Desale Tewelde Kahsay

Desale Tewelde Kahsay

Auto-generated profile, based on publicly available information

Desale Tewelde Kahsay

Desale Tewelde Kahsay, MSc, Department of Anaesthesiology and Intensive Care, Faculty of Medicine, University of Turku, Turku, Finland

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
21 November 2019 in BMC Nursing
Verified
Journal Article
Open access
PDF file
DKDesale Tewelde Kahsay
Desale Tewelde Kahsay
MPMarianne Pitkäjärvi
Marianne Pitkäjärvi
Background: Pain is a common phenomenon among emergency patients which may lead to chronic pain conditions and alteration of physiological function. However, it is widely reported that proper pain assessment and management, which is often accomplished by adequately trained nurses reduce the suffering of patients. Therefore, the aim of this study was to assess the emergency nurses´ knowledge, attitude and perceived barriers regarding pain management. Methods: A cross-sectional quantitative study design was applied to determine the nurses´ knowledge level, attitude and the perceived barriers related to pain management. Hundred twenty-six nurses from the emergency departments of seven referral hospitals of Eritrea participated in the study. Data were collected in August and September 2017. Both descriptive and inferential statistics were used to summarize and elaborate on the results. Result: In general, the knowledge level and attitude of the emergency nurses was poor. The participants’ correct mean score was 49.5%. Nurses with Bachelor’s Degree had significantly higher knowledge and attitude level compared to the nurses at the Diploma and Certificate level of professional preparation (95% CI = 7.1–16.7 and 9.4–19.1; p < 0.001) respectively. Similarly, nurses who had previous training regarding pain scored significantly higher knowledge level compared to those without training (95% CI =1.82–8.99; p = 0.003). The highest perceived barriers to adequate pain management in emergency departments were measured to be overcrowding of the emergency department (2.57 ± 1.25), lack of protocols for pain assessment (2.45 ± 1.52), nursing workload (2.44 ± 1.29) and lack of pain assessment tools (2.43 ± 1.43). There was no significant difference in perceived barriers among nurses with different demographic characteristics. Conclusion: The emergency nurses’ knowledge and attitude regarding pain management were poor. Nurses with higher educational level and nurses with previous training scored significantly higher knowledge level. This indicates the need for nursing schools and the ministry of health to work together to educate nurses to a higher level of preparation for pain assessment and management.

3 July 2017 in Southern African Journal of Anaesthesia and Analgesia
Verified
Journal Article
Open access
DKDesale Tewelde Kahsay
Desale Tewelde Kahsay
WEWaltraud Elsholz
Waltraud Elsholz
HBHabteselassie Zerezghi Bahta
Habteselassie Zerezghi Bahta
Background: The primary objective of this study was to assess whether transversus abdominis plane (TAP) block is effective as part of multimodal pain management following Caesarean section in an area with limited resources. The study also looked at the advantage of this block in reducing the consumption of morphine and diclofenac postoperatively. Methods: After approval by the institutional ethics committee and informed consent of participants, 108 ASA I and II patients for Caesarean section under spinal anaesthesia were randomly allocated to either the TAP block group or the control. The TAP block group received a landmark-orientated, bilateral TAP block in the triangle of Petit. Postoperative pain treatment followed the same protocol for both groups. Visual analogue scale (VAS) pain scores were measured at 2, 4, 6, 8, 12, 18 and 24 h postoperatively. At the same time, consumption of diclofenac and morphine was measured and compared. Results: No adverse effects of the TAP block were detected. VAS pain scores were significantly lower in the TAP block group at rest, deep breathing, intentional coughing, and mobilisation in all cases (p < 0. 05). Morphine and diclofenac consumption was significantly higher in the control group (p < 0. 001). Conclusion: TAP block reduced the VAS pain scores significantly both at rest and during stressors. As a result, morphine and diclofenac consumption was significantly reduced in the TAP block group. Therefore, it is feasible to implement TAP block as part of a multimodal analgesia regimen after Caesarean section in a tertiary health care centre in a developing nation.

