A new energy management framework for multi-microgrid (MMG) systems composed of high renewable energy sources (RES) is proposed in this paper. In traditional energy management system (EMS), battery energy storage system (BESS) is only considered in a single microgrid (MG) optimization model, which leads to underutilization of storage devices and waste of resources. Considering the advantages of local consumption of RES, this paper develops a hierarchical multi-agent energy management strategy. A two-step model aiming at maximizing the usage of RES is established to help determine the strategy. In the first step, the strategy is developed to maximize the local consumption of RES based on the demand response programs (DRP) and BESS within the independent MG. In the second step, the community BESS and BESSs are used to share the RES of multiple MGs for increasing the utilization ratio of RES. Simultaneously, the output of each controllable distributed generator (CDG) and the transaction with power grid are determined through a distributed adjustable power generation plan query library (DGPS). Moreover, the simulation with a three-MG system proves that the strategy can effectively increase the utilization ratio of RES and reduce the transaction with power grid compared to the traditional strategy.
This paper proposes a new method to locate the partial discharge (PD) sources inside the high-voltage power transformers with ultra-high frequency (UHF) sensors, based on the time difference of arrival (TDOA) database. A TDOA database includes the TDOA information of possible PD sources inside a power transformer, which is established under the construction of the system of the tested power transformer and the high accuracy of the minimum distance between a possible PD source and a UHF sensor. We employ the tangent transmission model of PD signals and the shortest path algorithm to solve the distance problem in case of an obstacle obstructing the transmission of PD signals. In order to verify the feasibility and accuracy of this new TDOA database method, we carry out two experiments. One experiment was conducted with a 110kV power transformer and the other was carried out with a platform for PD of electric power equipment. The experimental research results which are composed of location coordinates, transmission path and TDOA information indicate that the TDOA database method can locate single PD source as well as multiple PD sources simultaneously with the location error less than 0.3m.