Yu Sun

Yu Sun

Auto-generated profile, based on publicly available information

Yu Sun

Department of Biomedical Engineering, The Hong Kong Polytechnic University, Hong Kong, China

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 August 2021 in ACS Applied Materials & Interfaces
Verified
Journal Article
Closed access
YSYu Sun
Yu Sun
JCJing Cao
Jing Cao
XWXue Wang
Xue Wang
CZCong Zhang
Cong Zhang
JLJiali Luo
Jiali Luo
PHPin-tong HUANG
Pin-tong HUANG

31 August 2022 in ACS Applied Materials & Interfaces
Verified
Journal Article
Closed access
JLJiali Luo
Jiali Luo
JCJing Cao
Jing Cao
GMGuangrong Ma
Guangrong Ma
XWXue Wang
Xue Wang
YSYu Sun
Yu Sun
PHPin-tong HUANG
Pin-tong HUANG

13 November 2024 in Computer Methods and Programs in Biomedicine
Verified
Journal Article
Closed access
HKHong-Yu Kang
Hong-Yu Kang
WZWei ZHANG
Wei ZHANG
SLShuai Li
Shuai Li
XWXinyi Wang
Xinyi Wang
YSYu Sun
Yu Sun
YZY.P. Zheng
Y.P. Zheng

29 September 2025 in IEEE Journal of Biomedical and Health Informatics
Verified
Journal Article
Open access
XWXinyi Wang
Xinyi Wang
SLSai Kit Lam
Sai Kit Lam
HKHongyu Kang
Hongyu Kang
YSYu Sun
Yu Sun
CHChao Hou
Chao Hou
YZY.P. Zheng
Y.P. Zheng
Transcranial sonography (TCS) provides a non-invasive means of assessing movement disorders such as Parkinson's disease (PD). However, current TCS-based evaluations rely heavily on manual operation by experienced physicians, making the process time-consuming and physician-dependent. For the first time, we aimed to develop a hybrid pipeline for real-time video object segmentation (VOS) and automatic optimal frame selection. Eighty-three standardized TCS real-time data comprising 1,992 midbrain frames from Beijing Tiantan Hospital were collected. We adopted three state-of-the-art VOS models (STCN, RDE-VOS, and XMEM) and incorporated anatomical priors to guide optimal frame selection. Specifically, we leveraged the anatomical trend of midbrain morphology to estimate the midbrain radius at the optimal frame and selected the frame where the VOS-segmented midbrain best matched this estimate. The XMEM-based pipeline achieved high segmentation performance (Jaccard: 0.85, Boundary Accuracy: 0.95, Dice: 0.92) and optimal frame selection (Distance: 4.87; Jaccard: 0.92), with efficiency (51.05 FPS, 0.56 s/patient, 661.55 MB). Subgroup analyses confirmed robustness across image quality and PD conditions. Assessment of a junior physician's selection suggests potential to reduce the expertise gap in optimal frame selection. The proposed hybrid pipeline offers an automated tool for midbrain assessment using TCS, which may help reduce physicians' workload and minimize subjectivity, particularly supporting junior physicians in mitigating the expertise-demanding nature of TCS. This approach may serve as a foundation for more promising TCS-based assessments in the future, contributing to broader adoption of non-invasive ultrasound techniques in PD evaluation.