14 January 2021 in PLOS ONE
Background: The single-breath diffusing capacity of the lung for carbon monoxide (DLCO) interpretation needs the comparison of measured values to reference values. In 2017, the Global Lung Function Initiative published new reference values (GLI-2017) for DLCO, alveolar volume (VA) and transfer coefficient of the lung for carbon monoxide (KCO). We aimed to assess the applicability of GLI-2017 reference values for DLCO on a large population by comparing them to the European Community of Steel and Coal equations of 1993 (ECSC-93) widely used. Methods: In this retrospective study, spirometric indices, total lung capacity, DLCO, VA and KCO were measured in adults classified in 5 groups (controls, asthma, chronic bronchitis, cystic fibrosis, and interstitial lung diseases (ILD)). Statistical analysis comparing the 2 equations sets were stratified by sex. Results: 4180 tests were included. GLI-2017 z-scores of the 3 DLCO indices of the controls (n = 150) are nearer to 0 (expected value in a normal population) than ECSC-93 z-scores. All groups combined, in both genders, DLCO GLI-2017 z-scores and %predicted are significantly higher than ECSC z-scores and %predicted. In the ILD group, differences between the 2 equation sets depend on the DLCO impairment severity: GLI-2017 z-scores are higher than ECSC z-scores in patients with no or “mild” decrease in DLCO, but are lower in “moderate” or “severe” decrease. Conclusion: GLI-2017 reference values for DLCO are more suitable to our population and influence the diagnostic criteria and severity definition of several lung diseases.
1 February 2023 in Environmental Research
Although several studies have studied the relationship between occupational exposure to crystalline silica dust and respiratory mortality, few have examined the relationship with impairments in respiratory function and the exposure threshold triggering spirometric monitoring in exposed workers. The objective of the present study was to evaluate the impact of exposure to crystalline silica dust on respiratory function. We included 1428 male participants (aged 40 to 65) recruited from the French general population, at random from electoral rolls, in the cross-sectional ELISABET study and for whom data on forced expiratory flow-volume curve indices z-scores (calculated using the Global Lung Function Initiative 2012 equations) and exposure (via a questionnaire) were available. A cumulative exposure index (CEI) for crystalline silica dust (CEIsilica, expressed in mg.m-3.year) was calculated using the Matgéné occupational exposure matrix. 293 of the 1428 participants (20.52%) reported exposure to silica dust. We found that the adjusted z-scores for the forced expiratory volume in the first second/forced vital capacity (FEV1/FVC) ratio decreased significantly as CEIsilica increased. After adjustment, the adjusted z-scores for FEV1/FVC (β: -0.426 (95% confidence interval (CI): -0.792, -0.060) per 1 mg m-3.year increment) and the mean forced expiratory flow between 25 and 75% of the forced vital capacity (FEF25-75) (β: -0.552 (95% CI: -0.947, -0.157)) were significantly lower in the participants with CEIsilica ≥1 mg m-3.year than in non-exposed participants. The likelihoods of having airway obstruction (odds ratio (OR): 3.056 (95% CI: 1.107, 7.626)) or having an impaired FEF25-75 (OR: 4.305 (95% CI: 1.393, 11.79)) were also significantly higher in participants with CEIsilica ≥1 mg m-3.year. Our results emphasize the importance of spirometry-based monitoring in workers exposed to more than 1 mg m-3.year of crystalline silica dust, in order to identify small airway obstruction or airway obstruction as early as possible.
31 January 2024 in Journal of Occupational Medicine and Toxicology
NCNathalie Cherot-Kornobis
+3
Objective: To describe the proportions of subjects exposed to crystalline silica and the sectors of activity concerned between 1965 and 2010 in a sample of the general French population. Methods: We included 2942 participants aged 40 to 65 years, recruited at random from electoral rolls, from the French general population in the cross-sectional ELISABET study between 2011 and 2013. The proportions of subjects exposed to crystalline silica and their sectors of activity were determined on the basis of their career history and the use of the Matgéné job-exposure matrix. Results: In the total sample, occupational exposure to crystalline silica was found for 291 subjects (9.9%) between 1965 and 2010, with a predominance of men (20.2% of exposed subjects among men (282 out of 1394) versus 0.6% among women (9 out of 1548)). The highest proportion of participants exposed to crystalline silica was reached in 1980 with 6.1% and then decreases to 4.4% in 2010. Among men, the most frequently exposed sectors of activity were manufacture of basic metals (41.5% of exposed men (117 out of 282)), specialised construction activities (23.1% of exposed men (65 out of 282)) and construction of buildings (14.2% of exposed men (40 out of 282)). Conclusions: Although the proportion of workers exposed to crystalline silica has been decreasing since the 1980s, it is still significant at least until 2010, particularly in the construction sector, and further research is needed to improve the monitoring of workers who are or have been exposed to crystalline silica.
8 February 2025 in Respiratory Medicine
SDSilvia Demoulin-Alexikova
Silvia Demoulin-Alexikova
In 2021, the Global Lung Function Initiative (GLI) has published new reference equations for static lung volumes (GLI-2021). Many learned societies recommend the use of GLI reference values for interpreting pulmonary function tests (PFT), while pointing out the need for clinicians to be aware of the consequences for their routine practice. We aimed to compare the GLI-2021 reference values and the 1993 European Coal and Steel Community (ECSC) standards on the interpretation of static lung volume data in patients with a probable static hyperinflation or a probable restrictive ventilatory disorder. We analyzed plethysmographic PFT data from 2 groups of patients: a group of patients with symptoms compatible with chronic bronchitis (CB) and a group of patients with symptoms compatible with interstitial lung disease (ILD). We investigated discrepancies in the evaluations of static lung volumes when using the ECSC vs. the GLI-2021 reference values. 2897 sets of PFT results (including 1598 in men) were included. In the CB group, the proportion of hyperinflation was higher for both sexes with the GLI-2021 standards. In the ILD group, the proportion of restrictive ventilatory disorders was higher in women but lower in men with the GLI-2021 standards. A move from use of the ECSC standards for static lung volumes to the GLI-2021 standards might lead to a higher estimated proportion of hyperinflation (particularly in participants with CB), together with changes in the proportion of restrictive ventilatory disorders (a lower value in men and a higher value in women with ILD).