1 August 2011 in Review of Scientific Instruments
The design and performance of the new cold neutron chopper spectrometer (CNCS) at the Spallation Neutron Source in Oak Ridge are described. CNCS is a direct-geometry inelastic time-of-flight spectrometer, designed essentially to cover the same energy and momentum transfer ranges as IN5 at ILL, LET at ISIS, DCS at NIST, TOFTOF at FRM-II, AMATERAS at J-PARC, PHAROS at LANSCE, and NEAT at HZB, at similar energy resolution. Measured values of key figures such as neutron flux at sample position and energy resolution are compared between measurements and ray tracing Monte Carlo simulations, and good agreement (better than 20% of absolute numbers) has been achieved. The instrument performs very well in the cold and thermal neutron energy ranges, and promises to become a workhorse for the neutron scattering community for quasielastic and inelastic scattering experiments.
1 June 2012 in Journal of Molecular Biology
9 August 2012 in Langmuir
4 March 1985 in Physical Review Letters
The inelastic scattering of neutrons by liquid at 0.2 K and saturated vapor pressure has been measured for momentum transfers in the range 10 A<Q<16 A. The observed scattering function is well described, within statistical uncertainties, by a Gaussian centered at the recoil energy. The average kinetic energy per atom, obtained from the width of the scattering function, is K.
1 June 1990 in Physical Review B
Deep-inelastic neutron scattering measurements on liquid have been carried out for temperatures from 0.35 to 4.2 K at a density of 0.147 g/. These measurements have a relative resolution comparable to previous reactor measurements, but at a momentum transfer of 23 A. This momentum transfer is sufficiently high that the differences between the observed scattering and that predicted by the impulse approximation are small and are well described by a recent theoretical treatment allowing direct information on the single-particle momentum distribution to be obtained from the scattering measurements. The scattering in the normal liquid phase is broad and featureless with a nearly Gaussian shape. The scattering in the superfluid phase is distinctly non-Gaussian with extra intensity at the peak center consistent with the presence of a Bose condensate. However, no distinct peak due to the Bose condensate is observed even when the effects of instrumental broadening are included. When deviations from the impulse approximation are taken into account using a recent theory, the experimental results at 0.35 K are in excellent agreement with ab initio ground-state variational and Green’s-function Monte Carlo calculations in the superfluid at T=0 K. The results at higher temperatures are in excellent agreement with recent path-integral Monte Carlo calculations in both the normal and superfluid phases. Fits of model functions to the scattering are also presented. The average kinetic energy per atom has been determined and is in good agreement with theoretical predictions and with previous experimental results.
1 March 2008 in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment