Igor I. Bezukladnikov

Igor I. Bezukladnikov

Auto-generated profile, based on publicly available information

Igor I. Bezukladnikov

Пермский национальный исследовательский политехнический университет

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 June 2023 in Russian Journal of Dentistry
Verified
Journal Article
Closed access
SASergey Arutyunov
Sergey Arutyunov
AYAleksandr A. Yuzhakov
Aleksandr A. Yuzhakov
YKYaser Kharakh
Yaser Kharakh
IBIgor I. Bezukladnikov
Igor I. Bezukladnikov
ABAndrey A. Baidarov
Andrey A. Baidarov
ХНХарах Ясер Насерович
Харах Ясер Насерович
The study reflects the current trends in the digital format of educational technology in dentistry, which is a new paradigm in the training of medical personnel. The new-generation dental simulator is presented as an innovation in the educational process. The authors propose technically combining the accumulated positive solutions in this area using a single hardware and software environment, i.e., an anthropomorphic robot, whose hardware platform is expanded with additional specialized sensors and actuators. To increase the practical competencies of dental students and dentists when honing practical skills, the use of a dental simulator based on a robotic complex in the educational process is the most optimal way by creating a fully functional anthropomorphic dental robot, especially with integrated modules Smart-Jaw and Smart Teeth and supporting the communicative function through artificial intelligence. Currently, a fully functional prototype of the anthropomorphic robot simulator Promobot-Ct with a set of educational cases has been utilized, which is used to train dentists at Perm State Medical University, which was named after Academician E.A. Vagner.

27 December 2022 in Parodontologiya
Verified
Journal Article
Open access
PDF file
SASergey Arutyunov
Sergey Arutyunov
AYA. A. Yuzhakov
A. A. Yuzhakov
YKYaser Kharakh
Yaser Kharakh
IBI. I. Bezukladnikov
I. I. Bezukladnikov
NAN. B. Astashina
N. B. Astashina
ЯХЯ. Н. Харах
Я. Н. Харах
Relevance. The success and progress of medical education are inherently linked to the achievements of fundamental and applied sciences and depend on the degree of curriculum fulfilment with advanced digital technology effectiveness. The article considers new forms of learning organization based on digital platforms. Information and communication technologies (platforms) allow effective distant coordination of the academic paths for large numbers of students and strict unbiased control over the implementation of assigned tasks. The article considers the specific features of medical digital platforms, algorithmic management forms, necessity and importance of cyber-physical systems, and gives examples of single robotic element implementation used in learning platf orms.Materials and Methods. The publication selection criteria were: papers published after 2000; relevance to the keywords "Education", "Medical Education", and "Patient Simulation"; publications included in the databases "ScienceDirect" (Scopus), "IEEE", or "NCBI".Results. Twenty-seven scientific publications were selected by the inclusion and exclusion criteria.Conclusion. The online learning platform formed by a set of transformed traditional curricula allows for a full access of students to learning resources and can stimulate the teaching staff competencies, which is, in general, a relevant and promising direction for improving the effectiveness of the learning process.

16 February 2024 in Vestnik of Volga State University of Technology. Series Radio Engineering and Infocommunication Systems
Verified
Journal Article
Closed access
SASergey Arutyunov
Sergey Arutyunov
АЮА.а. Южаков
А.а. Южаков
ИБИ.и. Безукладников
И.и. Безукладников
НАН.б. Асташина
Н.б. Асташина
АЕА.м. Еловиков
А.м. Еловиков
ПМП.в. Майоров
П.в. Майоров
В статье рассматривается влияние конструктивных параметров системы «звуковой излучатель – ушной имплант» бионического протеза уха на результирующие звуковые характеристики – АЧХ, ФЧХ, субъективное качество восприятия звука пациентом (перцептивность). В предыдущих исследованиях авторского коллектива показано, что ряд механических параметров крепления бионического протеза (расстояние и угол между крепёжными элементами) не оказывает значимого влияния на результирующую характеристику, однако существуют иные факторы, оказывающие такое влияние. По итогам проведённого расширенного анализа полученных в ходе предыдущих экспериментов звуковых характеристик авторами в качестве гипотезы были определены две основные потенциальные причины их изменения – качество прижимного соединения непосредственно между звуковым излучателем и ушным имплантом, а также возникающий в процессе неоптимального механического крепления общий перекос конструкции «виброизлучатель – тело протеза» относительно осевой линии ушного импланта. В настоящей статье авторами для подтверждения выдвинутой гипотезы проведены дополнительные эксперименты по выявлению реального влияния указанных выше факторов на звуковые характеристики. Выявлена высокая степень влияния особенностей прижимного соединения непосредственно между звуковым излучателем и ушным имплантом на результирующие АЧХ и ФЧХ. Подтверждены причины возникновения дефектов АЧХ, наблюдавшихся в предыдущих экспериментах, а также определены основные меры противодействия ухудшению звуковых характеристик бионического уха за счёт оптимизации соответствующих конструктивных элементов. Introduction. Specialized hearing aids utilizing bone conduction are gaining popularity for restoring hearing in patients facing various challenges, such as traumatic ear amputation or congenital anomalies. These devices prove beneficial even when surgery might not be the optimal solution, especially considering the patient's age. An alternative to conventional head-mounted devices comes in the form of a bionic ear seamlessly integrated into an aesthetic prosthesis, doubling as a hearing aid. However, a significant scientific challenge lies in effectively transmitting sound through a complex system comprising an implant, a vibrating transducer, and the patient's bone tissue. This system, marked by substantial nonlinearity, multiple transitions between media, and various parameters, may suffer from resonances and delays at different frequencies. Addressing this scientific challenge aims at enhancing sound transmission quality and increase the efficiency of such hearing aids. The aim of this study is to investigate the impact of the clamping connection parameters of the "sound emitter-ear implant" system, along with associated mechanical fastening parameters, on sound signal characteristics to optimize the prosthesis's mechanical design. Conclusion. The study unveiled that employing an optimized retainer design, coupled with the overall optimization of the prosthesis geometry, significantly enhances its acoustic characteristics. The resultant amplitude-frequency and phase-frequency responses after optimization deliver high perceptual sound quality. Furthermore, our findings indicate that employing polyetherketone compounds serves as a compelling alternative to traditional frame materials, offering both high rigidity and a lighter, more workable structure. The refined frame design enhances the contact of the vibration emitter with the bone substrate, thereby improving sound signal characteristics.

