This paper research the issues of economic comparison of electrical energy storage systems based on the levelised cost of storage (LCOS). One of the proposed formulas for LCOS calculation was given, the parameters to be considered and the basic principles of their calculation were examined in detail. The LCOS was calculated for an electrical energy storage system, whose main function is to compensate for rapid changes in load power. LCOS sensitivity to changes in variables was analysed. The scope of potential application of the formula under consideration was specified, and the limitations preventing its wider use were indicated.
The paper proposes and describes a mathematical model of an energy storage system based on a battery energy storage system as part of an electric power system for calculating transient electromechanical processes. The reliability of the model is confirmed by full-scale experiments in an autonomous power system with an abruptly variable load. The model is intended for use in modern software systems to analyze the stability of power systems.
Test results of the main industrial prototype of energy storage system (ESS-10-1200-400) of nominal power 1200 kVA, energy capacity 400 kWh and voltage 10 kV based on lithium-ion batteries when operating in combination with gas engine generators (GEG) as a part of experimental power system with active abrupt variable load are given. Its structure, components and parameters, as well as the components and parameters of ESS are described. Tests have shown high operation capacity of the prototype tested, high efficiency of the implemented algorithms and confirmed the expediency of the use of ESS for smoothing power surges/sheddings in the GEG, thus preventing their emergency shutdown resulted from the power surge.
1 April 2020 in IOP Conference Series: Materials Science and Engineering
The article describes the approach to the selection of parameters of a hybrid electrical energy storage system (EESS) based on supercapacitors (SC) and lithium ion battery (LIB) for an autonomous power station with a diesel generator set (DGS). The calculations of transients in an autonomous power supply system with an abruptly variable load and participation of a hybrid EESS. The procedure of determining the share of participation in the energy exchange of storage subsystems based on LIB and SC is presented.
The paper gives an assessment of the adequacy and accuracy the energy storage system (ESS) mathematical model. The full-scale experiment was carried out on off-grid power system on May 24, 2019 in Novosibirsk, including a gas engine power plant with capacity of 2250 kW, abruptly variable active load of total 1200 kW and the industrial prototype ESS with a nominal power of 1200 kVA, energy capacity of 400 kW · h and voltage of 10 kV. ESS is based on lithium-ion batteries. Elaborated ESS mathematical model for transient processes calculation is outlined. This model was implemented in the DIgSILENT PowerFactory software. Proceeding from the research objectives it is possible to choose a calculation model for electromechanical or electromagnetic transient processes research. The results of full-scale tests and calculations performed using the ESS mathematical model proved their qualitative and quantitative coincidence sufficient for scientific and engineering studies of ESS operation in electric power industry.