Anik Kumar Samanta

Anik Kumar Samanta

Auto-generated profile, based on publicly available information

Anik Kumar Samanta

Advanced Technology Development Centre, IIT Kharagpur, Kharagpur, India

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 April 2016 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
ANArunava Naha
Arunava Naha
ASAnik Kumar Samanta
Anik Kumar Samanta
ARAurobinda Routray
Aurobinda Routray
ADAlok Kanti Deb
Alok Kanti Deb
This paper presents an effective method of motor current signature analysis for detecting half- as well as full broken single rotor bar fault of a squirrel-cage induction machine under various loading conditions and speeds. The proposed method is based on spectral preprocessing of the stator current followed by subspace decomposition of the signal autocorrelation matrix to detect relatively low-amplitude fault sidebands. This method is found to be very effective in detecting low-amplitude sinusoids in a signal dominated by high-amplitude fundamental. The extended Kalman filter is used to estimate and track the fundamental component of the stator current. This component is subtracted from the measured stator current at every time step generating a resultant signal with a very low or negligible fundamental component. Subsequently, multiple-signal classification (MUSIC) is applied on the resultant stator current signal. Motor slip is estimated from principle slot harmonic to decide the approximate location of the fault sidebands. For effective fault detection, a hypothesis test is proposed to check the presence of sufficient fault frequency sideband in the current spectrum. This test works better if the lobe in the MUSIC plot due to the fault frequency is not distorted or overlapped by the fundamental component. Therefore, for each data window, the minimum size of the autocorrelation matrix is determined to generate distinct peaks. The proposed method applies to steady-state condition and is found to exhibit superior performance even during the light-load conditions with a half-broken bar.

1 January 2018 in Renewable Energy
Verified
Journal Article
Closed access
CPChittaranjan Pradhan
Chittaranjan Pradhan
CBChandrashekhar Narayan Bhende
Chandrashekhar Narayan Bhende
ASAnik Kumar Samanta
Anik Kumar Samanta

1 January 2018 in Mechanical Systems and Signal Processing
Verified
Journal Article
Closed access
ASAnik Kumar Samanta
Anik Kumar Samanta
ANArunava Naha
Arunava Naha
ARAurobinda Routray
Aurobinda Routray
ADAlok Kanti Deb
Alok Kanti Deb

16 January 2015 in IEEE Transactions on Power Delivery
Verified
Journal Article
Closed access
AMAyan Mukherjee
Ayan Mukherjee
ARAurobinda Routray
Aurobinda Routray
ASAnik Kumar Samanta
Anik Kumar Samanta
This paper presents an algorithm for online detection of arcing in low-voltage (230 V, 50 Hz) distribution systems. Electromagnetic radiation has been used as a feature for discrimination between arc and nonarc signals. The output of the electromagnetic radiation sensor has been analyzed in the spectral domain using the log-spectral distance metric for the detection of arcing. For validation of this method, a testbench comprising an arc generation setup has been developed in the laboratory. The algorithm has been tested against arc and arc-mimicking normal signals using the testbench to validate its effectiveness. Further, the algorithm is implemented online using xPC target (an embedded platform) for studying the feasibility and accuracy of its online implementation. A system based on this method can continuously monitor the health of a distribution network and, thus, can be very helpful in safeguarding against fire hazards due to electric arcing.

29 August 2017 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
ANArunava Naha
Arunava Naha
ASAnik Kumar Samanta
Anik Kumar Samanta
ARAurobinda Routray
Aurobinda Routray
ADAlok Kanti Deb
Alok Kanti Deb
Motor current signature analysis requires high sampling rate and a large number of data samples to detect faults at light loading conditions. However, it would be interesting to investigate the alternative methods to bring down these requirements using the principle of sparse signal processing. In this paper, a low-complexity fault detection algorithm based on the sub-Nyquist sampling of the analytic current signal has been proposed and compared to other similar algorithms. The acquired current data is first converted into an analytic signal using a low-cost time-shift-based method. The processing of the analytic current signal has been performed at a rate 20 times lower than the Nyquist criterion using multicoset sampling technique. The computational complexity has been reduced further by partially reconstructing the spectrum only for the regions of interest. The regions of interest were found out from the estimated supply frequency and the armature current magnitude. The supply frequency has been estimated from the transformed analytic current signal. The algorithm has been tested for broken rotor bar (BRB), eccentricity, and broken bearing faults, using the recorded data from a 22-kW induction motor drive at various loading conditions in the laboratory. In addition, the BRB fault has also been tested for motors with 1.5- and 3.7-kW ratings. A receiver operating characteristic curve has been generated to test the performance of the algorithm. The proposed algorithm uses only a single current sensor to acquire one of the armature phase currents.

1 January 2021 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
ASAnik Kumar Samanta
Anik Kumar Samanta
ARAurobinda Routray
Aurobinda Routray
SKSwanand R. Khare
Swanand R. Khare
ANArunava Naha
Arunava Naha
In this article, we propose a single-vibration sensor-based method for detecting incipient faults in squirrel cage induction motors (SCIMs). We consider defects in different parts of the bearing (inner raceway, outer raceway, cage train, and rolling element) and in a single bar of the rotor. The vibration signal is dominated by the fundamental rotational frequency and its harmonics. The dominant components result in numerical errors while estimating the relatively indistinct fault-specific spectral components. In this article, we precondition the vibration signal by suppressing multiple dominant components using an extended Kalman filter-based method. The suppression of the dominant components reduces the spectral leakage, exposes minute fault components, and improves the overall amplitude estimation. Subsequently, we estimate the fault frequency and amplitude using an accurate and low-complexity Rayleigh-quotient-based spectral estimator. The thresholds for fault detection are determined from a small number of healthy data, and an adaptive minimum distance-based detector is used for hypothesis testing. The proposed test improves detection and reduces false alarms under noisy conditions. We test the complete algorithm using data from a 22-kW SCIM laboratory setup. The proposed method has achieved 100% accuracy with the publicly available 12-kHz drive-end bearing data from Case Western Reserve University, Cleveland, OH, USA.