20 November 2023 in Vestnik of Volga State University of Technology. Series Radio Engineering and Infocommunication Systems
Verified
Journal Article
Closed access
SASergey Arutyunov
Sergey Arutyunov
АЮА.а. Южаков
А.а. Южаков
ИБИ.и. Безукладников
И.и. Безукладников
НАН.б. Асташина
Н.б. Асташина
АЕА.м. Еловиков
А.м. Еловиков
ПМП.в. Майоров
П.в. Майоров
В статье выполнен анализ амплитудно-частотных и временных показателей предлагаемого научно-исследовательской группой технологического решения для реализации проекта по разработке «бионического протеза ушной раковины». Целью работы является изучение влияния параметров крепления бионического уха на характеристики звукового сигнала для дальнейшего определения оптимального положения имплантатов. Для решения поставленных задач был создан тестовый стенд, на котором выполнены экспериментальные исследования, на основании полученных данных сделаны выводы об отсутствии влияния геометрических расстояний между элементами протеза на АЧХ сигнала, а также о необходимости доработки механизма крепления виброизлучателя. Introduction. The occurrence of microtia, which includes anotia, is found in approximately 4.53 cases per 10,000 newborns [1]. As a result, most patients suffer from partial or complete hearing loss, as well as stenosis or atresia of the auditory canal [2–4]. Surgical intervention is one method employed to restore hearing, although its feasibility can vary depending on the patients' age or, in some cases, the degree of atresia [4–7]. Patients also turn to alternative methods of rehabilitation, such as bone-anchored hearing aids, which facilitate sound transmission through bone conduction. These devices often yield progressive or even superior results in terms of hearing restoration [8–11]. The aim of this study is to examine how the attachment parameters of the bionic ear affect the characteristics of the sound signal. This analysis will help identify the optimal position for the implants. The team of authors has created a bionic ear that not only restores the function of the ear but also enhances facial aesthetics [18–22]. This innovative system combines several components into one unified design: an ear prosthesis, a magnetic beam fixation system for attaching the prosthesis to osseointegrated extraoral implants, a microphone, and an audio processing unit equipped with a specialized digital signal processor (DSP) along with analog-to-digital and digital-to-analog converters. During the development of this technology, a significant challenge was understanding how sound quality is transmitted through the complex "implant – vibration emitter – patient's bone tissue" system. This system is highly nonlinear, involving multiple transitions between different materials with varying sound properties, such as speed and density, leading to resonances and delays across different frequencies. Results. This article investigates a critical factor affecting acoustic characteristics, which is the specific distances between the mechanical attachments of key components in the bionic ear. It analyzes how these fundamental distances impact acoustic characteristics. Additionally, the article outlines the experimental approach and the setup of a custom-designed experiment station. This station enables the evaluation of the acoustic performance of the "bionic prosthesis-vibration emitter-implant" system under acoustically challenging conditions that closely resemble real-world scenarios. Conclusion.Hence, the research indicates that altering the distance between the mounts of the bionic ear has an insignificant impact on its sound-reproduction capabilities. The customization of bionic design based on the individual patient's characteristics is a more elaborate process. It's worth noting that the choice of materials for the bionic ear's frame does have a positive effect. Using materials with a high degree of rigidity for the frame can lead to vibration emitter suspension deformation during prosthesis installation. Similarly, the quality of securing the vibration emitter to the bone implant is critical.