1 March 2019 in Resuscitation
Optimization of automated external defibrillator (AED) placement and accessibility are warranted. We examined the associations between AED accessibility, at the time of an out-of-hospital cardiac arrest (OHCA), bystander defibrillation, and 30-day survival, as well as AED coverage according to AED locations. In this registry-based study we identified all OHCAs registered by mobile emergency care units in Copenhagen, Denmark (2008-2016). Information regarding registered AEDs (2007-2016) was retrieved from the nationwide Danish AED Network. We calculated AED coverage (AEDs located ≤200 m route distance from an OHCA) and, according to AED accessibility, the likelihoods of bystander defibrillation and 30-day survival. Of 2500 OHCAs, 22.6% (n = 566) were covered by a registered AED. At the time of OHCA, 50%, due to limited AED accessibility. The chance of a bystander defibrillation was tripled, and 30-day survival nearly doubled, when the nearest AED was accessible, compared to inaccessible, at the time of OHCA, underscoring the importance of unhindered AED accessibility.
1 September 2014 in Resuscitation
CTChristian Torp-Pedersen
+8
1 October 2018 in Resuscitation
CTChristian Torp-Pedersen
Mathematical optimization of automated external defibrillator (AED) placements has the potential to improve out-of-hospital cardiac arrest (OHCA) coverage and reverse the negative effects of limited AED accessibility. However, the generalizability of optimization approaches has not yet been investigated. Our goal is to examine the performance and generalizability of a spatiotemporal AED placement optimization methodology, initially developed for Toronto, Canada, to the new study setting of Copenhagen, Denmark. We identified all public OHCAs (1994-2016) and all registered AEDs (2016) in Copenhagen, Denmark. We calculated the coverage loss associated with limited temporal accessibility of registered AEDs, and used a spatiotemporal optimization model to quantify the potential coverage gain of optimized AED deployment. Coverage gain of spatiotemporal deployment over a spatial-only solution was quantified through 10-fold cross-validation. Statistical testing was performed using χ2 and McNemar's tests. We found 2149 public OHCAs and 1573 registered AED locations. Coverage loss was found to be 24.4% (1104 OHCAs covered under assumed 24/7 coverage, and 835 OHCAs under actual coverage). The coverage gain from using the spatiotemporal model over a spatial-only approach was 15.3%. Temporal and geographical trends in coverage gain were similar to Toronto. Without modification, a previously developed spatiotemporal AED optimization approach was applied to Copenhagen, resulting in similar OHCA coverage findings as Toronto, despite large geographic and cultural differences between the two cities. In addition to reinforcing the importance of temporal accessibility of AEDs, these similarities demonstrate the generalizability of optimization approaches to improve AED placement and accessibility.
1 March 2020 in Resuscitation
1 September 2014 in Resuscitation
12 August 2009 in European Journal of Applied Physiology