Xuesong Han

Xuesong Han

Auto-generated profile, based on publicly available information

Xuesong Han

Anhui Key Laboratory of Industry Safety and Emergency Technology

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 January 2024 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
ZGZheng Gong
Zheng Gong
Xuezhi YangXuezhi Yang
Xuezhi Yang
RSRencheng Song
Rencheng Song
XHXuesong Han
Xuesong Han
CRChong Ren
Chong Ren
WLWei Li
Wei Li
Remote photoplethysmography (rPPG) enables heart rate (HR) measurement under stable illumination and low noise conditions. However, challenges arise due to rapid lighting changes, significant head movements, and vehicle vibrations during driving, impacting the recovery of clear rPPG signals and rendering denoising techniques alone inadequate in entirely eliminating noise interference. To address these challenges, we introduce an innovative approach, “quality-guided spectrum peak screening” (QSPS), for monitoring the driver’s HR during driving. First, we developed a signal evaluation framework for assessing signal quality across multiple facial regions following wavelet filtering. Subsequently, by leveraging quality information, a spectral peak screening algorithm is applied to signals from multiple regions, mitigating the impact of residual noise on rPPG. The precise HR is determined by integrating quality scores and short-term stability from various facial regions. Our method is employed in a commercially available driver monitoring system (DMS) equipped with a monochrome camera. Test results show QSPS’s robustness compared with established near-infrared (NIR)-based HR detection methods. In driving scenarios, QSPS achieves a mean absolute error (MAE) of 4.32 bpm, a root mean square error (RMSE) of 6.15 bpm, and a percentage of time with HR estimation errors smaller than 6 bpm of 68.8%. Furthermore, QSPS exhibits excellent performance during extended 10-min HR monitoring, with a Pearson correlation coefficient of 0.943 in the night test and 0.906 in the day test.

19 June 2023 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
XHXuesong Han
Xuesong Han
Xuezhi YangXuezhi Yang
Xuezhi Yang
SFShuai Fang
Shuai Fang
RSRencheng Song
Rencheng Song
LLLongwei Li
Longwei Li
JZJie Zhang
Jie Zhang
Objective : The tiny change of skin color, caused by heartbeat, can be captured with consumer-level cameras by using the imaging photoplethysmography (iPPG) technique, offering a non-contact way of extracting pulse signals. The pulse signals have been demonstrated to contain information of human physiological characteristics and have been used for blood pressure (BP) estimation in recent years. According to BP-related cardiovascular knowledge, this paper presents a new method for BP estimation based on the iPPG pulse signals, featured by incorporating cardiovascular characteristics including heart rate (HR), stroke volume (SV), elasticity of vessel walls (EVW), and peripheral vascular resistance (PVR). Correlations between the systolic blood pressure (SBP), diastolic blood pressure (DBP), pulse pressure (PP), and the cardiovascular characteristics are extracted, which facilitates the selection of pulse features consistent with BP properties. Based on the selected features, two Bayesian neural network (BNN) models are constructed for the estimation of SBP and DBP respectively, where the machine learning (ML) uncertainty of the estimation is also evaluated. This method is uncalibrated that means it can work without additional information except for the videos from the camera. The proposed method has been tested on 220 patients with a history of cardiovascular diseases. Errors of the BP estimation are 9±13 (MAE±STD) mmHg for SBP, 7±10 (MAE±STD) mmHg for DBP, and the ML uncertainty of the estimation indicates reliability of the proposed method.

15 March 2024 in Biomedical Optics Express
Verified
Journal Article
Closed access
XHXuesong Han
Xuesong Han
Xuezhi YangXuezhi Yang
Xuezhi Yang
SFShuai Fang
Shuai Fang
YCYawei Chen
Yawei Chen
QCQin Chen
Qin Chen
RSRenCheng Song
RenCheng Song
In recent years, imaging photoplethysmograph (iPPG) pulse signals have been widely used in the research of non-contact blood pressure (BP) estimation, in which BP estimation based on pulse features is the main research direction. Pulse features are directly related to the shape of pulse signals while iPPG pulse signals are easily disturbed during the extraction process. To mitigate the impact of pulse feature distortion on BP estimation, it is necessary to eliminate interference while retaining valuable shape details in the iPPG pulse signal. Contact photoplethysmograph (cPPG) pulse signals measured at rest can be considered as the undisturbed reference signal. Transforming the iPPG pulse signal to the corresponding cPPG pulse signal is a method to ensure the effectiveness of shape details. However, achieving the required shape accuracy through direct transformation from iPPG to the corresponding cPPG pulse signals is challenging. We propose a method to mitigate this challenge by replacing the reference signal with an average cardiac cycle (ACC) signal, which can approximately represent the shape information of all cardiac cycles in a short time. A neural network using multi-scale convolution and self-attention mechanisms is developed for this transformation. Our method demonstrates a significant improvement in the maximal information coefficient (MIC) between pulse features and BP values, indicating a stronger correlation. Moreover, pulse signals transformed by our method exhibit enhanced performance in BP estimation using different model types. Experiments are conducted on a real-world database with 491 subjects in the hospital, averaging 60 years of age.