Mario Lentini

Mario Lentini

Auto-generated profile, based on publicly available information

Mario Lentini

European Synchrotron Radiation Facility, 71 Avenue des Martyrs, 38000 Grenoble, France

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
27 June 2018 in Journal of Synchrotron Radiation
Verified
Journal Article
Open access
PDF file
AMAndrew Aloysius Mccarthy
Andrew Aloysius Mccarthy
RBRay Barrett
Ray Barrett
ABAntonia Beteva
Antonia Beteva
HCHugo Caserotto
Hugo Caserotto
FDFabien Dobias
Fabien Dobias
CMChristoph Mueller-Dieckmann
Christoph Mueller-Dieckmann
ID30B is an undulator-based high-intensity, energy-tuneable (6.0–20 keV) and variable-focus (20–200 µm in diameter) macromolecular crystallography (MX) beamline at the ESRF. It was the last of the ESRF Structural Biology Group's beamlines to be constructed and commissioned as part of the ESRF's Phase I Upgrade Program and has been in user operation since June 2015. Both a modified microdiffractometer (MD2S) incorporating an in situ plate screening capability and a new flexible sample changer (the FlexHCD) were specifically developed for ID30B. Here, the authors provide the current beamline characteristics and detail how different types of MX experiments can be performed on ID30B (http://www.esrf.eu/id30b).

29 April 2020 in Journal of Synchrotron Radiation
Verified
Journal Article
Open access
PDF file
DSDavid von Stetten
David von Stetten
PCphilippe carpentier
philippe carpentier
DFDavid Flot
David Flot
ABAntonia Beteva
Antonia Beteva
HCHugo Caserotto
Hugo Caserotto
CMChristoph Mueller-Dieckmann
Christoph Mueller-Dieckmann
ID30A-3 (or MASSIF-3) is a mini-focus (beam size 18 µm × 14 µm) highly intense (2.0 × 1013 photons s−1), fixed-energy (12.81 keV) beamline for macromolecular crystallography (MX) experiments at the European Synchrotron Radiation Facility (ESRF). MASSIF-3 is one of two fixed-energy beamlines sited on the first branch of the canted undulator setup on the ESRF ID30 port and is equipped with a MD2 micro-diffractometer, a Flex HCD sample changer, and an Eiger X 4M fast hybrid photon-counting detector. MASSIF-3 is recommended for collecting diffraction data from single small crystals (≤15 µm in one dimension) or for experiments using serial methods. The end-station has been in full user operation since December 2014, and here its current characteristics and capabilities are described.