Tristan Putzeys

Tristan Putzeys

Auto-generated profile, based on publicly available information

Tristan Putzeys

KU Leuven, Medicine, Neurosciences, Leuven, Belgium

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 December 2015 in The Journal of Chemical Physics
Verified
Journal Article
Closed access
PDF file
AKA. Kasina
A. Kasina
TPT. Putzeys
T. Putzeys
MWM. Wübbenhorst
M. Wübbenhorst
Recently [S. Capponi, S. Napolitano, and M. Wübbenhorst, Nat. Commun. 3, 1233 (2012)], vapor deposited glasses of glycerol have been found to recover their super-cooled liquid state via a metastable, ordered liquid (MROL) state characterized by a tremendously enhanced dielectric strength along with a slow-down of the relaxation rate of the structural relaxation. To study the calorimetric signature of this phenomenon, we have implemented a chip-based, differential AC calorimeter in an organic molecular beam deposition setup, which allows the simultaneous measurement of dielectric relaxations via interdigitated comb electrodes and specific heat relaxation spectra during deposition and as function of the temperature. Heating of the as-deposited glass just above the bulk Tg and subsequent cooling/reheating revealed a step-wise increase in cp by in total 9%, indicating unambiguously that glycerol, through slow vapour deposition, forms a thermodynamically stable glass, which has a specific heat as low as that of crystalline glycerol. Moreover, these glasses were found to show excellent kinetic stability as well as evidenced by both a high onset-temperature and quasi-isothermal recovery measurements at −75 °C. The second goal of the study was to elucidate the impact of the MROL state on the specific heat and its relaxation to the super-cooled state. Conversion of “MROL glycerol” to its “normal” (ordinary liquid, OL) state revealed a second, small (∼2%) increase of the glassy cp, a little gain (<10%) in the relaxed specific heat, and no signs of deviations of τcal from that of normal “bulk” glycerol. These findings altogether suggest that the MROL state in glycerol comprises largely bulk-type glycerol that coexist with a minor volume fraction (<10%) of PVD-induced structural anomalies with a crystal-like calorimetric signature. Based on the new calorimetric findings, we have proposed a new physical picture that assumes the existence of rigid polar clusters (RPCs) and conclusively explains the extraordinary high kinetic stability of the MROL state, its specific calorimetric signature, the enhanced strength, and apparent slow-down of the dielectric α-relaxation. In this new picture, the incredibly slow and strengthened dielectric response is ascribed to driven rotational diffusion of whole RPCs, a mechanism that perfectly couples to the relaxation time of the “normal” glycerol fraction. First considerations based on the strength and the retardation of the dielectric RPCs’ response yield independently a size estimate for the RPCs in the order of 4-5 nm. Finally, we have discussed possible crystallisation and reorganisation effects, which give rise to pronounced out-of phase components of the specific heat at higher temperatures.

29 May 2022 in Hearing Research
Verified
Journal Article
Open access
TPTristan Putzeys
Tristan Putzeys
CBCharlotte Borgers
Charlotte Borgers
GFGuy Fierens
Guy Fierens
JWJoris Walraevens
Joris Walraevens
AWAstrid van Wieringen
Astrid van Wieringen
NVNicolas Verhaert
Nicolas Verhaert
The generally accepted method to assess the functionality of novel bone conduction implants in a preclinical stage is to experimentally measure the vibratory response of the cochlear promontory. Yet, bone conduction of sound is a complex propagation phenomenon, depending on both frequency and amplitude, involving different conduction pathways. The aim of this study is to validate the use of intracochlear sound pressure (ICP) as an objective indicator for perceived loudness for bone conduction stimulation. It is investigated whether a correlation exists between intracochlear sound pressure measurements in cadaveric temporal bones and clinically obtained results using the outcome of a loudness balancing experiment. Ten normal hearing subjects were asked to balance the perceived loudness between air conducted (AC) sound and bone conducted (BC) sound by changing the AC stimulus. Mean balanced thresholds were calculated and used as stimulation levels in a cadaver trial (N = 4) where intracochlear sound pressure was measured during AC and BC stimulation to assess the correlation with the measured clinical data. The intracochlear pressure was measured at the relatively low stimulation amplitude of 80 dBHL using a lock-in amplification technique. Applying AC and BC stimulation at equal perceived loudness on cadaveric heads yield a similar differential intracochlear pressure, with differences between AC and BC falling within the range of variability of normal hearing test subjects. Comparing the perceived loudness at 80 dB HL for both AC and BC validates intracochlear pressure as an objective indicator of the cochlear drive. The measurement setup is more time-intensive than measuring the vibratory response of the cochlear promontory, yet it provides direct information on the level of the cochlear scalae.

