29 August 2013 in IEEE Transactions on Medical Imaging
Detection of intrinsic or extrinsically administered chromophores and photo-absorbing nanoparticles has been achieved by multi-spectral optoacoustic tomography (MSOT). The detection sensitivity of MSOT depends not only on the signal to noise ratio considerations, as in conventional optoacoustic (photoacoustic) tomography implementations, but also on the ability to resolve the molecular targets of interest from the absorbing tissue background by means of spectral unmixing or sub-pixel detection methods. However, it is not known which unmixing methods are optimally suited for the characteristics of multispectral optoacoustic images. In this work we investigated the performance of different sub-pixel detection methods, typically used in remote sensing hyperspectral imaging, within the context of MSOT. A quantitative comparison of the different algorithmic approaches was carried out in an effort to identify methods that operate optimally under the particulars of molecular imaging applications. We find that statistical sub-pixel detection methods can demonstrate a unique detection performance with up to five times enhanced sensitivity as compared to linear unmixing approximations, under the condition that the optical agent of interest is sparsely present within the tissue volume, as common when using targeted agents and reporter genes.
20 March 2007 in Circulation
Background—
Fluorescence imaging of the heart is currently limited to invasive ex vivo or in vitro applications. We hypothesized that the adaptation of advanced transillumination and tomographic techniques would allow noninvasive fluorescence images of the heart to be acquired in vivo and be coregistered with in vivo cardiac magnetic resonance images.
Methods and Results—
The uptake of the magnetofluorescent nanoparticle CLIO-Cy5.5 by macrophages in infarcted myocardium was studied. Ligation of the left coronary artery was performed in 12 mice and sham surgery in 7. The mice were injected, 48 hours after surgery, with 3 to 20 mg of iron per kilogram of CLIO-Cy5.5. Magnetic resonance imaging and fluorescence molecular tomography were performed 48 hours later. An increase in magnetic resonance imaging contrast-to-noise ratio, indicative of myocardial probe accumulation, was seen in the anterolateral walls of the infarcted mice but not in the sham-operated mice (23.0±2.7 versus 5.43±2.4; P <0.01). Fluorescence intensity over the heart was also significantly greater in the fluorescence molecular tomography images of the infarcted mice (19.1±5.2 versus 5.3±1.4; P <0.05). The uptake of CLIO-Cy5.5 by macrophages infiltrating the infarcted myocardium was confirmed by fluorescence microscopy and immunohistochemistry.
Conclusions—
Noninvasive imaging of myocardial macrophage infiltration has been shown to be possible by both fluorescence tomography and magnetic resonance imaging. This could be of significant value in both the research and clinical settings. The techniques developed could also be used to image other existing fluorescent and magnetofluorescent probes and could significantly expand the role of fluorescence imaging in the heart.
26 January 2007 in Optics Letters
Optics InfoBase is the Optical Society's online library for flagship journals, partnered and copublished journals, and recent proceedings from OSA conferences.
3 February 2011 in Optics Express
Multispectral optoacoustic (photoacoustic) tomography (MSOT) is a hybrid modality that can image through several millimeters to centimeters of diffuse tissues, attaining resolutions typical of ultrasound imaging. The method can further identify tissue biomarkers by decomposing the spectral contributions of different photo-absorbing molecules of interest. In this work we investigate the performance of blind source unmixing methods and spectral fitting approaches in decomposing the contributions of fluorescent dyes from the tissue background, based on MSOT measurements in mice. We find blind unmixing as a promising method for accurate MSOT decomposition, suitable also for spectral unmixing in fluorescence imaging. We further demonstrate its capacity with temporal unmixing on real-time MSOT data obtained in-vivo for enhancing the visualization of absorber agent flow in the mouse vascular system.
1 January 2008 in Journal of Biomedical Optics
The discovery of new fluorescent proteins (FPs) that emit in the far-red part of the spectrum, where light absorption from tissue is significantly lower than in the visible, offers the possibility for noninvasive biological interrogation at the entire organ or small animal level in vivo. The performance of FPs in deep-tissue imaging depends not only on their optical characteristics, but also on the wavelength-dependent tissue absorption and the depth of the fluorescence activity. To determine the optimal choice of FP and illumination wavelength, we compared the performance of five of the most promising FPs: tdTomato, mCherry, mRaspberry, mPlum, and Katushka. We experimentally measured the signal strength through mice and employed theoretical predictions to obtain an understanding of the performance of different illumination scenarios, especially as they pertain to tomographic imaging. It was found that the appropriate combination of red-shifted proteins and illumination wavelengths can improve detection sensitivity in small animals by at least two orders of magnitude compared with green FP. It is also shown that the steep attenuation change of the hemoglobin spectrum around the 600-nm range may significantly affect the detection sensitivity and, therefore, necessitates the careful selection of illumination wavelengths for optimal imaging performance.
8 March 2014 in Molecular Imaging and Biology