Zhe Wang

Zhe Wang

Auto-generated profile, based on publicly available information

Zhe Wang

Changchun University of Science and Technology

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 January 2018 in Australasian Physics & Engineering Sciences in Medicine
Verified
Journal Article
Closed access
PDF file
ZWZhe Wang
Zhe Wang
YYYuanhua Yu
Yuanhua Yu
ZYZhanjiang Yu
Zhanjiang Yu
QCQimeng Chen
Qimeng Chen

4 December 2020
Verified
Conference Paper
Closed access
PDF file
XMXiangkai Meng
Xiangkai Meng
GJGuangyong Jin
Guangyong Jin
ZWZhe Wang
Zhe Wang
PGPing Gong
Ping Gong
LDLuyang Duanmu
Luyang Duanmu
With the continuous impact of COVID-19, the demand for rapid genetic diagnosing at the inspection and quarantine site, emergency treatment of sudden infectious diseases and clinical in vitro diagnosis was increasing rapidly. In order to achieve rapid, automatic nucleic acid extraction and detection, an automatic diagnostic system which integrates nucleic acid extraction, amplification and biochip fluorescence detection is designed. The diagnostic system designed based on multidisciplinary intersection of biology, optoelectronics, machinery and computer technology. At first, the nucleic acid extraction part has 1-8 sample flux and uses the principle of the silicon filter can adsorb nucleic acid at different pH to achieve nucleic acid extraction. After the extraction process, the nucleic acid is injected into biochip through robotic arm. There is a specific microarray reaction chamber on the chip, which can be combined with a specific biological substance; Secondly the amplification part used the principle of flat-plate PCR to achieve nucleic acid amplification in the biochip; After amplification, the nucleic acid detection realized under the irradiation of the excitation light at 530nm, the specificity target on the biochip will emit light, thus the fluorescence image scanned by COMS camera and the result analyzed by the software on PC; At last device control, automation and detection of the integrated device realized by the STM32 single-chip microcomputer and CAN communication method to establish a device communication network. The diagnostic system will automate workflow, and provides a result that reports on the detection and interpretation of targets in the samples. The imaging module resolution was less than 10 microns/pixel. The CV value of the sample was less than 10%. The results provide that the diagnostic system can provide more accurate and more automated equipment for nucleic acid extraction, amplification and detection.

12 April 2019 in Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine
Verified
Journal Article
Closed access
PDF file
ZWZhe Wang
Zhe Wang
YYYuan-Hua Yu
Yuan-Hua Yu
ZYZhan-Jiang Yu
Zhan-Jiang Yu
QCQi-Meng Chen
Qi-Meng Chen
Rapid detection techniques and methods of blood coagulation have attracted wide attention in academia and the business community in the presence of the increased demands for rapid assessment (point-of-care testing) of patients from surgery, intensive care unit, and other departments. The differential equation of vibration system composed of elastic support and electromagnetic induction devices was set up using the principle of damping vibration and establishing the dynamics model; meanwhile, the harmonic response analysis and vibration fatigue coupling analysis were carried out, the analysis results were optimized, and the experimental device of the electromagnetic induction testing sensor was established. In addition, the experimental device with blood coagulation reagent was assorted to establish the standard point-of-care testing rapid blood coagulation detection curve, and to compare the testing curve with that of the imported point-of-care testing blood coagulation instrument. The results showed that the first-order natural frequency of the designed sensor was 102.35 Hz, the correlation between the designed sensor and the imported equipment was 0.996, and the testing repeatability of the designed sensor could reach 0.002. Therefore, the designed blood coagulation testing sensor based on electromagnetic induction had the characteristics of favorable elasticity and anti-fatigue, which could meet the accuracy requirements of clinical detection. Taken together, this study could provide the core technology for developing the point-of-care testing instrument for blood coagulation dynamic testing.

26 April 2021 in Research Square
Verified
Preprint
Open access
PDF file
QCQimeng Chen
Qimeng Chen
ZLZibo Li
Zibo Li
ZLZiqi Liu
Ziqi Liu
QWQiong Wu
Qiong Wu
ZWZhe Wang
Zhe Wang
To solve the problem of monitoring the platelet functions in different stages during the arterial thrombosis process in a real-time and dynamic manner, this study aimed to propose a dual-channel in vitro coagulation dynamic whole-process detection sensing system to continuously monitor the changes in coagulation and platelet functions in patients with coronary atherosclerosis receiving oral administration of aspirin. Altogether 20 healthy subjects were randomly selected from the physical examination center. In addition, 20 patients with the initial diagnosis of coronary atherosclerosis who were naive to any antiplatelet drug therapy were also enrolled. After admission, the patients were administered with aspirin at 100 mg/day. For the healthy group, one single venous blood sample was collected from each of them. For the inpatients, they were given corresponding antiplatelet drug therapy, and venous blood samples were collected before administration (0 h), and at 6 h (6 h), 12 h (12 h), 18 h (18 h) and 24 h (24 h) after administration, respectively. Each blood sample was collected into the sodium citrate-containing anticoagulant blood collection tube. After each collection, the in vitro coagulation dynamic detection sensing system was used to detect each indicator. In the dual-channel in vitro coagulation dynamic whole-process detection sensing system developed in this study, one channel served as the experimental channel for patients with coronary atherosclerosis, which adopted the dry coagulation glass bead kit developed in this paper, where the thrombin was directly activated by the glass bead, and it was denoted as the nor channel. The other channel served as the blank control channel for the experimental channel, which adopted the dry coagulation glass bead kit developed in this study and was denoted as the non-channel. The normally distributed measurement data were expressed as means ± SD (x ̅±s) and compared by student’s t-test between two groups. Analysis of variance (ANOVA) was applied in comparisons before and after treatment (in the case of homogeneity of variance, the LSD method was applied in analysis; otherwise, the Dunnett’s C method was used for analysis). A difference of P<0.05 indicated statistical significance. ① Changes in the values of diverse parameters of nor-channel and non-channel in patients with coronary atherosclerosis before administration were different from the normal levels. On the whole, before administration, the activated clotting time (ACT) decreased, clot rate (CR) increased, and platelet factor (PF) increased, suggesting the abnormal platelet function in the blood of patients with coronary atherosclerosis. Meanwhile, after oral administration of aspirin, the changes in nor-channel showed not significant difference, indirectly indicating that the glass bead dry coagulation reagent developed in our previous study was the best coagulation activator. ② Patients with coronary atherosclerosis took aspirin for a long time (100 mg/day), and the maximum dose after admission was 300 mg/day. In these patients, the ACT increased, CR decreased, and PF declined. These changes were not significantly different compared with normal levels, suggesting that the increased dose was acceptable to patients, which might be used to guide clinical treatment. ③ For patients with the initial diagnosis of coronary atherosclerosis, the nor-channel and non-channel data were significantly different after oral administration of aspirin (100 mg/day). To be specific, ACT increased, CR decreased, and PF declined. The PF changes were not consistent with our expectation, but they might be ascribed to the small sample size, thus indirectly reflecting that thrombin activation by glass beads was the rapidest and best approach among the platelet activation pathways, which more sensitively and accurately evaluated the indicators for aspirin efficacy. This paper develops a new method to evaluate the in vitro antiplatelet drug efficacy based on the blood viscoelastic test. This method can evaluate platelet function in a rapider and easier manner; besides, it allows for the use of diverse bedside techniques, thereby displaying great application prospect in medicine and biomedical engineering.