28 December 2022 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
LKLore Kerkhofs
Lore Kerkhofs
ASAnastasiya Starovoyt
Anastasiya Starovoyt
JWJan Wouters
Jan Wouters
TPTristan Putzeys
Tristan Putzeys
NVNicolas Verhaert
Nicolas Verhaert
Advancements in intracochlear diagnostics, as well as prosthetic and regenerative inner ear therapies, rely on a good understanding of cochlear microanatomy. The human cochlea is very small and deeply embedded within the densest skull bone, making nondestructive visualization of its internal microstructures extremely challenging. Current imaging techniques used in clinical practice, such as MRI and CT, fall short in their resolution to visualize important intracochlear landmarks, and histological analysis of the cochlea cannot be performed on living patients without compromising their hearing. Recently, optical coherence tomography (OCT) has been shown to be a promising tool for nondestructive micrometer resolution imaging of the mammalian inner ear. Various studies performed on human cadaveric tissue and living animals demonstrated the ability of OCT to visualize important cochlear microstructures (scalae, organ of Corti, spiral ligament, and osseous spiral lamina) at micrometer resolution. However, the interpretation of human intracochlear OCT images is non-trivial for researchers and clinicians who are not yet familiar with this novel technology. In this study, we present an atlas of intracochlear OCT images, which were acquired in a series of 7 fresh and 10 fresh-frozen human cadaveric cochleae through the round window membrane and describe the qualitative characteristics of visualized intracochlear structures. Likewise, we describe several intracochlear abnormalities, which could be detected with OCT and are relevant for clinical practice.

1 January 2022 in BioMed Research International
Verified
Journal Article
Open access
PDF file
GFGuy Fierens
Guy Fierens
CBCharlotte Borgers
Charlotte Borgers
TPTristan Putzeys
Tristan Putzeys
JWJoris Walraevens
Joris Walraevens
AWAstrid van Wieringen
Astrid van Wieringen
NVNicolas Verhaert
Nicolas Verhaert
Active transcutaneous bone conduction (BC) devices offer the benefit of improved power output compared to passive transcutaneous devices and remove the risk of skin infections that are more common in traditional percutaneous BC devices. Despite these advantages, more research is needed on implant location, device coupling, and their influence on device performance. This study is aimed at quantifying the extent to which certain parameters affect device output when using the Osia® system actuator. Parameters under study are (1) implant location, (2) comparison with the actuator of a state‐of‐the‐art BC device, (3) bone undergrowth simulation, and (4) skull fixation. Five human cadaveric heads were implanted with the actuator at three different implant locations: (1) recommended, (2) posterior Osia® positions, and (3) standard Baha® position. At each location, the cochlear promontory velocity and the intracochlear pressure difference were measured. A percutaneous bone conduction actuator was used as a reference for the obtained measurements. Stimulation levels corresponded to a hearing level of 60 dB HL for frequencies between 250 and 6000 Hz. In addition, bone cement was used as a simulation for reactive bone growth. Results obtained in four heads indicate an improved power transmission of the transcutaneous actuator when implanted at the recommended position compared to the actuator of the percutaneous device on its respective recommended location when stimulating at an identical force level. A correlation was found between the promontory vibration and the actuator position, indicating that the same level of stimulation leads to higher promontory vibrations when the device is implanted closer to the ear canal. This is mainly reflected at frequencies higher than 1 kHz, where an increase was observed in both measurement modalities. At lower frequencies (<1 kHz), the power transmission is less influenced by the implant position and differences between the acquired responses are limited. In addition, when no rigid coupling to the skull is provided, power transfer losses of up to 30 dB can be expected.

