Benedikt Hauer

Benedikt Hauer

Auto-generated profile, based on publicly available information

Benedikt Hauer

Fraunhofer Institute for Physical Measurement Techniques IPM Georges‐Köhler‐Allee 301 79110 Freiburg Germany

Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 July 2025 in Advanced Materials
Verified
Journal Article
Open access
RYRenukka Yaadav
Renukka Yaadav
KTKateryna Trofymchuk
Kateryna Trofymchuk
MDMihir Dass
Mihir Dass
VBVivien Behrendt
Vivien Behrendt
BHBenedikt Hauer
Benedikt Hauer
PTPhilip Tinnefeld
Philip Tinnefeld
Creating increasingly sensitive and cost‐effective nucleic acid detection methods is critical for enhancing point‐of‐care (POC) applications. This requires highly specific capture of biomarkers and efficient transduction of capture events. However, the signal from biomarkers present at extremely low amounts often falls below the detection limit of typical fluorescence‐based methods, necessitating molecular amplification. Here, we present single‐molecule detection of a non‐amplified, 151‐nucleotide sequence specific to antibiotics‐resistant Klebsiella pneumoniae down to attomolar concentrations, using Trident NanoAntennas with Cleared HOtSpots (NACHOS). This NACHOS‐diagnostics assay leverages a compact microscope with a large field‐of‐view, including microfluidic flow to enhance capturing efficiency. Fluorescence enhancement is provided by NanoAntennas, arranged using a combination of nanosphere lithography and site‐specific DNA origami placement. This method can detect 200 ± 50 out of 600 molecules in a 100 µL sample volume within an hour. This represents a typical number of pathogens in clinical samples commonly detected by Polymerase Chain Reaction. We achieve similar sensitivity in untreated human plasma, enhancing the practical applicability of the system. This platform can be adapted to detect shorter nucleic acid fragments that are not compatible with traditional amplification‐based technologies. This provides a robust and scalable solution for sensitive nucleic acid detection in diverse clinical settings.

14 May 2025 in Applied Spectroscopy
Verified
Journal Article
Open access
FMFriederike Münch
Friederike Münch
BHBenedikt Hauer
Benedikt Hauer
IBIngo Breunig
Ingo Breunig
DCDaniel Carl
Daniel Carl
Polymer films with a thickness in the two-digit micrometer range are coated with nanometer-thin oxide layers in roll-to-roll coating systems. The coating improves the properties of the film, such as gas or water permeation. Maintaining a sufficiently large coating thickness is crucial to ensure its barrier function; thus, inline quality control of the thickness is indispensable. For this purpose, we have developed a sensing principle that addresses specific absorption bands of the coating via a reflection measurement in the infrared spectral range. However, for thin and weakly absorbing polymer substrates, light is reflected not only by the coating and the surface of the polymer. Partly it is also transmitted and reflected by the backside of the film, leading to interference effects that significantly affect the measurement signal. As industrial films vary in thickness by several percent and their exact values are unknown, determining the thickness of an oxide coating is hindered. In this paper, we demonstrate an approach for measuring coating thickness on such varying polymer films by averaging the interferences obtained at multiple angles of incidence. Calculations and measurements on industrial film samples indicate the effectiveness of our approach. It produces results with ± 2 nm precision and ± 5 nm accuracy for a thickness in the range of 5–100 nm. Furthermore, we discuss a possible implementation of this approach in an inline measurement system by fulfilling its requirements, for example, versatility and compactness.