In this report, a hand-held impulse-radar breast cancer detector is presented and the detectability of malignant breast tumors is demonstrated in the clinical test at Hiroshima University Hospital, Hiroshima, Japan. The core functional parts of the detector consist of 65-nm technology complementary metal-oxide-semiconductor (CMOS) integrated circuits covering the ultrawideband width from 3.1 to 10.6 GHz, which enable the generation and transmission of Gaussian monocycle pulse (GMP) with the pulse width of 160 ps and single port eight throw (SP8T) switching matrices for controlling the combination of 4 × 4 cross-shaped dome antenna array. The detector is designed to be placed on the breast with the patient in the supine position. The detectability of malignant tumors is confirmed in excised breast tissues after total mastectomy surgery. The three-dimensional positions of the tumors in the imaging results are consistent with the results of histopathology analysis. The clinical tests are conducted by a clinical doctor for five patients at the hospital. The malignant tumors include invasive ductal carcinoma (IDC) and ductal carcinoma in situ (DCIS). The final confocal imaging results are consistent with those of Magnetic Resonance Imaging (MRI), demonstrating the feasibility of the hand-held impulse-radar detector for malignant breast tumors.
Emerging evidence indicates that small RNAs, including microRNAs (miRNAs) and their isoforms (isomiRs), and transfer RNA fragments (tRFs), are differently expressed in breast cancer (BC) and can be detected in blood circulation. Circulating small RNAs and small RNAs in extracellular vesicles (EVs) have emerged as ideal markers in small RNA‐based applications for cancer detection. In this study, we first undertook small RNA sequencing to assess the expression of circulating small RNAs in the serum of BC patients and cancer‐free individuals (controls). Expression of 3 small RNAs, namely isomiR of miR‐21‐5p (3′ addition C), miR‐23a‐3p and tRF‐Lys (TTT), was significantly higher in BC samples and was validated by small RNA sequencing in an independent cohort. Our constructed model using 3 small RNAs showed high diagnostic accuracy with an area under the receiver operating characteristic curve of 0.92 and discriminated early‐stage BCs at stage 0 from control. To test the possibility that these small RNAs are released from cancer cells, we next examined EVs from the serum of BC patients and controls. Two of the 3 candidate small RNAs were identified, and shown to be abundant in EVs of BC patients. Interestingly, these 2 small RNAs are also more abundantly detected in culture media of breast cancer cell lines (MCF‐7 and MDA‐MB‐231). The same tendency in selective elevation seen in total serum, serum EV, and EV derived from cell culture media could indicate the efficiency of this model using total serum of patients. These findings indicate that small RNAs serve as significant biomarkers for BC detection.
Radar-based microwave imaging is a promising technique for multiple medical applications such as breast health monitoring, breast cancer detection, ablation monitoring, and chemotherapy monitoring. In our previous work, a hand-held multistatic CMOS impulse-radar detector was developed. It was designed to be placed directly on the patient in supine position without a coupling medium. In the radar-based microwave breast imaging, the surface clutters, which are generated from skin reflection, imperfect contacts and antenna coupling, deteriorate the imaging quality. This paper proposes a two-stage rotational (TSR) clutter suppression method for the multistatic rotational configuration of the radar-detector. It consists of a signal selection stage and an adaptive filtering stage. The novelty of the proposed method is that a prior constraint using L2 regularization is introduced to facilitate the filtering. Meanwhile, the antenna and channel variations are considered in the signal selection. The performance of the proposed method is verified in experiments with different surface conditions and patient trial. The results demonstrated that the proposed method is effective in suppressing the surface clutters and improving the image quality.
17 December 2018 in IEEE Transactions on Biomedical Engineering
The objective of this study is to investigate the detectability of breast tumors having various histological types in excised breast tissues of total mastectomy. The tumor images measured by a portable impulse-radio-ultra-wideband (IR-UWB)-radar-based breast cancer detector are compared with both pathological images and images of dedicated breast positron emission tomography (DbPET). It is found that the detector can detect invasive-ductal-carcinomas (IDC) and extensive intra-ductal component (EIC) in the dense breast. The density of the breast has correlation to the effective permittivity derived from the reconstructed confocal images. The results show that the IR-UWB-radar-based breast cancer detector has a potential as a portable modality for early-stage breast cancer screening.