The Kirchhoff double-scatter method for calculating the intensity distribution scattered from a rough surface is extended to dielectric and metal surface materials. The material properties are contained in the Fresnel reflection coefficients only. It is shown that the results agree well with calculations using the exact method for a surface of Gaussian statistics with standard deviation of height σ = 1·93λ and 1/e correlation length τ = 5·02λ.
A method for using liquid-crystal variable retarders (LCVRs) with continually varying voltage to measure the complete Mueller matrix of a general sample is presented. The LCVRs are usually employed with fixed retardance values due to the nonlinear voltage–retardance behavior that they show. For the measurement method presented here, the nonlinear voltage–retardance relationship is first measured, and then a linear fit of the known retardance terms to the detected signal is performed. For a gap of air, the measurement error in the Mueller-matrix polarimeter is estimated at 1%–10%, depending on the Mueller-matrix element. Also, we present experimental results for a Glan–Thompson prism polarizer as a test sample, and we use the measured Mueller parameters as functions of the orientation of the optical axes of the polarizer as an indication of the quality of the polarimeter. In addition, results are compared to a typical step-voltage method to measure the Mueller matrix. Both methods give good results.
We present the analysis and implementation of a set of experimental procedures to characterize optical polarization properties as a function of the applied voltage for liquid-crystal variable retarders (LCVRs) in the transmission mode. The studied properties are those involved in the operation of the LCVRs and, generally, are the most significant for optical applications: retardance, diattenuation, optical axes position, and output depolarization effects. The correct characterization of these polarization properties can be useful to improve results or estimate errors in applications using these devices. The results obtained show good accuracy and good agreement with the expected results.
We present a method for using liquid-crystal variable retarders (LCVR’s) with continually varying voltage to measure the Stokes vector of a light beam. The LCVR's are usually employed with fixed retardance values due to the nonlinear voltage-retardance behavior that they show. The nonlinear voltage-retardance relationship is first measured and then a linear fit of the known retardance terms to the detected signal is performed. We use known waveplates (half-wave and quarter-wave) as devices to provide controlled polarization states to the Stokes polarimeter and we use the measured Stokes parameters as functions of the orientation of the axes of the waveplates as an indication of the quality of the polarimeter. Results are compared to a Fourier analysis method that does not take into account the nonlinear voltage-retardance relationship and also to a Fourier analysis method that uses experimental voltage values to give a linear retardance function with time. Also, we present results of simulations for comparison.
Numerical results for scattering of electromagnetic waves from a rough surface are presented and compared with experimental results. The method uses the Kirchhoff or physical optics approximation to separate the single and double scatter terms in the total scatter pattern. It is shown that enhanced backscatter occurs in the double scatter term as predicted by a simple ray picture of the scattering process.