2 February 2024 in IEEE Access
Verified
Journal Article
Open access
SGSofía Guridi
Sofía Guridi
MHMauranen Henry
Mauranen Henry
PEPouta Emmi
Pouta Emmi
GSGuna Semjonova
Guna Semjonova
DKDesale Tewelde Kahsay
Desale Tewelde Kahsay
XYXiao Yu
Xiao Yu
Correctly performed Cardiopulmonary Resuscitation (CPR) is a critical element in preventing deaths caused by cardiac arrest (CA). To improve the outcomes and quality of CPR, stand-alone devices that monitor the performance and provide feedback have been developed. However, these devices have multiple limitations due to their rigidity and stiffness. Furthermore, most of the devices do not account for complete chest recoil as a metric of quality CPR, reducing the quality of compressions. To overcome these limitations, this study proposes smart gloves equipped with e-textiles-based pressure sensors and inertial measurement units (IMUs) to monitor the quality adult CPR in real-time. The prototype development combined data-driven design and Research Through Design (RtD) methods, taking into account not only the accuracy but also the usability of the smart gloves. A preliminary study with nine participants performing CPR on a doll was conducted to evaluate the accuracy and wearability of the smart gloves. Study results show that the smart gloves accurately detect chest compression parameters, including compression depth, compression rate, chest recoil and interruption between compressions based on the intelligent fusion of pressure sensors and IMUs. In addition, the newly developed smart gloves are lightweight, hand adaptable, and easily replicable as an alternative for hard case devices. The design methods used in this study can be applied to design other accessible and comfortable wearable devices in healthcare settings.

3 April 2025 in Journal of Cardiovascular Nursing
Verified
Journal Article
Open access
DKDesale Tewelde Msc Kahsay
Desale Tewelde Msc Kahsay
MTMiretta Tommila
Miretta Tommila
LPLaura-Maria Peltonen
Laura-Maria Peltonen
ELEliisa Msc Löyttyniemi
Eliisa Msc Löyttyniemi
YXYu Dsc Xiao
Yu Dsc Xiao
SSSanna Salanterä
Sanna Salanterä
Background: Several audiovisual feedback (AVF) devices have been developed to monitor chest compression quality during cardiopulmonary resuscitation (CPR). However, most marketed stand-alone AVF devices are inflexible and rigid, causing discomfort and sometimes pain to the rescuers' hands. Objective: The objective of this study was to evaluate the effectiveness and usability of a newly developed soft and flexible resuscitation glove designed to improve the quality of chest compressions during CPR. Methods: We conducted a manikin-based randomized crossover study to compare the effectiveness of a newly developed AVF device (ResuGlove CPR Group) and standard CPR (Standard CPR Group) in improving the quality of chest compressions in simulated cardiac arrest cases. The usability of the newly developed ResuGlove was assessed using a System Usability Scale questionnaire. Results: There were no significant differences in compression depth (mean, 53.69 vs 53.28; P = .70) and compression rate (mean, 111.48 vs 113.38; P = .23) between the ResuGlove CPR and Standard CPR groups. However, the group using ResuGlove had a higher percentage of complete chest releases between compressions ( P = .008). Furthermore, the ResuGlove CPR Group had a significantly higher percentage of participants who performed chest compressions with adequate compression depth (82.8% vs 41.4%, P = .001) and compression rate (96.6% vs 72.4%, P = .012) compared with the Standard CPR Group. The ResuGlove usability score was calculated to be 70.4. Conclusions: The newly developed ResuGlove significantly improved the quality of certain chest compression parameters, and the device’s usability score was within the acceptable range.

1 January 2025 in SAGE Open Nursing
Verified
Journal Article
Open access
TOTecleab Okubai
Tecleab Okubai
DKDesale Tewelde Kahsay
Desale Tewelde Kahsay
TNTesfit Brhane Netsereab
Tesfit Brhane Netsereab
MAMelat Adugna Asnake
Melat Adugna Asnake
Introduction: Home blood pressure monitoring is often considered less reliable than conventional blood pressure monitoring due to different factors. Aim: To investigate variations in home blood pressure monitoring and associated factors, differences in measured blood pressure under varying conditions such as postural changes from sitting to standing, among adults with hypertension. Methods: A systematic review of studies was conducted on adults (≥18 years) with hypertension. Peer-reviewed studies published between 1992 and 2025 were searched in the Web of Science, PubMed, MEDLINE, and CINAHL databases in August 2023 and September 2025. The review included studies on home blood pressure monitoring, the associated factors, and reported in systolic and/or diastolic values. The main outcome was variations in home blood pressure monitoring categorized as small (15 mmHg). Associated factors were also identified and the findings were analyzed using narrative synthesis. Results: A total of 2,843 peer-reviewed articles were identified across four databases, of which 33 met the inclusion criteria. Generally, variations in home blood pressure monitoring ranged from −21.8 to +9.5 mmHg for systolic blood pressure and from −5.0 to +5.5 mmHg for diastolic blood pressure, where the + and − signs indicate the direction of changes. Fifteen factors associated with variations in home blood pressure monitoring were identified and broadly categorized into patient, device, procedural, protocol, and observer factors with related subcategories. Conclusions: There were variations in home blood pressure monitoring and were associated with the factors, ranging from large decreases to large increases in both systolic and diastolic blood pressures, among adults with hypertension. Therefore, when measuring and interpreting blood pressure at home, it is essential to consider the factors associated with the variations. Furthermore, this study serves as a baseline for future research. This review is registered in PROSPERO.