Daniel Magee

Daniel Magee

Auto-generated profile, based on publicly available information

Daniel Magee

Department of Urology Royal Perth Hospital Perth WA Australia

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 February 2024 in Journal of Endourology
Verified
Journal Article
Closed access
BMBegoña Ballesta Martinez
Begoña Ballesta Martinez
DMDaniel Savio Magee
Daniel Savio Magee
ATArman Tsaturyan
Arman Tsaturyan
VTVasileios Tatanis
Vasileios Tatanis
APAngelis Peteinaris
Angelis Peteinaris
Panagiotis KallidonisPanagiotis Kallidonis
Panagiotis Kallidonis
Objective: The aim of the study was to characterize artificial stones which are used for research in endourology from the perspective of radiological properties and hardness in terms of stone fragmentation, and to compare them to real stones from those assessments. Materials and Methods: We built artificial stones from BegoStone Plus powder (BEGO Lincoln, RI, USA) with powder(grams): water(ml) ratios from 15:03 to 15:12. The CT Gemstone Spectral Imaging Software (GE Medical Systems, LLC. Waukesha, WI, U.S.A) was used to evaluate the radiological density in Hounsfield Units (HU) and spectral properties. Stone fragmentation was assessed with an in vitro experimental setting. Artificial stones were compared to real urinary calculi from those perspectives. Results: Regarding radiological density in terms of HU, 15:03 artificial calculi showed similar results compared to real stones composed of Calcium Oxalate and Calcium Phosphate. Spectral properties wise, 15:03 and 15:04 artificial stones showed similar results than calcium pyrophosphate stones. Stone fragmentation wise, 15:11 artificial stones showed similar results than real stones composed of uric acid. 15:03 artificial calculi showed similar results than apatite and cystine stones. Conclusions: Artificial stones are very useful for research in endourology. Stones with a gr of powder: ml water ratio of 15:03 proved to mimic hard real stones in terms of HU, atomic number and stone fragmentation in our study and could be used as artificial hard stones. 15:11 stones showed similar stone fragmentation than uric acid stones. Our study might suggest that standard Bego stones are a very useful material to investigate different areas in endourology but not radiological properties because radiological homogeneity is not ensured unless using more sophisticated mixing methods.

1 March 2025 in Research and Reports in Urology
Verified
Journal Article
Open access
PDF file
DMDaniel Magee
Daniel Magee
NTNinan Tharakan
Ninan Tharakan
YYYuigi Yuiminaga
Yuigi Yuiminaga
Objective: Bladder cancer is the 10th most common cancer worldwide. The investigation and surveillance commonly involve a combination of upper tract imaging along with visual assessment of the bladder via cystoscopy. This study determined the validity of using Cxbladder® Triage (CxbT) and Cxbladder® Monitor (CxbM) as a suitable adjunct in ruling out urothelial carcinoma (UC) when investigating haematuria or monitoring for recurrence. Materials and methods: A single centre prospective study where the patients have been referred for investigation of UC or those on routine surveillance of known UC. All patients were counselled with consent obtained prior to midstream urine collection pre-cystoscopy in line with local protocol for urine-analysis to screen for infection with the residual specimen collected for the CxbT or CxbM test. De-identified patient demographic data along with smoking status, risk of environmental exposures, family history, type of hematuria or last date of last recurrence were collected, and the planned cystoscopy would then proceed. The data pertaining to exposure to smoking and type of haematuria are the symptoms and risk factors that are taken into account with CxbT or CxbM to calculate a score, which can then be correlated with the outcome at the end with cystoscopic and imaging investigations. Results: A combined 236 patients were recruited (CxbT = 134, CxbM = 102) with results showing excellent negative predictive value of 96.43% and 95.16%, respectively. A key result showed that CxbT in combination with upper tract imaging done as routine was able to rule out UC completely in low-risk patients. Conclusion: We have validated the use of Cxbladder as an adjunct in the investigation and surveillance of UC. It is a non-invasive, accurate and reproducible test that can aid in ruling out UC, specifically for low-risk patients.

1 September 2024 in Research and Reports in Urology
Verified
Journal Article
Open access
PDF file
DMDaniel Magee
Daniel Magee
FJFeroza Jeewa
Feroza Jeewa
MCMatthew Vinh-Hoan Dinh Chau
Matthew Vinh-Hoan Dinh Chau
PLPamphila Lovelle Loh
Pamphila Lovelle Loh
BMBegona Ballesta Martinez
Begona Ballesta Martinez
YYYuigi Yuiminaga
Yuigi Yuiminaga
Objective: To assess the capability of determining the mixed chemical composition of urinary stones using spectral imaging properties of Dual Energy Computed Tomography (DECT) Gemstone Spectral Imaging (GSI) software. Material and Methods: Twenty-six single and 24 mixed composition ex vivo urinary stones with known chemical composition determined by Fourier-transform infrared spectroscopy (FTIR) prior to this project were scanned with DECT imaging and GSI in vitro. The major components of the stones included Uric Acid (UA), Calcium Oxalate (CaOx), Calcium Phosphate (CaP), Magnesium Ammonium Phosphate (MAP), and Cystine (Cys). A histogram to display the distribution of the effective atomic number (Z-eff) of each pixel of the tested area, spectral curve (40– 140 keV, with 10 keV interval) and Hounsfield Units (HU) of each stone scanned was provided with analysis of monochromatic images at 140 keV in the axial plane. Results: The overall pooled sensitivity, specificity, and accuracy of DECT for identifying major stone composition were 0.802, 0.831, and 0.807, respectively, with a 95% confidence interval. Accuracy was 100% for identifying UA and Cys stones. Conclusion: DECT is a superior imaging modality when compared to low dose computed tomography kidney ureter bladder scans. It allows for improved characterization of major components of urinary stones, in an accurate, non-invasive approach to pre-treatment. This can translate to urologists having greater confidence in determining patient suitability for medical or surgical management of their renal stones, in clinical practice.

15 April 2024 in Irish Journal of Medical Science (1971 -)
Verified
Journal Article
Closed access
PDF file
DMDaniel Magee
Daniel Magee
MBMitchell Barns
Mitchell Barns
MCMatthew Chau
Matthew Chau
LBLaura Bailey
Laura Bailey
YYYuigi Yuminaga
Yuigi Yuminaga