5 September 2022 in Case Studies in Thermal Engineering
2 August 2022 in IEEE Transactions on Industry Applications
LED lighting still suffers from its thermal problem linked mainly to the increase in junction temperature. The situation becomes more and more aggravated when it comes to decorative lighting. Indeed, this type of lighting application sometimes requires that the heat sink of the LED lamp be integrated into a narrow space, such as false or sloped ceilings, which limits the transfer of heat to the outside. In this context, the current study reports a numerical analysis of natural convection heat transfer around rectangular heat sink for LEDs lighting applications. The radiator is put in an inclined cavity with an orientation angle varying from 0̊ to 60̊. The effects of the enclosure inclination and its length on thermal behavior, flow structure in the cavity as well as on optical properties of the light source were highlighted. The CFD simulation showed a significant effect on the heat transfer rate when varying the cavity length (presented as an aspect ratio A) and its orientation. A = 4 was determined as an optimal cavity aspect ratio, and it was found that higher orientations are more sensitive to the increase of the length of the cavity. For θ = 60̊, the luminous efficiency is ameliorated by about 10% when increasing the cavity length from one to four. Accordingly, we proposed correlations in simple form to predict the heat transfer rate for different configurations studied.
17 August 2022 in Advances in Mechanical Engineering
The current study reports a numerical analysis of a two-dimensional steady-state natural convection heat transfer from grooved heated cylinder for laminar flow regime. Two groove shapes are investigated in this work: circular and triangular groove. Simulations were carried out by varying the groove location, radius ratio f from 0.1 to 1, and the Rayleigh number over the range [103–106]. The thermal and dynamic behaviors are carefully analyzed and compared to the case of non-grooved cylinder (model 0). It is found that the heat transfer rate rises up with the increase of Rayleigh number. In addition, the groove locations φ = −90, and 80° provide the lowest heat transfer rate. A decrease of 9.4% in the heat transfer rate is detected for the case of triangular groove with f = 0.7 and Ra = 105. On the other hand, the highest heat transfer rate is provided at a position φ = −45° and 45° for f > 0.65. For these last groove locations, lower f present optimal configurations to accumulate heat on the cylinder. In fact, circular grooved cylinder with f = 0.1 decreases the heat loss by 9.3% and 12.4% for the locations φ = −45° and 45°, respectively compared to model 0. These results would be useful for engineering applications that are interested in the accumulation or transfer of heat through cylindrical ducts.
10 August 2021 in Advances in Mechanical Engineering
This paper deals with a numerical study of mixed convection heat transfer in horizontal eccentric annulus. The inner cylinder is supposed hot and rotating, however the outer one is kept cold and motionless. The numerical problem was solved using COMSOL Multiphysics® which is based on finite element method. The resolution of the partial differential equations was conducted through an implicit scheme with the use of the damped Newton’s method. The present numerical analysis concerns the effect of eccentricity, rotation speed and Rayleigh number on the flow patterns, heat transfer rate, and energy efficiency of the process. It was found that the heat transfer rate increases with the increase of Rayleigh number. In addition, the heat transfer rate drops with the increase of rotation speed. Finally, we have demonstrated that maximum energy efficiency is achieved not only with higher Rayleigh number but also it is maximum with small eccentricity.
27 August 2024 in Advances in Mechanical Engineering
This paper presents a comprehensive numerical study of a truncated conical precipitator. The main objective was to enhance the efficiency of the precipitator by exploring the influence of several parameters on particle trajectories and the evolution of the collection efficiency. The studied parameters include the cone coefficient ( D), flow velocity, applied voltage, conduit diameter and length, as well as relative permeability. For each parameter, analyses were conducted on the evolution of the collection efficiency for particles with various diameters, ranging from 0.01 to 10 μm. The results obtained from the numerical simulation on COMSOL Multiphysics® indicate that, regardless of the value of D, the precipitator exhibits optimal efficiency in collecting particles with extreme diameters (0.01 and 10 μm) due to the dominance of the electrical force. In contrast, particles with intermediate diameters (0.1–1 μm) present a challenge, as the drag and electric forces are too weak to ensure effective particle collection. The study highlights that a sharper tip at the top of the precipitator significantly enhances its efficiency. Increasing the applied voltage and selecting lower inner radii of the collecting electrode reinforce the electrical force and enhance particle collection. Furthermore, increasing the height of the precipitator directs particle trajectories more effectively toward the collecting electrode. The results provide valuable insights for the design of more efficient precipitators and propose practical guidelines for improving their effectiveness. These contributions are particularly important for air pollution control technologies, offering significant advancements in this field.