Javier Bujalance-Fernández

Javier Bujalance-Fernández

Auto-generated profile, based on publicly available information

Javier Bujalance-Fernández

Department of Analytical Chemistry Physical Chemistry and Chemical Engineering Universidad de Alcala Madrid Spain

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 December 2023 in Advanced Functional Materials
Verified
Journal Article
Open access
CCCarmen Cuntín‐Abal
Carmen Cuntín‐Abal
JBJavier Bujalance‐Fernández
Javier Bujalance‐Fernández
KYKaisong Yuan
Kaisong Yuan
AAAna Arribi
Ana Arribi
Beatriz Jurado-SánchezBeatriz Jurado-Sánchez
Beatriz Jurado-Sánchez
Alberto EscarpaAlberto Escarpa
Alberto Escarpa
Herein, T4‐bacteriophage‐funcionalizated magnetic Janus micromotors are used for the first time for highly selective Escherichia coli (E. coli) recognition and detection. The micromotors propel at speeds of up to 40 µm s−1 in complex biological samples for on‐the‐fly capture of E. coli “strain B”‐thiolated T4 bacteriophage complex. Detection is achieved by a simplified colorimetric readout in connection with gold nanoparticles. The detection limit meets the cut‐off for the fast diagnosis of urinary tract infections. The bacteriophage‐engineered micromotors are tested on bacteria isolated from urine samples and in serum isolated from negative blood cultures from hospital patients with excellent selectivity and reliability. The new strategy described here holds considerable promise for the multiplexed detection of a myriad of bacteria strains using tailored bacteriophages. Technically, this is the first microplate‐reader integrated micromotor approach, crossing another bridge from the research lab to the practical use of micromotors. Specifically, these results represent a qualitative step forward in the use of micromotor technology with sophisticated functionalization for fast bacteria screening in clinical settings.

3 August 2023 in Chemical Communications
Verified
Journal Article
Open access
PDF file
JBJavier Bujalance-Fernández
Javier Bujalance-Fernández
Beatriz Jurado-SánchezBeatriz Jurado-Sánchez
Beatriz Jurado-Sánchez
Alberto EscarpaAlberto Escarpa
Alberto Escarpa
Metal organic frameworks meet self-propelled micromotors for on-the move applications to solve complex challenges.

24 June 2024 in Analytical Chemistry
Verified
Journal Article
Open access
JBJavier Bujalance-Fernández
Javier Bujalance-Fernández
Beatriz Jurado-SánchezBeatriz Jurado-Sánchez
Beatriz Jurado-Sánchez
Alberto EscarpaAlberto Escarpa
Alberto Escarpa
The analysis and detection of snake venom toxins are a matter of great importance in clinical diagnosis for fast treatment and the discovery of new pharmaceutical products. Current detection methods have high associated costs and require the use of sophisticated bioreceptors, which in some cases are difficult to obtain. Herein, we report the synthesis of template-based molecularly imprinted micromotors for dynamic detection of α-bungarotoxin as a model toxin present in the venom of many-banded krait (Bungarus multicinctus). The specific recognition sites are built-in in the micromotors by incubation of the membrane template with the target toxin, followed by a controlled electrodeposition of a poly(3,4-ethylenedioxythiophene)/poly(sodium 4-styrenesulfonate) polymeric layer, a magnetic Ni layer to promote magnetic guidance and facilitate washing steps, and a Pt layer for autonomous propulsion in the presence of hydrogen peroxide. The enhanced fluid mixing and autonomous propulsion increase the likelihood of interactions with the target analyte as compared with static counterparts, retaining the tetramethylrhodamine-labeled α-bungarotoxin on the micromotor surface with extremely fast dynamic sensor response (after just 20 s navigation) in only 3 μL of water, urine, or serum samples. The sensitivity achieved meets the clinically relevant concentration postsnakebite (from 0.1 to 100 μg/mL), illustrating the feasibility of the approach for practical applications. The selectivity of the protocol is very high, as illustrated by the absence of fluorescence in the micromotor surface in the presence of α-cobratoxin as a representative toxin with a size and structure similar to those of α-bungarotoxin. Recoveries higher than 95% are obtained in the analysis of urine- and serum-fortified samples. The new strategy holds considerable promise for fast, inexpensive, and even onsite detection of several toxins using multiple molecularly imprinted micromotors with tailored recognition abilities.

