1 April 2012 in Measurement
9 May 2018 in IEEE Transactions on Instrumentation and Measurement
Photoplethysmographic (PPG) measurements are susceptible to motion artifacts (MA) due to movement of the peripheral body parts. In this paper, we present a new approach to identify the MA corrupted PPG beats and then rectify the beat morphology using artificial neural network (ANN). Initially, beat quality assessment was done to identify the clean PPG beats by a pretrained feedback ANN to generate a reference beat template for each person. The PPG data were decomposed using principal component analysis (PCA) and reconstructed using fixed energy retention. A weight coefficient was assigned for each PPG sample in such a way that when they are multiplied, the modified beat morphology matches the reference template. A particle swarm optimization-based technique was utilized to select the best weight vector coefficients to tune another feedback ANN, fed with a set of significant features generated by an auto-encoder from PCA reconstructed data. For real-time implementation, this pretrained ANN was operated in feed-forward mode to directly generate the weight vectors for any subsequent measurements of PPG. The method was validated with PPG data collected from 55 human subjects. An average root-mean-square error of 0.28 and signal-to-noise ratio improvement of 14.54 dB were obtained, with an average improvement of 36% and 47% measurement accuracies on crest time and systolic to diastolic peak height ratio, respectively. With the IEEE Signal Processing Cup 2015 challenge database, Pearson's correlation coefficient between PPG-estimated and ECG-derived heart rates was 0.990. The proposed method can be useful for personal health monitoring applications.
1 November 2010 in Measurement
10 December 2020 in IEEE Transactions on Instrumentation and Measurement
Non-invasive monitoring of respiratory activity is an emerging research area in biomedical health monitoring. This paper describes a neural network-based model, i-PRExT, intelligent Photoplethysmography derived Respiration signal Extraction, and Tracking. Here, an ensemble empirical mode decomposition (EEMD) is used to select the appropriate intrinsic mode functions (IMF) through filtering in the respiration band and reconstruct by a linear weighted sum to obtain the photoplethysmography derived respiration (PDR) signal. The weight factors are derived by a multilayer perceptron neural network (MLPNN) fed with respiratory induced amplitude variation (RIAV) features extracted by a deep autoencoder (DAE). The tracking of respiration rate (RR) is done by an adaptive filter-based predictor. i-PRExT was tested and validated with BIDMC dataset under PhysioNet and 30 volunteers’ data collected under resting condition. The PDRs achieved over 90% correlation and low error (NRMSE~0.2) with reference respiration signal, while RRs have almost 100% correlation even under motion artifact (MA) corrupted PPG. The PDR shows improved performance, while respiratory rate (RR) tracking outperforms the published research on respiration signal extraction based on PPG.
27 October 2014 in IEEE Transactions on Instrumentation and Measurement
Photoplethysmogram (PPG) signal can provide vital diagnostic information on cardiovascular functions of the human body. In this paper, a lossless, real-time compression technique based on combination of second-order delta and the Huffman encoding is proposed for the PPG signal. The algorithm was validated with 10-bit quantized PPG data collected from multiparameter intelligent monitoring in intensive care-II database under Physionet and healthy volunteers using Biopac Systems at 125-Hz sampling frequency. Using a block size of 48 samples, the average compression ratio, percentage root-mean-squared difference (PRD), and PRD normalized achieved was 2.223, 0.127, and 0.187 respectively with 30 sets of volunteers' data. Three prime clinical features, systolic amplitude, systolic upstroke time, and pulse width from the decompressed PPG waveform were evaluated with less than 1% distortion on the diagnostic measures. A study was also done to estimate the compression efficiency for different sample block size, wave morphology, and sampling frequency of raw data. The low time complexity of the proposed algorithm encourages its implementation for development low-cost real-time PPG measurement application in patient monitoring.