Wenshang Guo

Wenshang Guo

Auto-generated profile, based on publicly available information

Wenshang Guo

State Key Laboratory of Robotics and System, Harbin Institute of Technology, Harbin 150001, China

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 November 2024 in Science Advances
Verified
Journal Article
Open access
WGWenshang Guo
Wenshang Guo
YTYe Tao
Ye Tao
RYRuizhe Yang
Ruizhe Yang
KMKaihao Mao
Kaihao Mao
HZHongwei Zhou
Hongwei Zhou
Yukun RenYukun Ren
Yukun Ren
Developing instant detection systems with disease diagnostic capabilities holds immense importance for remote or resource-limited areas. However, the task of creating these systems—which are simultaneously easy to operate, rapid in detection, and cost-effective—remains a challenge. In this study, we present a compact highly sensitive photothermal reverse transcriptase–loop-mediated isothermal amplification (RT-LAMP) chip (SPRC) designed for the detection of multiple diseases. The nucleic acid (NA) amplification on the chip is achieved through LAMP driven by either LED illumination or simple sunlight focusing. SPRC performs sample addition and amplification within a limited volume and autonomous enrichment of NA during the sample addition process, achieving a limit of detection (LOD) as low as 0.2 copies per microliter. Through 120 clinical samples, we achieved an accuracy of 95%, with a specificity exceeding 97.5%. Overall, SPRC has achieved promising progress in the application of point-of-care testing (POCT) by using light energy to simultaneously detect multiple diseases.

8 August 2025 in Science Advances
Verified
Journal Article
Open access
WGWenshang Guo
Wenshang Guo
MXMinghui Xu
Minghui Xu
YTYe Tao
Ye Tao
WLWeiyu Liu
Weiyu Liu
HZHongwei Zhou
Hongwei Zhou
Yukun RenYukun Ren
Yukun Ren
Rapid and accurate disease diagnosis in resource-limited settings is critical for optimizing medical resources and controlling epidemic outbreaks. However, developing a point-of-care detection system that is user-friendly, cost-effective, highly accurate, and exhibits strong specificity remains a formidable challenge. Here, we report an integrated horizontal convection PCR system (IHCS) for clinical point-of-care testing, capable of real-time fluorescence detection. IHCS leverages horizontal thermal convection within a capillary to drive sample flow and temperature cycling for nucleic acid amplification, making it suitable for both home use and on-site rapid detection. Capillary action enables swift sample loading, thereby simplifying the overall procedure, and the horizontal thermal convection overcomes the volume limitations inherent in vertical systems. Validation with 130 clinical samples demonstrated that the system successfully detected HBV, SARS-CoV-2, and influenza A virus within 40 min, achieving excellent sensitivity (>96%) and specificity (100%). Overall, the IHCS integrates microfluidics, thermal engineering, and optical sensing and offers a paradigm-shifting solution for point-of-care diagnostics.

31 December 2024 in Sensors and Actuators B: Chemical
Verified
Journal Article
Closed access
KMKaihao Mao
Kaihao Mao
YTYe Tao
Ye Tao
WGWenshang Guo
Wenshang Guo
CSChangrui Shi
Changrui Shi
XZXiao Zhang
Xiao Zhang
Yukun RenYukun Ren
Yukun Ren