJIlona Jaspers
Ilona Jaspers
JWJohn Wambaugh
John Wambaugh
JRJulia E Rager
Julia E Rager
Air pollution consists of highly variable and complex mixtures recognized as major contributors to morbidity and mortality worldwide. The vast number of chemicals, coupled with limitations surrounding epidemiological and animal studies, has necessitated the development of new approach methods (NAMs) to evaluate air pollution toxicity. These alternative approaches include in vitro (cell-based) models, wherein toxicity of test atmospheres can be evaluated with increased efficiency compared to in vivo studies. In vitro exposure systems have recently been developed with the goal of evaluating air pollutant-induced toxicity; though the specific design parameters implemented in these NAMs-based studies remain in flux. This review aims to outline important design parameters to consider when using in vitro methods to evaluate air pollutant toxicity, with the goal of providing increased accuracy, reproducibility, and effectiveness when incorporating in vitro data into human health evaluations. This review is unique in that experimental considerations and lessons learned are provided, as gathered from first-hand experience developing and testing in vitro models coupled to exposure systems. Reviewed design aspects include cell models, cell exposure conditions, exposure chambers, and toxicity endpoints. Strategies are also discussed to incorporate in vitro findings into the context of in vivo toxicity and overall risk assessment.

8 April 2016 in Inhalation Toxicology
Verified
Journal Article
Closed access
PDF file
JZJose Zavala
Jose Zavala
BOBridget O’bRien
Bridget O’bRien
KLKim Lichtveld
Kim Lichtveld
KSKenneth G. Sexton
Kenneth G. Sexton
IRIvan Rusyn
Ivan Rusyn
WVWilliam Vizuete
William Vizuete
Context: EpiAirwayTM 3-D constructs are human-derived cell cultures of differentiated airway epithelial cells that may represent a more biologically relevant model of the human lung. However, limited information is available on their utility for exposures to air pollutants at the air-liquid interface (ALI). Objective: To assess the biological responses of EpiAirwayTM cells in comparison to the responses of A549 human alveolar epithelial cells after exposure to air pollutants at ALI. Methods: Cells were exposed to filtered air, 400 ppb of ozone (O3) or a photochemically aged Synthetic Urban Mixture (SynUrb54) consisting of hydrocarbons, nitrogen oxides, O3 and other secondary oxidation products for 4 h. Basolateral supernatants and apical washes were collected at 9 and 24 h post-exposure. We assessed cytotoxicity by measuring lactate dehydrogenase (LDH) release into the culture medium and apical surface. Interleukin 6 (IL-6) and interleukin 8 (IL-8) proteins were measured in the culture medium and in the apical washes to determine the inflammatory response after exposure. Results: Both O3 and SynUrb54 significantly increased basolateral levels of LDH and IL-8 in A549 cells. No significant changes in LDH and IL-8 levels were observed in the EpiAirwayTM cells, however, IL-6 in the apical surface was significantly elevated at 24 h after O3 exposure. Conclusion: LDH and IL-8 are robust endpoints for assessing toxicity in A549 cells. The EpiAirwayTM cells show minimal adverse effects after exposure suggesting that they are more toxicologically resistant compared to A549 cells. Higher concentrations or longer exposure times are needed to induce effects on EpiAirwayTM cells.

21 December 2012 in Atmospheric Chemistry and Physics
Verified
Journal Article
Open access
PDF file
SES. Ebersviller
S. Ebersviller
KLK. Lichtveld
K. Lichtveld
KSK. G. Sexton
K. G. Sexton
JZJ. Zavala
J. Zavala
YLYing-Hsuan Lin
Ying-Hsuan Lin
HJH. E. Jeffries
H. E. Jeffries
This is the first of a three-part study designed to demonstrate dynamic entanglements among gaseous organic compounds (VOC), particulate matter (PM), and their subsequent potential biological effects. We study these entanglements in increasingly complex VOC and PM mixtures in urban-like conditions in a large outdoor chamber. To the traditional chemical and physical characterizations of gas and PM, we added new measurements of biological effects, using cultured human lung cells as model indicators. These biological effects are assessed here as increases in cellular damage or expressed irritation (i.e., cellular toxic effects) from cells exposed to chamber air relative to cells exposed to clean air. The exposure systems permit virtually gas-only- or PM-only-exposures from the same air stream containing both gases and PM in equilibria, i.e., there are no extractive operations prior to cell exposure. Our simple experiments in this part of the study were designed to eliminate many competing atmospheric processes to reduce ambiguity in our results. Simple volatile and semi-volatile organic gases that have inherent cellular toxic properties were tested individually for biological effect in the dark (at constant humidity). Airborne mixtures were then created with each compound to which we added PM that has no inherent cellular toxic properties for another cellular exposure. Acrolein and p-tolualdehyde were used as model VOCs and mineral oil aerosol (MOA) was selected as a surrogate for organic-containing PM. MOA is appropriately complex in composition to represent ambient PM, and exhibits no inherent cellular toxic effects and thus did not contribute any biological detrimental effects on its own. Chemical measurements, combined with the responses of our biological exposures, clearly demonstrate that gas-phase pollutants can modify the composition of PM (and its resulting detrimental effects on lung cells). We observed that, even if the gas-phase pollutants are not considered likely to partition to the condensed phase, the VOC-modified-PM showed significantly more damage and inflammation to lung cells than did the original PM. Because gases and PM are transported and deposited differently within the atmosphere and the lungs, these results have significant consequences for a wide range of people. For example, current US policies for research and regulation of PM do not recognize this "effect modification" phenomena (NAS, 2004). These results present an unambiguous demonstration that – even in these simple mixtures – physical and thermal interactions alone can cause a modification of the distribution of species among the phases of airborne pollution mixtures that can result in a non-toxic phase becoming toxic due to atmospheric thermal processes only. Subsequent work (described in companion papers) extends the simple results reported here to systems with photochemical transformations of complex urban mixtures and to systems with diesel exhaust produced by different fuels.

1 January 2017 in Toxicology Research
Verified
Journal Article
Open access
PDF file
JZJose Zavala
Jose Zavala
RGRebecca Greenan
Rebecca Greenan
QKQ. Todd Krantz
Q. Todd Krantz
DDDavid M. DeMarini
David M. DeMarini
MHMark Higuchi
Mark Higuchi
PWPaul A White
Paul A White
Modifications to a VITROCELL exposure system were required to mitigate cytotoxicity caused by the absence of temperature and humidity control.

1 September 2014 in Chemico-Biological Interactions
Verified
Journal Article
Closed access
JZJose Zavala
Jose Zavala
KLKim Lichtveld
Kim Lichtveld
SESeth Ebersviller
Seth Ebersviller
JCJohnny L. Carson
Johnny L. Carson
GWGlenn W. Walters
Glenn W. Walters
WVWilliam Vizuete
William Vizuete

16 April 2018 in Inhalation Toxicology
Verified
Journal Article
Closed access
JZJose Zavala
Jose Zavala
ALAllen D. Ledbetter
Allen D. Ledbetter
DMDavid S. Morgan
David S. Morgan
LDLisa A. Dailey
Lisa A. Dailey
EPEarl Puckett
Earl Puckett
MHMark Higuchi
Mark Higuchi
A cell culture exposure system (CCES) was developed to expose cells established at an air–liquid interface (ALI) to volatile chemicals. We characterized the CCES by exposing indigo dye-impregnated filter inserts inside culture wells to 125 ppb ozone (O3) for 1 h at flow rates of 5 and 25 mL/min/well; the reaction of O3 with an indigo dye produces a fluorescent product. A 5-fold increase in fluorescence at 25 mL/min/well versus 5 mL/min/well was observed, suggesting higher flows were more effective. We then exposed primary human bronchial epithelial cells (HBECs) to 0.3 ppm acrolein for 2 h at 3, 5, and 25 mL/min/well and compared our results against well-established in vitro exposure chambers at the U.S. EPA’s Human Studies Facility (HSF Chambers). We measured transcript changes of heme oxygenase-1 (HMOX1) and interleukin-8 (IL-8), as well as lactate dehydrogenase (LDH) release, at 0, 1, and 24 h post-exposure. Comparing responses from HSF Chambers to the CCES, differences were only observed at 1 h post-exposure for HMOX1. Here, the HSF Chamber produced a ∼6-fold increase while the CCES at 3 and 5 mL/min/well produced a ∼1.7-fold increase. Operating the CCES at 25 mL/min/well produced a ∼4.5-fold increase; slightly lower than the HSF Chamber. Our biological results, supported by our comparison against the HSF Chambers, agree with our fluorescence results, suggesting that higher flows through the CCES are more effective at delivering volatile chemicals to cells. This new CCES will be deployed to screen the toxicity of volatile chemicals in EPA’s chemical inventories.