Osman Erdoğan

Osman Erdoğan

Auto-generated profile, based on publicly available information

Osman Erdoğan

Şanlıurfa Training and Research Hospital

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
2 August 2016 in Brazilian Journal of Otorhinolaryngology
Verified
Journal Article
Open access
OIOnur Ismi
Onur Ismi
OEOsman Erdogan
Osman Erdogan
MYMesut Yesilova
Mesut Yesilova
COCengiz Ozcan
Cengiz Ozcan
DODidem Ovla
Didem Ovla
KGKemal Gorur
Kemal Gorur
Otosclerosis (OS) is the primary disease of the human temporal bone characterized by conductive hearing loss and tinnitus. The exact pathogenesis of tinnitus in otosclerosis patients is not known and factors affecting the tinnitus outcome in otosclerosis patients are still controversial. To find the effect of stapedotomy on tinnitus for otosclerosis patients. Fifty-six otosclerosis patients with preoperative tinnitus were enrolled to the study. Pure tone average Air-Bone Gap values, preoperative tinnitus pitch, Air-Bone Gap closure at tinnitus frequencies were evaluated for their effect on the postoperative outcome. Low pitch tinnitus had more favorable outcome compared to high pitch tinnitus (p=0.002). Postoperative average pure tone thresholds Air-Bone Gap values were not related to the postoperative tinnitus (p=0.213). There was no statistically significant difference between postoperative Air-Bone Gap closure at tinnitus frequency and improvement of high pitch tinnitus (p=0.427). There was a statistically significant difference between Air-Bone Gap improvement in tinnitus frequency and low pitch tinnitus recovery (p=0.026). Low pitch tinnitus is more likely to be resolved after stapedotomy for patients with otosclerosis. High pitch tinnitus may not resolve even after closure of the Air-Bone Gap at tinnitus frequencies.

30 October 2020 in International Journal Of Clinical Practice
Verified
Journal Article
Closed access
PDF file
AYAhmet Yukkaldıran
Ahmet Yukkaldıran
OEOsman Erdoğan
Osman Erdoğan
MKMehmet Erkan Kaplama
Mehmet Erkan Kaplama

1 September 2019 in International Journal of Pediatric Otorhinolaryngology
Verified
Journal Article
Closed access
OBORHAN BEGER
ORHAN BEGER
OEOsman Erdoğan
Osman Erdoğan
EKEngin Kara
Engin Kara
YVYusuf Vayisoğlu
Yusuf Vayisoğlu
KGKemal Görür
Kemal Görür
DTDerya Ümit Talas
Derya Ümit Talas

1 November 2017 in Journal of Craniofacial Surgery
Verified
Journal Article
Closed access
OEOsman Erdoğan
Osman Erdoğan
OIOnur Ismi
Onur Ismi
MTMesut Sabri Tezer
Mesut Sabri Tezer
Paranasal sinus osteomas are among the rare causes of headache and they are most commonly seen in the frontal and ethmoid sinuses. In this report, we presented the first case of pneumatized nasal septum osteoma causing headache, successfully treated with endoscopic transnasal approach.

3 September 2019 in The Journal of International Advanced Otology
Verified
Journal Article
Open access
OEOsman Erdoğan
Osman Erdoğan
TKTuran Koç
Turan Koç
GKGülden Kayan
Gülden Kayan
VHVural Hamzaoğlu
Vural Hamzaoğlu
EKEngin Kara
Engin Kara
OBORHAN BEGER
ORHAN BEGER
OBJECTIVES: This study aimed to compare the right and left sides of the carotid foramen (CF) to determine its precise location according to certain anatomical landmarks. MATERIALS and METHODS: Twenty human dry skulls were included in the study. A digital caliper and a digital image analysis software were used to obtain direct anatomical numerical values. Then, the same parameters on dry skulls were assessed with computed tomography (CT). RESULTS: CF was found to be round shaped (62.5%), oval shaped (32.5%), and tear-drop shaped (5%). In all cases, the position of CF was seen as just postero-laterally of the foramen lacerum. According to the jugular foramen, CF was seen to be anterior in 85% and antero-medial in 15% of the cases. Regarding the morphometric values of the surface area, the length and width of CF were observed to be 37.86±11.24 mm2, 8.02±1.09 mm, and 6.86±0.90 mm at direct anatomical measurements and 39.69±10.07 mm2, 7.89±1.14 mm, and 6.41±0.90 mm at CT, respectively. The angles between the supramastoid crest-CF-zygoma root and the supramastoid crest-CF-mastoid process were determined as 37.11±6.87º and 42.22±6.40º at direct anatomical measurements and 36.59±4.94º and 43.71±4.55º at CT, respectively. CONCLUSION: A significant difference in sides was not observed in relation with the numerical data of CF obtained from CT or from direct anatomical measurements of dry skulls. Moreover, a significant difference was not found between radiological and direct anatomical measurements. Therefore, precise radiological assessment of this region by an experienced neuroradiologist may be assumed as a fundamental need for successful surgeries of the skull base, in addition to thorough anatomical knowledge of neurootologists and neurosurgeons. Cite this article as: Özalp H, Beger O, Erdoğan O, Koç T, Kayan G, Hamzaoğlu V, et al. Morphometric Assessment of the Carotid Foramen for Lateral Surgical Approach. J Int Adv Otol 2019; 15(2): 222-8.

1 October 2019 in Journal of Craniofacial Surgery
Verified
Journal Article
Closed access
OBOrhan Beger
Orhan Beger
OEOsman Erdoğan
Osman Erdoğan
ZÇZeynep Çetin
Zeynep Çetin
EKEngin Kara
Engin Kara
YVYusuf Vayisoğlu
Yusuf Vayisoğlu
DTDerya Ümit Talas
Derya Ümit Talas
Purpose: The main objective of the study was to evaluate the probable diversity in the area of the foramen magnum (FM) calculated by different measuring methods. Methods: The study was conducted on 24 dry skulls, present in the collection of the Anatomy Department, Faculty of Medicine, Mersin University. The area of FM was calculated by different measurement methods including automatic field setting, Teixeria and Radinsky formulas obtained from anatomic (ASM), photographic (PSM) and radiologic (RSM) skull measurements. Results: The areas of FMs calculated by Teixeria formula in RSM, PSM, and ASM were as follows: 857.96 ± 99.97 mm2, 796.68 ± 105.08 mm2, and 820.86 ± 96.40 mm2, respectively. The areas calculated by Radinsky formula in RSM, PSM, and ASM were as follows: 851.37 ± 99.68 mm2, 792.63 ± 104.18 mm2, and 814.85 ± 94.99 mm2, respectively. Lastly, the areas calculated by the automatic field setting of RSM and PSM software were as follows: 799.75 ± 103.38 mm2 and 752.83 ± 105.60 mm2, respectively. Conclusion: Statistical significance was observed between the areas of FM obtained from RSM, ASM, and PSM when calculated by the automatic field setting, Teixeria formula, and Radinsky formula. The authors think that considering the amorphous shape of FM, the automatic field setting of the software should be used to obtain the most accurate numerical data related to the area of FM.