Hossein Mokhtari

Hossein Mokhtari

Auto-generated profile, based on publicly available information

Hossein Mokhtari

Department of Electrical Engineering, Sharif University of Technology, Tehran, Iran

Research Focus & Metrics

Academic Career Length

21Years (2006-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
4 June 2018 in IEEE Transactions on Power Delivery
Verified
Journal Article
Closed access
SZSeyed Fariborz Zarei
Seyed Fariborz Zarei
HMHossein Mokhtari
Hossein Mokhtari
MGMohamad Amin Ghasemi
Mohamad Amin Ghasemi
Frede BlaabjergFrede Blaabjerg
Frede Blaabjerg
Medium power distributed energy resources (DERs) are commonly connected to medium voltage distribution systems via voltage source converters (VSCs). Several guidelines and standards have been developed to establish the needed criteria and requirements for DERs interconnections. In this respect, it is preferred to reinforce the VSC fault ride through (FRT) capability, which considerably minimizes the DG outage period and reconnection time and results in a resilient system against short circuits. Considering the significant number of asymmetrical faults in distribution systems, the VSC response in such conditions must be investigated, and consequently, its FRT capability must be reinforced. In this paper firstly a comprehensive review on existing FRT methods has been presented and discussed. Accordingly, an adaptive virtual impedance-based voltage reference generation method is proposed, which enhances the VSC behavior under short circuits and increases the VSC FRT capability. Also, a fast sinusoidal current reference limiter is proposed to improve the performance. To evaluate the performance of the proposed scheme, state space analysis is presented, and a complete set of simulations is performed in PSCAD/EMTDC environment. Also, a comparison with the conventional method is presented.

8 June 2017 in IEEE Transactions on Smart Grid
Verified
Journal Article
Closed access
Saeed PeyghamiSaeed Peyghami
Saeed Peyghami
HMHossein Mokhtari
Hossein Mokhtari
Frede BlaabjergFrede Blaabjerg
Frede Blaabjerg
Applying conventional dc-voltage based droop approaches for hybrid ac/dc microgrids interconnected by a single interlinking converter (IC) can properly manage the power flow among ac and dc subgrids. However, due to the effect of line resistances, these approaches may create a circulating power as well as overstressing the ICs in the case of employing multiple ICs for interconnecting the ac and dc subgrids. This paper proposes an autonomous power sharing approach for hybrid microgrids interconnected through multiple ICs by introducing a superimposed frequency in the dc subgrid. Hence, a suitable droop approach is presented to manage the power among the dc and ac sources as well as ICs. The outcomes are proportional power sharing, preventing circulating power and overstressing the ICs as well as acceptable dc voltage regulation. Furthermore, the maximum transferred power by the ICs can be improved by employing the proposed approach. The effectiveness of the proposed approach is evaluated by simulation.

4 October 2019 in IEEE Transactions on Energy Conversion
Verified
Journal Article
Closed access
SZSeyed Fariborz Zarei
Seyed Fariborz Zarei
HMHossein Mokhtari
Hossein Mokhtari
MGMohamad Amin Ghasemi
Mohamad Amin Ghasemi
Saeed PeyghamiSaeed Peyghami
Saeed Peyghami
Pooya DavariPooya Davari
Pooya Davari
Frede BlaabjergFrede Blaabjerg
Frede Blaabjerg
This paper proposes a new control scheme to eliminate the $3^{\text{rd}}$ harmonic in the output currents of grid-following inverters under unbalanced grid conditions. Unbalanced grids adversely affect the performance of grid-following inverters due to the oscillations appearing on the DC-link voltage with a frequency twice the line frequency. The paper is based on instantaneous active reactive control (IARC) technique due to its advantages over other existing methods. However, the presence of severe asymmetrical $3^{\text{rd}}$ harmonic distortions in the inverter output currents is the main challenge with IARC method, which impairs the power quality requirements. This paper enhances the IARC scheme by proposing a $3^{\text{rd}}$ harmonic elimination approach by adopting a current reference generation method using the symmetric sequence components concept. Furthermore, the proposed scheme complies with the grid code requirements by injecting the requested reactive current. Finally, the proposed approach is evaluated by theoretical and simulation analysis and validated experimentally using a hardware setup.

25 December 2019 in IEEE Journal of Emerging and Selected Topics in Power Electronics
Verified
Journal Article
Closed access
SZSeyed Fariborz Zarei
Seyed Fariborz Zarei
HMHossein Mokhtari
Hossein Mokhtari
Frede BlaabjergFrede Blaabjerg
Frede Blaabjerg
This paper proposes a fault detection and protection strategy for islanded inverter-based microgrids (IBMGs). Reliable and accurate protection is one of the main challenges in the proliferation of modern microgrids (MGs). Considering the limited fault current of the voltage-frequency controlled inverter-based distributed energy resources (VF-IBDERs), the protection is more challenging in islanded IBMGs. In this regard, the control scheme of VF-IBDER with a current limiting strategy plays an important role. Due to the limited fault currents close to the converter nominal current, the conventional fault detection methods do not work properly. In addition, bi-directional fault currents worsen protection coordination. In this paper, first, an analytical sequence network modeling for VF-IBDERs is derived to specify their behavior under fault conditions. Then, a voltage-restrained negative-sequence resistance-based fault detection approach is proposed, which is based on the derived sequence networks. This quantity inherently detects the fault and its direction and is independent from the fault current magnitude. The proposed feature can be employed in both conventional and communication-assisted coordination strategies. Also, a protection coordination strategy based on definite-time grading approach is employed. Finally, the performance of the proposed scheme is demonstrated by applying different faults in a test MG in PSCAD/EMTDC environment.

15 April 2019 in IEEE Transactions on Smart Grid
Verified
Journal Article
Closed access
Saeed PeyghamiSaeed Peyghami
Saeed Peyghami
Pooya DavariPooya Davari
Pooya Davari
HMHossein Mokhtari
Hossein Mokhtari
Frede BlaabjergFrede Blaabjerg
Frede Blaabjerg
Power sharing control among grid forming DC sources employing a conventional voltage droop approach meets inaccurate load sharing and unacceptable voltage regulation performance. Thereby, communication-based secondary and supervisory controllers have been presented to overcome the aforementioned issues. Furthermore, with the aim of eliminating communication system, frequency-based droop approaches have been introduced for low voltage DC grids where the frequency of the superimposed AC signal onto the DC voltage is proportional to the output power. However, in reality, DC grid structures can be applied to medium and high voltage applications with different X/R ratios. This paper generalizes the frequency-based droop scheme for DC microgrids with different low, medium and high X/R ratios. Obtained simulation and experiment results demonstrate the effectiveness of the proposed control method.

25 July 2017 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
Saeed PeyghamiSaeed Peyghami
Saeed Peyghami
HMHossein Mokhtari
Hossein Mokhtari
Frede BlaabjergFrede Blaabjerg
Frede Blaabjerg
In this paper a novel droop approach for autonomous power management in low voltage dc microgrids based on a master-slave concept is presented. Conventional voltage-based droop approaches suffer from poor power sharing due to line resistance effects on a virtual resistance, which is solved a by introducing a communication system to increase the current sharing accuracy. In this paper, a virtual frequency is superimposed by the master units, and slave units determine their output power according to the corresponding frequency-based droop characteristics. Unlike the voltage-droop methods, the proposed virtual frequency-droop approach can be applied for proportional power management among the energy units and loads in the microgrid without utilizing any extra communication system. The effectiveness of the proposed scheme is evaluated by simulations and further validated by experiments.