Purpose: The recent introduction of personalized alignment strategies in total knee arthroplasty (TKA) has transformed adult reconstruction. Proponents advocate for these techniques due to their kinematic benefits compared to traditional methods. Current literature supports combining medial‐pivot designs with kinematic alignment (KA) surgery. This review summarizes the application of gait analysis in KA medial‐pivot TKA and recommends gait parameters related to patient satisfaction. Methods: This review followed the Preferred Reporting Items for Systematic Reviews and Meta‐Analyses extension for Scoping Reviews (PRISMA‐ScR). One hundred twenty‐one articles from the three search engines underwent a preliminary title/abstract and full‐text screening. The final screening resulted in 23 systematic reviews (SR), meta‐analyses (M‐A) and narrative reviews (NR) as core articles of the current umbrella review. Results: Out of the original 121 SR/M‐A/NR articles, 23 (19%) were ultimately evaluated based on the reported results. Twelve articles fell into the first category (gait analysis following TKA as the main topic), five articles were designated for the second category (knee implant design), only one article was classified in the third category (kinematic alignment) and five articles were assigned to the fourth category (a combination of all main topics). Conclusions: The literature investigating the relationship between kinematic and spatiotemporal data and clinical outcomes following KA medial pivot TKA is limited. Few studies included in the current review showed that remote measurements using wearable sensors are more informative than patients' reported outcome measurements (PROMs) regarding a patient's daily level of activities and, ultimately, gait. The current review demonstrated that combining KA and MP designs can ensure a knee kinematic closer to normal than combining MA and more traditional implant designs. Level of Evidence: Level I.
Purpose: External snapping hip syndrome (ESHS) was historically attributed to isolated iliotibial band (ITB) contracture. However, the gluteus maximus complex (GMC) may also be involved. This study aimed to intraoperatively identify the ESHS origin and assess the outcomes of endoscopic treatment based on the identified aetiological type. Methods: From 2008-2014, 30 consecutive patients (34 hips) with symptomatic ESHS cases refractory to conservative treatment underwent endoscopic stepwise “fan-like” release, gradually addressing all known reasons of ESHS: from the isolated ITB, through the fascial part of the GMC until a partial release of gluteus maximus femoral attachment occurred. Snapping was assessed intra-operatively after each surgical step and prospectively recorded. Functional outcomes were assessed via the MAHORN Hip Outcome Tool (MHOT-14). Results: Twenty seven patients (31 hips) were available to follow-up at 24-56 months. In all cases, complete snapping resolution was achieved intra-operatively: in seven cases (22.6%) after isolated ITB release, in 22 cases (70.9%), after release of ITB + fascial part of the GMC, and in two cases (6.5%) after ITB + fascial GMC release + partial release of GM femoral insertion. At follow-up, there were no snapping recurrences and MHOT-14 score significantly increased from a pre-operative average of 46 to 93(p<0.001). Conclusion: Intraoperative identification and gradual addressing of all known causes of ESHS allows for maximum preservation of surrounding tissue during surgery while precisely targeting the directly involved structures. Endoscopic stepwise “fan-like” release of the ITB and GMC is an effective, tailor-made treatment option for ESHS regardless of the snapping origin in the patients with possibility to manually reproduce the snapping.
1 June 2021 in Journal of Hip Preservation Surgery
The aim of this case study is to present arthroscopic treatment of recurrent hip instability after acute post-traumatic posterior hip dislocation with a fracture of the posterior acetabular wall. A male patient aged 35 suffered a dislocation of the right hip joint with a fracture of the posterior acetabular wall due to an accident. The fracture was stabilized during emergency surgery with a locking compression plate, and the patient was released home in a hip brace. Multiple dislocations of the hip joint followed with the implant being confirmed as stable. Decision was made to qualify the patient for a right hip arthroscopy. During the surgery, ligamentum teres was reconstructed using gracilis and semitendinous muscle grafts, followed by the labrum and joint capsule repair, where the surgery that stabilized the acetabular wall fracture had damaged them. There were no complications following the procedure. Short-term follow-up of 3 months demonstrates the patient has a stable hip, reduced pain and has returned to pre-injury activities.
The aim of the study was to evaluate the potential consequences of drilling titanium alloy (Ti) and tantalum (Ta) implants. During an in vitro study, four holes were made in each of two spatially porous trabecular implants: one Ta and the other Ti alloy (Ti-6Al-7Nb). The weight and the volume of particles produced during the drilling were then measured using a Radwag XA 110/2X (USA) laboratory balance. The loss of mass of the Ti and Ta implants was respectively 1.26 g and 2.48 g, and the volume of free particles was respectively 280 mm3 and 149 mm3. The particles were recovered after each stage. Despite the use of 5 μm filters, around 0.6% of the total implant mass from both implants was not recovered after drilling (roughly 2% of the mass of the particles created). It is technically difficult to make holes in Ti and Ta implants using standard surgical tools, and the process creates a significant amount of metal particles which cannot be removed, despite intensive flushing. This may have a potentially adverse influence on the survival of the implant and result in negative systemic consequences.
15 November 2025 in American Journal of Case Reports
BACKGROUND The infection rate after revision knee arthroplasty due to previous infection is substantially higher than after revision for aseptic reasons or after primary total knee arthroplasty, ranging from 9% to 28% within several years of follow-up. Management becomes more challenging in chronic infections with soft tissue defects. The need for flap coverage is associated with higher rates of recurrent infection, reoperation, and even limb loss. Muscle flaps, particularly the gastrocnemius, play a key role in infection control and stable coverage. Radical debridement supported by methylene blue staining and early soft tissue reconstruction improve outcomes and enable future revision surgeries. CASE REPORT This case report presents an 81-year-old man with recurrent periprosthetic joint infection following total knee arthroplasty, managed successfully with a modified single-stage re-revision arthroplasty combined with soft tissue reconstruction. The procedure included radical debridement guided by methylene blue staining, prosthesis exchange, local antibiotic delivery, and coverage using bilateral gastrocnemius muscle flaps and skin grafts. The reconstruction provided durable, vascularized soft tissue coverage, enabling a safe surgical approach during a subsequent re-re-revision after 18 months. Early results are promising, although extended follow-up is required to confirm long-term success. At 12 months postoperatively, after the second re-re-revision, the patient remained pain-free, with no signs of reinfection and with preserved limb function. CONCLUSIONS A modified single-stage knee re-revision with radical bone and soft tissue debridement, aided by methylene blue staining and immediate reconstruction using gastrocnemius flaps was central to the treatment strategy This approach allows safe future revisions through well-vascularized muscle flaps.