12 August 2004 in Analytical Chemistry
26 September 2005 in Lab on a Chip
We propose here a new method for continuous concentration and classification of particles in microfluidic devices, named hydrodynamic filtration. When a particle is flowing in a microchannel, the center position of the particle cannot be present in a certain distance from sidewalls, which is equal to the particle radius. The proposed method utilizes this fact, and is performed using a microchannel having multiple side branch channels. By withdrawing a small amount of liquid repeatedly from the main stream through the side channels, particles are concentrated and aligned onto the sidewalls. Then the concentrated and aligned particles can be collected according to size through other side channels (selection channels) in the downstream of the microchannel. Therefore, continuous introduction of a particle suspension into the microchannel enables both particle concentration and classification at the same time. In this method, the flow profile inside a precisely fabricated microchannel determines the size limit of the filtered substances. So the filtration can be performed even when the channel widths are much larger than the particle size, without the problem of channel clogging. In this study, concentrations of polymer microspheres with diameters of 1–3 µm were increased 20–50-fold, and they were collected independently according to size. In addition, selective enrichment of leukocytes from blood was successfully performed.
4 August 2001 in Langmuir
19 May 2005 in Lab on a Chip
A new method for continuous size separation and collection of particles in microfabricated devices, asymmetric pinched flow fractionation (AsPFF), has been proposed and demonstrated. This method improves the separation scheme of pinched flow fractionation (PFF), which utilizes a laminar flow profile inside a microchannel. In this study, multiple branch channels with different channel dimensions were arranged at the end of the pinched segment, so that the flow rate distributions to each branch channel were varied, and a large part of the liquid was forced to go through one branch channel (drain channel). In the proposed channel system, the flow profile inside the microchannel was asymmetrically amplified, enabling the separation of one-order smaller particles compared with PFF. After introducing the method, we examined the effect of the asymmetric amplification by controlling the outlet of the drain channel. Also, a mixture of 1.0 ∼5.0 µm particles was separated, and erythrocytes were successfully separated from blood. The results indicate that the AsPFF method could be applied to the separation of much smaller-size particles, since more precise separation can be achieved simply by changing the geometries of branch channels.
1 November 2012 in Biomaterials
1 July 2000 in Journal of Colloid and Interface Science