The strongest event of geomagnetically induced currents (GIC) detected by the North‐West Russian GIC network occurred during the main phase of the magnetic storm on 28 and 29 June 2013. Extremely high value, 120 A, was recorded in the 330 kV transformers on Kola Peninsula in the 04–07 magnetic local time (MLT) sector. The Defense Meteorological Satellite Program (DMSP) spacecraft took a sequence of ultraviolet (UV) auroral images in the southern hemisphere and observed multiple omega bands. The ionospheric equivalent electric currents based on the International Monitor for Auroral Geomagnetic Effects (IMAGE) magnetometer network reveal a sequence of current vortex pairs moving eastward with the speed of 0.5–2.5 km/s that fits to the electrodynamics scheme of omega bands. Although the temporal variations of the associated current system are slow, the omega bands can be responsible for strong magnetic variations and GIC due to fast propagations of currents in the azimuthal direction.
27 May 2019 in Journal of Space Weather and Space Climate
Geomagnetically induced currents (GICs) represent a significant challenge for society on a stable electricity supply. Space weather activates global electromagnetic and plasma processes in the near-Earth environment, however, the highest risk of GICs is related not directly to those processes with enormous energy yield, but too much weaker, but fast, processes. Here we consider several typical examples of such fast processes and their impact on power transmission lines in the Kola Peninsula and in Karelia: interplanetary shocks; traveling convection vortices; impulses embedded in substorms; and irregular Pi3 pulsations. Geomagnetic field variability is examined using data from the IMAGE (International Monitor for Auroral Geomagnetic Effects) magnetometer array. We have confirmed that during the considered impulsive events the ionospheric currents fluctuate in both the East-West and North-South directions, and they do induce GIC in latitudinally extended electric power line. It is important to reveal the fine structure of fast geomagnetic variations during storms and substorms not only for a practical point of view but also for a fundamental scientific view.
The St. Patrick’s Day geomagnetic storm on March 17, 2015, has been chosen by the space community for synergetic analysis to build a more comprehensive picture of the storm’s origin and evolution. This storm had an unusually long (~ 17 h) main phase. During this period, many substorm-like activations occurred. These activations resulted in bursts of geomagnetically induced currents (GICs) in power lines on the Kola peninsula. To examine the substorm activations in more detail, we apply various data processing techniques for the world-wide array of magnetometers: the virtual magnetograms, magnetic latitude–local time (MLT) snapshots, and magnetic keograms. These techniques are simple tools that are supplementary to more advanced facilities developed for the analysis of SuperDARN, IMAGE, and CARISMA arrays. We compare the global spatial localization and time evolution of the geomagnetic X-component disturbance and magnetic field variability measured by the Hilbert transform of time derivative dB/dt. The latitude-MLT mapping of these magnitudes shows that very often a region with highest magnetic variability does not overlap with a substorm “epicenter” but is shifted to its poleward or equatorward boundaries. Highest variability of the geomagnetic field, and consequently intense GICs, are caused by medium-scale fast varying structures. There is no one-to-one correspondence between substorm intensity and GIC magnitude.
To study the geomagnetic disturbance impact on the power systems of the Kola Peninsula, the Center of physical-technical problems of energetics of the North jointly with the Polar Geophysical Institute developed a system of GIC monitoring in "Kolenergo" company networks. A system of digital registration of GIC was developed, which provides a continuous measurement of DC of dead-grounded neutral of the power autotransformer at the power system substations of 110-330 kV class and the monitoring of the frequency spectrum of the industrial frequency voltage (50 Hz). Increases of geoinduced currents (GIC) in the power line, oriented south-north can be observed under the average and high levels of activity (Kp=4-9) in the evening and night hours. The obtained data can be used for modeling the coupling between geomagnetic disturbances and GIC in power lines.
The rapid changes dB/dt of the Earth’s magnetic field due to substorms can excite large geomagnetically-induced currents (GICs) that can have harmful effects on technological systems. This paper presents an analysis of the characteristics of dB/dt enhancements observed in Fennoscandia using data from the IMAGE magnetometer chain along a geomagnetic longitude of 110o. The abrupt geomagnetic field variations may be associated with the substorm onsets, isolated magnetic impulsive events (MIEs), and quasi-periodic series of MIEs, known as Ps6 pulsations (periods 5-15 min). For a detailed examination of the latitudinal structure of dB/dt enhancements and their association with the auroral oval boundaries we applied the technique of magnetic keograms. This simple technique helps to visualize and characterize the fine structure of substorm, namely the location in time and latitude of dB/dt enhancements. The location of the auroral oval boundaries has been estimated with the OVATION-prime model. Among the different types of impulsive disturbances investigated auroral substorm onset provides the largest GICs (few tens of A). Isolated nightside MIEs are also effective in the excitation of GICs (>10 A). Ps6 pulsations are effective in the excitation of GICs with magnitude about 20 A and even higher. Monochromatic Pc5 pulsations are capable to induce noticeable GICs, up to ~13 A. Large localized disturbances on short timescales are the actual drivers of GICs, and they may be imagined like geomagnetic “strokes” during magnetospheric “thunderstorms”.