3 June 2025 in Small Methods
Verified
Journal Article
Open access
JFJavier Bujalance Fernández
Javier Bujalance Fernández
VAVíctor de la Asunción‐Nadal
Víctor de la Asunción‐Nadal
Beatriz Jurado-SánchezBeatriz Jurado-Sánchez
Beatriz Jurado-Sánchez
Alberto EscarpaAlberto Escarpa
Alberto Escarpa
Herein, the synthesis of macroporous zeolitic imidazole framework (ZIF)‐based magnetic micromotors (MMs) for the dual encapsulation of 5‐fluorouracil (5‐FU) and doxorubicin (DOX), with pH‐triggered release is described. The MMs are synthesized in methanolic solutions, using superparamagnetic iron oxide nanoparticles (Fe₃O₄) as seeding agents and magnetic engines. The macroporous structure facilitates the loading of high doses of 5‐FU, while DOX is docked on the surface of the MMs. This results in release rates of 72.8 µg mg MMs⁻¹ of 5‐FU and 3 µg mg MMs⁻¹ of DOX. The magnetic motion of the MMs enables targeted delivery to predefined locations, allowing interaction with cancer cells in the culture medium. Under acidic conditions, DOX becomes protonated and is released from the surface of the micromotors, demonstrating rapid‐release kinetics. Simultaneously, the ZIF‐8 structure degrades under these conditions, enabling the sustained release of 5‐FU for continuous treatment. This dual‐delivery, pH‐induced mechanism is demonstrated in vitro using Caco‐2 cells as a relevant biological model, revealing a decrease in viability and diffusion of the drugs released into the cells. This is the first magnetic metal–organic framework (MOF)‐based MM that is pH‐sensitive and capable of sequentially releasing two drugs.

20 March 2023 in Nanoscale
Verified
Journal Article
Open access
PDF file
VAVíctor de la Asunción-Nadal
Víctor de la Asunción-Nadal
JBJavier Bujalance-Fernández
Javier Bujalance-Fernández
Beatriz Jurado-SánchezBeatriz Jurado-Sánchez
Beatriz Jurado-Sánchez
Alberto EscarpaAlberto Escarpa
Alberto Escarpa
A fuel-free strategy for the eradication of Escherichia coli and Staphylococcus aureus biofilms using WS 2 and MoS 2 photophoretic microflakes is described.

12 October 2024 in Nanoscale
Verified
Journal Article
Open access
PDF file
JBJ. Bujalance-Fernández
J. Bujalance-Fernández
ECE. Carro
E. Carro
Beatriz Jurado-SánchezBeatriz Jurado-Sánchez
Beatriz Jurado-Sánchez
Alberto EscarpaAlberto Escarpa
Alberto Escarpa
Alzheimer's disease (AD) is the major cause of irreversible dementia in the elderly population worldwide and one of the major causes of the decrease in the quality of life. Efficient diagnosis and monitoring would allow a fast treatment to delay the appearance of symptoms. Herein, zeolitic imidazole framework (ZIF-8)@Au@catalase micromotors are described for motion-based sensing of copper as a marker of AD. The synthesis design was based on enzyme covalent immobilization instead of encapsulation to maximize the contact with the sample at the microscale for the potential use of extremely low AD-diagnosed sample volumes. The micromotors are prepared by asymmetric modification of ZIF-8 with a gold layer for functionalization of catalase as a compatible biocatalyst. The micromotors can propel at speeds of up to 287 ± 41 μm s−1 in cerebrospinal fluid (CSF) samples of healthy volunteers. Yet, in the presence of copper, catalase poisoning results in a decrease in the speed that can be monitored for motion-based sensing detection, as illustrated in the analysis of CSF samples from AD patients from mild to severe stages (Braak III to Braak VI). The copper-mediated modulation of catalase activity proposed here as an indicator of progression states in AD disease possesses distinct advantages such as ultrafast analysis (less than 1 min) and requiring only 1 μL of sample, holding considerable promise as a supporting prescreening tool for fast diagnosis of AD and other neurodegenerative diseases.