Yavuz Ozturk

Yavuz Ozturk

Auto-generated profile, based on publicly available information

Yavuz Ozturk

Department of Engineering, University of Cambridge, Cambridge, U.K.

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 March 2021 in IEEE Transactions on Applied Superconductivity
Verified
Journal Article
Closed access
YOYavuz Ozturk
Yavuz Ozturk
Boyang ShenBoyang Shen
Boyang Shen
RWRichard Williams
Richard Williams
JGJames Gawith
James Gawith
JYJiabin Yang
Jiabin Yang
TCTim Coombs
Tim Coombs
Magnetic Resonance Imaging (MRI) is an indispensable tool in monitoring lipid-rich tissues and the musculoskeletal system. It however requires maintaining a huge homogeneous (1 to 7 T) field. That is where superconductors come into play since they are the only feasible way to create such fields. The state-of-the-art technology utilizes low critical temperature superconductors (LTS) which require cooling down to liquid helium temperatures (4.2K). The new generation superconductors, aka the high critical temperature superconductors (HTS), can operate up to relatively elevated temperatures (technically above 100K's). In addition to that, they can withstand larger magnetic field strengths which can theoretically go up to the order of hundred Teslas in magnitude. It is evident that LTS wires of current MRI magnet technology is at their limits and new pursuits such as reaching higher fields and reducing operational/maintenance costs are in the favor of HTS tapes. There is, in fact, another advantage beyond minimization of the cryogenic costs, namely the compactness of the overall system. Utilizing certain auxiliary techniques such as flux pumping and conductive cooling of the tapes, MRI magnets can be reduced in size substantially. That, in turn, enables constructing much smaller thus mobile MRI scanners which can be brought to patients' doorsteps. Here we present the current status of our project aiming to build an HTS MRI machine dedicated to use as a mobile head scanner.

18 January 2022 in IEEE Transactions on Applied Superconductivity
Verified
Journal Article
Closed access
JHJintao Hu
Jintao Hu
JMJ. Ma
J. Ma
ASAdil Shah
Adil Shah
LHLuning Hao
Luning Hao
JYJ. Yang
J. Yang
TCTim Coombs
Tim Coombs
Direct current carrying Type II superconductors present a dc electric field under external perpendicular AC magnetic field, commonly referred to as “dynamic resistance effect”. Two kinds of AC losses occur in this situation: dynamic loss due to the interaction between the DC current and moving fluxons, and magnetization loss due to shielding current caused by the external AC magnetic fields. In general, HTS coated conductors have one substrate layer, which can be non-magnetic (Hastelloy) or magnetic (NiW). In this paper, we present the impacts of the magnetic substrate and their strength of ferromagnetism on dynamic loss and magnetization loss by using a finite-element method model based on H -formulation. This work reveals that the magnetic substrate layer does influence the dynamic loss and magnetization loss of HTS coated conductors. The dynamic loss is reduced by the adjacent magnetic substrate in the low field region and is increase in the high field region. The magnetization loss is reduced significantly by the magnetic substrate. This work will help choose HTS coated conductors with different substrate layers in different applications.

17 February 2020 in IEEE Transactions on Applied Superconductivity
Verified
Journal Article
Closed access
Boyang ShenBoyang Shen
Boyang Shen
YOYavuz Ozturk
Yavuz Ozturk
WWWei Wu
Wei Wu
LLLi Lu
Li Lu
JSJie Sheng
Jie Sheng
TCTim Coombs
Tim Coombs
This paper presents the design of an HTS magnet for an ultra compact MRI system, potentially for the rapid and early diagnosis of brain trauma. Early diagnosis and therapy stratification can reduce the risk for critically brain ill patients with the use of near patient imaging, and can aid with precision medicine. High temperature superconductors (HTS) have the ability to carry large currents in the cryogen free contrition, which can make the MRI system even smaller and lighter. The design and Genetic Algorithm (GA) optimization were based on the FEM package COMSOL Multiphysics with the LiveLink for MATLAB, together with the GA module in the MATLAB optimization toolbox. The relatively thick HTS tape, ST-12-L from the Shanghai Superconductor Technology was chosen and that made more difficulty on optimization process. Genetic Algorithm method improved the optimization performance, and the uniformity achieved 2.36 ppm in a 10 × 10 × 10 cm DSV. Two cases of the end double-pancake were compared. Further sensitivity studies were performed on the homogeneity with its relationship to the magnet length, and the thickness of HTS tape.

25 February 2021 in IEEE Transactions on Applied Superconductivity
Verified
Journal Article
Closed access
JHJintao Hu
Jintao Hu
JMJun Ma
Jun Ma
JYJiabin Yang
Jiabin Yang
MTMengyuan Tian
Mengyuan Tian
ASAdil Shah
Adil Shah
TCTim Coombs
Tim Coombs
When a superconductor is exposed to an AC magnetic field whilst carrying a constant DC transport current, a DC electrical resistance can be observed, commonly referred to as “dynamic resistance”. This dissipative effect can play a critical role in many potential high-temperature superconducting (HTS) applications, especially for the AC-field-actuated HTS switch, which is the key component in the HTS transformer-rectifier flux pump (TRFP). The characteristics of the HTS switch determine the performance and reliability of TRFP. In this paper, we report a numerical study of a new HTS switch design made of series-connected YBCO stacks. This study aims to obtain insights into the characteristics of dynamic resistance and power loss, including their relationships with the amplitude and the frequency of the AC magnetic field. The energy conversion efficiency of the HTS switch is also investigated. This work will help design a high-performance AC-field-actuated HTS switch.

20 February 2020 in IEEE Transactions on Applied Superconductivity
Verified
Journal Article
Closed access
Li ChaoLi Chao
Li Chao
JYJiabin Yang
Jiabin Yang
Boyang ShenBoyang Shen
Boyang Shen
JMJun Ma
Jun Ma
JGJamie Gawith
Jamie Gawith
TCTim Coombs
Tim Coombs
High-T c superconducting (HTS) materials are extremely promising for high-field applications, due to their relatively high upper critical field. Flux pumps are a means of energizing closed superconducting magnets without direct electrical contact. Simulation is a good method to understand the physics of the flux pumping system. In this paper, we propose a simulation methodology for a transformer-rectifier HTS flux pump. A model is built, based on the electrical circuit. The simulation methodology opens up various opportunities for flux pump developers to design the whole superconducting magnet energizing system.

1 June 2020 in IEEE Transactions on Applied Superconductivity
Verified
Journal Article
Closed access
JMJun Ma
Jun Ma
TCTim Coombs
Tim Coombs
JGJianzhao Geng
Jianzhao Geng
WCWankan Chan
Wankan Chan
JGJamie Gawith
Jamie Gawith
JHJintao Hu
Jintao Hu
When a type-II high Tc superconductor carrying a direct current is subjected to a perpendicular AC magnetic field, a direct current voltage will appear. This phenomenon is called dynamic resistance effect. In general, the high temperature superconducting (HTS) coated conductor (CC) has two stabilizer layers. However, the impacts of two stabilizer layers on the dynamic resistance, DC electrical field, losses, and temperature rise haven't been studied yet. This paper presents the impacts of the stabilizer layers and their resistivity on the dynamic resistance effect and HTS CC tape's thermal-electromagnetic behaviors by using a temperature dependent FEM model. This work reveals that the stabilizer impacts significantly on the dynamic resistance, dc voltage, power loss, and temperature rise. It is will help design high-performance AC magnetic field-controlled PCS and switches based HTS devices.