Mahnaz Sheikhi

Mahnaz Sheikhi

Auto-generated profile, based on publicly available information

Mahnaz Sheikhi

Department of Oral and Maxillofacial Radiology, Torabinejad Dental Research Center, School of Dentistry, Isfahan University of Medical Sciences, Isfahan Po. Code: 8174673461, Iran

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 September 2022 in Scanning
Verified
Journal Article
Open access
PDF file
AKAbbasali Khademi
Abbasali Khademi
MSMasoud Saatchi
Masoud Saatchi
MSMahnaz Sheikhi
Mahnaz Sheikhi
MSMohammad Mehdi Soltani
Mohammad Mehdi Soltani
SMSamane Moradi
Samane Moradi
Objectives. The percentage of failure of endodontically treated maxillary molars is relatively high; one main reason is that the second mesiobuccal canal (MB2) is missing. Some techniques have been proposed for detection of the MB2. This study was aimed at assessing the diagnostic accuracy and agreement of the dental microscope and cone-beam computed tomography (CBCT) in comparison with microcomputed tomography (micro-CT) for detection of the MB2 of maxillary first molars in vitro. Materials and Methods. This in vitro, experimental study evaluated 71 permanent maxillary first molars that were stored in 100% humidity at room temperature. The teeth were mounted in 9 silicone dental arches to the level of their cementoenamel junction (8 teeth in each arch). The blocks underwent CBCT in a XG3D scanner. Access cavity was then prepared, and the teeth were inspected by a surgical microscope for negotiation of the MB2. Also, micro-CT images were obtained from the teeth to serve as the gold standard. CBCT and micro-CT images were observed by two examiners twice with a 2-week interval. Results. The frequency of the MB2 detected by dental microscope was significantly lower than micro-CT ( ) and CBCT ( ); no significant difference existed between micro-CT and CBCT in this respect. The sensitivity, specificity, positive predictive value, and negative predictive value of CBCT for detection of MB2 were 92.6%, 100%, 100%, and 81%, respectively. Conclusion. CBCT is superior to the dental microscope for detection of the MB2 of maxillary first molars and can be used for this purpose in the clinical setting with adequate accuracy.

12 April 2019 in The Egyptian Journal of Otolaryngology
Verified
Journal Article
Open access
PDF file
MKMitra Karbasi Kheir
Mitra Karbasi Kheir
MSMahnaz Sheikhi
Mahnaz Sheikhi
Ectopic tooth eruption in maxillary sinus is rare. Ectopic eruption in maxillary sinus usually causes sinonasal or ophthalmic symptoms, but asymptomatic cases are less reported. A 26-year-old man was referred to take a presurgical implant cone beam computed tomography of his anterior part of maxilla. The cone beam computed tomography projections showed an accidental finding of ectopic maxillary third molar in the posterior portion of left maxillary sinus. The patient did not report any history of swelling or pain. Although the patient was asymptomatic, the impacted tooth was removed because of the tendency of untreated impacted teeth to form cyst or tumor. The tooth was removed through Caldwell-Luc procedure.

22 December 2020 in Brazilian Dental Science
Verified
Journal Article
Open access
PDF file
MSMahnaz Sheikhi
Mahnaz Sheikhi
MKMehdi Karami
Mehdi Karami
SASomayeh Abbasi
Somayeh Abbasi
AMAmirhossein Moaddabi
Amirhossein Moaddabi
PSParisa Soltani
Parisa Soltani
Objective: To evaluate the relationship between bone density measured by computed tomography (CT) and cone beam computed tomography (CBCT) (Sirona’s Galileos scanner) with primary stability of dental implants. Material and methods: 20 fresh bovine femoral heads were prepared by removal of soft tissue, sectioning of the bone, and placement of markers for location and angulation of implants. Bone density of peri-implant areas was determined preoperatively by CT and CBCT scanning of the prepared bone samples represented by Hounsfield units (HUs) and gray values (GVs), respectively. Then, 60 implants in three sizes (diameter = 4 mm, length = 8, 10, and 12 mm) were inserted into the bones and maximum insertion torque (IT) was recorded. Osstell device was also used for determining the implant stability quotient (ISQ) for each implant. Statistical analysis was performed on the data (alpha = 0.05). Results: Mean ± SD values of GV, HU, and ISQ were 1592.75 ± 231.82, 675.26 ± 115.38 and 61.90 ± 10.14, respectively. Moreover, the most frequent IT limit was 30-35 Ncm (41.4%). Significant relationships were observed between HU and IT, GV and IT, HU and ISQ, GV and ISQ, and IT and ISQ in all implant sizes. Moreover, GV and HU also significantly correlated to each other. Conclusion: Bone density values in CBCT and CT scans are positively associated to primary stability of dental implants. Therefore, GVs obtained from Galileos CBCT scanner can be used for preoperative selection of edentulous sites which allow for better implant stability or locations which require further procedures for enhancing the success rate of dental implants. KEYWORDSComputed tomography; Cone beam computed tomography; Dental implant.