Stuart Lacy

Stuart Lacy

Auto-generated profile, based on publicly available information

Stuart Lacy

Wolfson Atmospheric Chemistry Laboratories, Department of Chemistry, University of York, York, YO10 5DD, UK

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
3 April 2023 in Nature Communications
Verified
Journal Article
Open access
PDF file
LWLaura Wiggins
Laura Wiggins
ALAlice Lord
Alice Lord
KMKillian L. Murphy
Killian L. Murphy
SLStuart E. Lacy
Stuart E. Lacy
POPeter O'Toole
Peter O'Toole
JWJulie Wilson
Julie Wilson
With phenotypic heterogeneity in whole cell populations widely recognised, the demand for quantitative and temporal analysis approaches to characterise single cell morphology and dynamics has increased. We present CellPhe, a pattern recognition toolkit for the unbiased characterisation of cellular phenotypes within time-lapse videos. CellPhe imports tracking information from multiple segmentation and tracking algorithms to provide automated cell phenotyping from different imaging modalities, including fluorescence. To maximise data quality for downstream analysis, our toolkit includes automated recognition and removal of erroneous cell boundaries induced by inaccurate tracking and segmentation. We provide an extensive list of features extracted from individual cell time series, with custom feature selection to identify variables that provide greatest discrimination for the analysis in question. Using ensemble classification for accurate prediction of cellular phenotype and clustering algorithms for the characterisation of heterogeneous subsets, we validate and prove adaptability using different cell types and experimental conditions.

16 September 2013 in IEEE Transactions on Evolutionary Computation
Verified
Journal Article
Closed access
MLMichael A. Lones
Michael A. Lones
SSStephen L. Smith
Stephen L. Smith
Jane E. AltyJane E. Alty
Jane E. Alty
SLStuart E. Lacy
Stuart E. Lacy
KPKatherine L. Possin
Katherine L. Possin
ATAndy M. Tyrrell
Andy M. Tyrrell
Parkinson's disease is a debilitating neurological condition that affects approximately 1 in 500 people and often leads to severe disability. To improve clinical care, better assessment tools are needed that increase the accuracy of differential diagnosis and disease monitoring. In this paper, we report how we have used evolutionary algorithms to induce classifiers capable of recognizing the movement characteristics of Parkinson's disease patients. These diagnostically relevant patterns of movement are known to occur over multiple time scales. To capture this, we used two different classifier architectures: sliding-window genetic programming classifiers, which model over-represented local patterns that occur within time series data, and artificial biochemical networks, computational dynamical systems that respond to dynamical patterns occurring over longer time scales. Classifiers were trained and validated using movement recordings of 49 patients and 41 age-matched controls collected during a recent clinical study. By combining classifiers with diverse behaviors, we were able to construct classifier ensembles with diagnostic accuracies in the region of 95%, comparable to the accuracies achieved by expert clinicians. Further analysis indicated a number of features of diagnostic relevance, including the differential effect of handedness and the over-representation of certain patterns of acceleration.

1 March 2018 in Artificial Intelligence in Medicine
Verified
Journal Article
Open access
SLStuart E. Lacy
Stuart E. Lacy
SSStephen L. Smith
Stephen L. Smith
MLMichael A. Lones
Michael A. Lones
Despite having notable advantages over established machine learning methods for time series analysis, reservoir computing methods, such as echo state networks (ESNs), have yet to be widely used for practical data mining applications. In this paper, we address this deficit with a case study that demonstrates how ESNs can be trained to predict disease labels when stimulated with movement data. Since there has been relatively little prior research into using ESNs for classification, we also consider a number of different approaches for realising input-output mappings. Our results show that ESNs can carry out effective classification and are competitive with existing approaches that have significantly longer training times, in addition to performing similarly with models employing conventional feature extraction strategies that require expert domain knowledge. This suggests that ESNs may prove beneficial in situations where predictive models must be trained rapidly and without the benefit of domain knowledge, for example on high-dimensional data produced by wearable medical technologies. This application area is emphasized with a case study of Parkinson's disease patients who have been recorded by wearable sensors while performing basic movement tasks.

13 July 2022 in Atmospheric Measurement Techniques
Verified
Journal Article
Open access
PDF file
SDSebastian Diez
Sebastian Diez
SLStuart E. Lacy
Stuart E. Lacy
TBThomas Bannan
Thomas Bannan
MFMichael Flynn
Michael Flynn
TGTom Gardiner
Tom Gardiner
PEPete M. Edwards
Pete M. Edwards
When making measurements of air quality, having a reliable estimate of the measurement uncertainty is key to assessing the information content that an instrument is capable of providing, and thus its usefulness in a particular application. This is especially important given the widespread emergence of low cost sensors (LCS) to measure air quality. To do this, end users need to clearly identify the data requirements a priori and design quantifiable success criteria by which to judge the data. All measurements suffer from errors, with the degree to which these errors impact the accuracy of the final data often determined by our ability to identify and correct for them. The advent of LCS has provided a challenge in that many error sources show high spatial and temporal variability, making laboratory derived corrections difficult. Characterising LCS performance thus currently depends primarily on colocation studies with reference instruments, which are very expensive and do not offer a definitive solution but rather a glimpse of LCS performance in specific conditions over a limited period of time. Despite the limitations, colocation studies do provide useful information on measurement device error structure, but the results are non-trivial to interpret and often difficult to extrapolate to future device performance. A problem that obscures much of the information content of these colocation performance assessments is the exacerbated use of global performance metrics (R2, RMSE, MAE, etc.). Colocation studies are complex and time-consuming, and it is easy to fall into the temptation to only use these metrics when trying to define the most appropriate sensor technology to subsequently use. But the use of these metrics can be limited, and even misleading, restricting our understanding of the error structure and therefore the measurements' information content. In this work, the nature of common air pollution measurement errors is investigated, and the implications they have on traditional metrics and other empirical, potentially more insightful approaches to assess measurement performance. With this insight we demonstrate the impact these errors can have on measurements, using a selection of LCS deployed alongside reference measurements as part of the QUANT project, and discuss the implications this has on device end use.

26 June 2024 in Atmospheric Measurement Techniques
Verified
Journal Article
Open access
PDF file
SDSebastian Diez
Sebastian Diez
SLStuart Lacy
Stuart Lacy
HCHugh Coe
Hugh Coe
JUJosefina Urquiza
Josefina Urquiza
MPMax Priestman
Max Priestman
PEPete M. Edwards
Pete M. Edwards
In times of growing concern about the impacts of air pollution across the globe, lower-cost sensor technology is giving the first steps in helping to enhance our understanding and ability to manage air quality issues, particularly in regions without established monitoring networks. While the benefits of greater spatial coverage and real-time measurements that these systems offer are evident, challenges still need to be addressed regarding sensor reliability and data quality. Given the limitations imposed by intellectual property, commercial implementations are often “black boxes”, which represents an extra challenge as it limits end users' understanding of the data production process. In this paper we present an overview of the QUANT (Quantification of Utility of Atmospheric Network Technologies) study, a comprehensive 3-year assessment across a range of urban environments in the United Kingdom, evaluating 43 sensor devices, including 119 gas sensors and 118 particulate matter (PM) sensors, from multiple companies. QUANT stands out as one of the most comprehensive studies of commercial air quality sensor systems carried out to date, encompassing a wide variety of companies in a single evaluation and including two generations of sensor technologies. Integrated into an extensive dataset open to the public, it was designed to provide a long-term evaluation of the precision, accuracy and stability of commercially available sensor systems. To attain a nuanced understanding of sensor performance, we have complemented commonly used single-value metrics (e.g. coefficient of determination, R2; root mean square error, RMSE; mean absolute error, MAE) with visual tools. These include regression plots, relative expanded uncertainty (REU) plots and target plots, enhancing our analysis beyond traditional metrics. This overview discusses the assessment methodology and key findings showcasing the significance of the study. While more comprehensive analyses are reserved for future detailed publications, the results shown here highlight the significant variation between systems, the incidence of corrections made by manufacturers, the effects of relocation to different environments and the long-term behaviour of the systems. Additionally, the importance of accounting for uncertainties associated with reference instruments in sensor evaluations is emphasised. Practical considerations in the application of these sensors in real-world scenarios are also discussed, and potential solutions to end-user data challenges are presented. Offering key information about the sensor systems' capabilities, the QUANT study will serve as a valuable resource for those seeking to implement commercial solutions as complementary tools to tackle air pollution.

1 April 2013
Verified
Conference Paper
Closed access
MLMichael A. Lones
Michael A. Lones
Jane E. AltyJane E. Alty
Jane E. Alty
SLStuart E. Lacy
Stuart E. Lacy
DJD. R. Stuart Jamieson
D. R. Stuart Jamieson
KPKate L. Possin
Kate L. Possin
SSStephen L. Smith
Stephen L. Smith
We describe the use of a genetic programming system to induce classifiers that can discriminate between Parkinson's disease patients and healthy age-matched controls. The best evolved classifer achieved an AUC of 0.92, which is comparable with clinical diagnosis rates. Compared to previous studies of this nature, we used a relatively large sample of 49 PD patients and 41 controls, allowing us to better capture the wide diversity seen within the Parkinson's population. Classifiers were induced from recordings of these subjects' movements as they carried out repetitive finger tapping, a standard clinical assessment for Parkinson's disease. For ease of interpretability, we used a relatively simple window-based classifier architecture which captures patterns that occur over a single tap cycle. Analysis of window matches suggested the importance of peak closing deceleration as a basis for classification. This was supported by a follow-up analysis of the data set, showing that closing deceleration is more discriminative than features typically used in clinical assessment of finger tapping.