13 April 2025 in Siberian Journal of Clinical and Experimental Medicine
Background. To organize screening of the population for pulmonary tuberculosis, services based on the use of artificial intelligence technologies (AI services) have been developed and registered.Aim: To evaluate diagnostic metrics and performance of the AI-service as medical decision support system within the framework of routine clinical practice at the scale of a municipal hospital.Material and Methods. The index test was conducted using the software “Automated analysis program for digital chest X-ray/ fluorography images according to TU 62.01.29-001-96876180-2019” produced by LLC “PhthisisBiomed”.Results. The index test of the AI service as a system for supporting medical decision-making showed high values of operational characteristics (sensitivity 96%, specificity 61%), significant savings in the time spent on forming conclusions, and high data transfer rate. The choice of the optimal separation point for screening is reasonably based on the metric of maximizing the predictive value of a negative result (sensitivity maximization). When comparing the diagnostic efficiency of AI-service solutions and physicians, it is shown that the area under the ROC curve of AI-service conclusions (0.91–0.93) is not inferior to that of qualified radiologists (0.78-0.91 according to the literature.Discussion. The use of AI service allows to significantly save the time required to analyze one X-ray image, which is especially important for rapid diagnostics within the framework of screening programs. The use of AI service with high diagnostic efficiency expands the capabilities of radiologists and indicates a transition to a new level of quality of medical care. High speed data transfer allows for better coordination between medical staff and enables faster decision-making for patients.Conclusions. Detection of pathological changes on radiographs of patients using AI-service has high diagnostic efficiency and can be used within the framework of population screening programs for lung diseases.
2 July 2024 in Digital Diagnostics
BACKGROUND: The volume of medical diagnostic studies continues to increase annually, intensifying the desire to implement advanced technologies in the field of medical diagnostics. One of the promising approaches that has attracted attention is the use of artificial intelligence in this area. A study was conducted on the automated analysis of chest radiographs using the AI service PhthisisBioMed at a city hospital specializing in the treatment of respiratory diseases. AIM: The study aimed to assess the diagnostic accuracy of the artificial intelligence service “PhthisisBioMed” for the detection of respiratory pathologies in the context of a city hospital that provides 24-hour specialized care in the field of pulmonology. MATERIALS AND METHODS: This study employed a prospective design, with the results of the artificial intelligence service available to the physician on request. This enabled the physician to review the results of the service if an alternative opinion was needed. The reference test was conducted by radiologists at Samara City Hospital No. 4, who described the examinations performed during the testing period. The index test was performed on the software “Program for Automated Analysis of Digital Chest Radiographs/Fluorograms according to TU 62.01.29-001-96876180-2019” produced by PhthisisBioMed LLC. The PhthisisBioMed software was employed to analyze digital fluorograms of the lungs in direct anterior projection. The software automatically identified the following radiological signs of pathologies: pleural effusion, pneumothorax, atelectasis, darkening, infiltration/consolidation, dissemination, cavity, calcification/calcified shadow, and cortical layer integrity violation. Fluorograms of patients over the age of 18 were included in the analysis. The study was conducted within the framework of research and development work No. 121051700033-3, entitled “Lung Damage of Infectious Etiology. Improvement of Methods of Detection, Diagnosis and Treatment” (14.05.2021). RESULTS: Following the pilot operation of the PhthisisBioMed artificial intelligence service and subsequent ROC analysis, the diagnostic accuracy metrics claimed by the manufacturer of the artificial intelligence medical device were confirmed. The service provided the probability of the presence of various pathologies. According to the highlighted labels, 63 patients (4.8%) were suspected of tuberculosis based on characteristic radiologic features. The conclusion was made independently by the radiologist, and the results were evaluated by the attending physician. The attending physician had the opportunity to compare the results and discuss them with the radiologist if differences were found. The results of the survey of pulmonologists who participated in the study indicated that the conclusion of the artificial intelligence service was received automatically within 15 seconds, while the conclusion of the physician was received within 30 minutes or more. CONCLUSIONS: The results of the study indicate that the implementation of the PhthisisBioMed software is expedient both in the outpatient department of the hospital in terms of assessing the annual fluorographic examination of the population, and in the pulmonology service of the city, inpatient and admission department of the hospital.
26 February 2026 in Digital Diagnostics
ПВПетряйкин Алексей Владимирович
Петряйкин Алексей Владимирович
+2
BACKGROUND: The regulated quality control procedure for radiography involves the analysis of test objects without simulating anatomical features. However, subsequent assessment of radiologists’ performance or artificial intelligence-based decision support systems requires anonymized data samples from real patients annotated by multiple specialists. Collecting such datasets is a labor-intensive and time-consuming process, especially when we need a sample containing actual pathologies. Therefore, it is advisable to use anthropomorphic test objects (phantoms) which simulate pathological findings, so that the X-ray image will be as close as possible to the analyzed images of patients. AIM: To develop and test an anthropomorphic aluminum phantom for digital radiography. METHODS: A digital radiograph of the chest of a healthy person was used as a reference standard during phantom design. A sample of the designed phantom was made using layer-by-layer milling of an aluminum blank. Validation was carried out by comparing phantom images and the reference image. In addition, the effect of the phantom sample on the spatial resolution and contrast sensitivity was assessed for different acquisition modes of the X-ray unit. The applicability of the phantom for simulating focal lung lesions was studied, with the results evaluated by experts. RESULTS: The phantom was found to reproduce the reference image with a high fidelity and allows simulation of pathological changes in chest X-rays by placing flexible pads in the required positions. The ratios of attenuation coefficients for different anatomical areas were identified during X-ray imaging of the phantom and three patients. CONCLUSION: This work presents a method for developing a high-fidelity anthropomorphic phantom made of D16T aluminum alloy, designed for calibrating X-ray systems and testing radiologists. The phantom imitates the anatomical structures of the chest organs and pathological changes, such as focal lesions. The main advantages of this solution include reduced production costs, compact design, and high accuracy of reproduction of radiographic characteristics.