15 June 2020 in The Journal of Chemical Physics
Verified
Journal Article
Closed access
PDF file
HPHailong Pan
Hailong Pan
PGPieter Geysens
Pieter Geysens
TPTristan Putzeys
Tristan Putzeys
AGAlessia Gennaro
Alessia Gennaro
YYYingting Yi
Yingting Yi
MWMichael Wübbenhorst
Michael Wübbenhorst
The protic ionic liquid diethylmethylammonium methanesulfonate ([DEMA][OMs]) was analyzed in depth by differential scanning calorimetry (DSC), nuclear magnetic resonance (NMR) spectroscopy, Fourier transform infrared (FT-IR) spectroscopy, Raman spectroscopy, and broadband dielectric spectroscopy (BDS) under anhydrous conditions. Karl Fischer titration, NMR, and FT-IR spectra confirmed the high purity of [DEMA][OMs]. The melting point (37.7 °C) and the freezing point (14.0 °C) obtained by DSC agree well with the values determined by BDS (40.0 °C and 14.0 °C). The dc conductivity (σdc) above the melting/freezing point obeys the Vogel–Fulcher–Tammann (VFT) equation well, and thus, the proton conduction in [DEMA][OMs] is assumed to be dominated by the vehicle mechanism. In contrast, the σdc below the melting/freezing point can be fitted by the Arrhenius equation separately, and therefore, the proton conduction is most likely governed by the proton hopping mechanism. The non-negligible influence of previously reported low water content on the physicochemical properties of [DEMA][OMs] is found, indicating the importance of reducing water content as much as possible for the study of “intrinsic” properties of protic ionic liquids.

1 June 2024 in Hearing Research
Verified
Journal Article
Open access
AGAlexander Geerardyn
Alexander Geerardyn
IWIrina Wils
Irina Wils
TPTristan Putzeys
Tristan Putzeys
GFGuy Fierens
Guy Fierens
JWJan Wouters
Jan Wouters
NVNicolas Verhaert
Nicolas Verhaert
The round window (RW) membrane plays an important role in normal inner ear mechanics. Occlusion or reinforcement of the RW has been described in the context of congenital anomalies or after cochlear implantation and is applied as a surgical treatment for hyperacusis. Multiple lumped and finite element models predict a low-frequency hearing loss with air conduction of up to 20 dB after RW reinforcement and limited to no effect on hearing with bone conduction stimulation. Experimental verification of these results, however, remains limited. Here, we present an experimental study measuring the impact of RW reinforcement on the middle and inner ear mechanics with air and bone conduction stimulation. In a within-specimen repeated measures design with human cadaveric specimens (n = 6), we compared the intracochlear pressures in scala vestibuli (PSV) and scala tympani (PST) before and after RW reinforcement with soft tissue, cartilage, and bone cement. The differential pressure (PDIFF) across the basilar membrane - known to be closely related to the hearing sensation - was calculated as the complex difference between PSV and PST. With air conduction stimulation, both PSV and PSTincreased on average up to 22 dB at frequencies below 1500 Hz with larger effect sizes for PST compared to PSV. The PDIFF, in contrast, decreased up to 11 dB at frequencies between 700 and 800 Hz after reinforcement with bone cement. With bone conduction, the average within-specimen effects were less than 5 dB for either PSV, PST, or PDIFF. The inter-specimen variability with bone conduction, however, was considerably larger than with air conduction. This experimental study shows that RW reinforcement impacts air conduction stimulation at low frequencies. Bone conduction stimulation seems to be largely unaffected. From a clinical point of view, these results support the hypothesis that delayed loss of air conduction hearing after cochlear implantation could be partially explained by the impact of RW reinforcement.