Xuan Zhang

Xuan Zhang

Auto-generated profile, based on publicly available information

Xuan Zhang

Beijing University of Posts and Telecommunications, Beijing, China

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
4 August 2024
Verified
Conference Paper
Open access
KLKefei Liu
Kefei Liu
ZJZhuo Jiang
Zhuo Jiang
JZJiao Zhang
Jiao Zhang
SGShixian Guo
Shixian Guo
XZXuan Zhang
Xuan Zhang
THTao Huang
Tao Huang
RoCE services are sensitive to network failures and performance bottlenecks, which become more common as the RoCE network scales. In addition, some non-network problems behave like network problems and can waste troubleshooting time. However, existing mechanisms cannot quickly detect and locate network problems or determine whether the service problem is network-related. In this paper, we propose R-Pingmesh, the first service-aware RoCE network monitoring and diagnostic system based on end-to-end probing. R-Pingmesh can accurately measure network RTT and end-host processing delay based on commodity RDMA NICs (RNICs), distinguish between RNIC and in-network packet drops, and judge whether a problem is network-related and assess its impact on services. We have deployed R-Pingmesh on tens of thousands of RNICs for over 6 months. One-month evaluation results show that 85% of the problems located by R-Pingmesh are accurate, where all 157 switch network problems are accurate. R-Pingmesh efficiently detects and locates 14 types of problems during deployment, and we share our experience in dealing with them.

3 August 2024
Verified
Conference Paper
Open access
KLKefei Liu
Kefei Liu
JZJiao Zhang
Jiao Zhang
ZJZhuo Jiang
Zhuo Jiang
XZXuan Zhang
Xuan Zhang
SGShixian Guo
Shixian Guo
THTao Huang
Tao Huang
RoCE services are sensitive to failures and bottlenecks, which become more common as the RoCE network scales. To effectively detect and locate these problems independent of service traffic, RoCE networks require a monitoring and diagnostic system based on active probing. However, existing active probing schemes typically rely on a controller to design the probing plan for each server, which is difficult to deploy and has high synchronization overhead in multi-tenant clusters. Fortunately, rail-optimized clusters have become more common in recent years to improve network performance. In these clusters, the controller is unnecessary. In this paper, we propose Hostmesh, the first network monitoring and diagnostic system for rail-optimized RoCE clusters based solely on full-mesh probing between RDMA NICs on the same host. Hostmesh uses the feature of rail-optimized networks and does not rely on a controller to generate pinglists. We deployed Hostmesh for over three months on a multi-tenant rail-optimized RoCE cluster with hundreds of servers. During the deployment, Hostmesh effectively detected and located 8 types of problems caused by hardware failures, misconfigurations, network congestion, and intra-host bottlenecks. And we share our experience in dealing with them.