P. Veltri

P. Veltri

Auto-generated profile, based on publicly available information

P. Veltri

Consorzio RFX, Corso Stati Uniti 4 – 35127, Padova (Italy)

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 October 2015 in Review of Scientific Instruments
Verified
Journal Article
Closed access
PDF file
PVP. Veltri
P. Veltri
VAV. Antoni
V. Antoni
PAP. Agostinetti
P. Agostinetti
MBM. Brombin
M. Brombin
KIK. Ikeda
K. Ikeda
KTK. Tsumori
K. Tsumori
At National Institute for Fusion Science (NIFS), a multi-ampere negative ion source is used to support the R&D on H− production, extraction, and acceleration. In this contribution, we study the characteristics of the acceleration system of this source, in order to characterize the beam optics at different operational conditions. A dedicated experimental campaign was carried out at NIFS, using as main diagnostic the infra-red imaging of the beam profiles. The experimental measurements are also compared with 3D numerical simulations, in order to validate the codes and to assess their degree of reliability. The simulations show a satisfactory agreement with the experimental results.

1 January 2017 in AIP Conference Proceedings
Verified
Conference Paper
Closed access
PVP. Veltri
P. Veltri
ESE. Sartori
E. Sartori
MCM. Cavenago
M. Cavenago
GSG. Serianni
G. Serianni
MBM. Barbisan
M. Barbisan
BZB. Zaniol
B. Zaniol
In the framework of the accompanying activities in support to the ITER NBI test facility, a relatively compact radiofrequency (RF) ion source, named NIO1 (Negative Ion Optimization, phase 1) was developed in Padua, Italy, in collaboration between Consorzio RFX and INFN. Negative hydrogen ions are formed in a cold, inductively coupled plasma with a 2MHz, 2.5 kW external antenna. A low electron energy is necessary to increase the survival probability of negative ions in the proximity of the extraction area. This goal is accomplished by means of a transversal magnetic field, confining the high energy electrons better than the colder electrons. In NIO1, this filter field can cover different topologies, exploiting different set of magnets and high current paths. In this contribution we study the property of the plasma in the vicinity of the extraction region for two different B field configurations. For this experiment the source was operated in pure volume conditions, in hydrogen and oxygen plasmas. The experimental data, measured by spectroscopic means, is interpreted also with the support of finite element analyses simulations of the magnetic field and a dedicated particle in cell (PIC) numerical model for the electron transport across it, including Coulomb and gas collisions.

1 February 2012 in Review of Scientific Instruments
Verified
Journal Article
Closed access
PVP. Veltri
P. Veltri
MCM. Cavenago
M. Cavenago
GSG. Serianni
G. Serianni
The propagation of a charged particle beam is accompanied by the production of secondary particles created in the interaction of the beam itself with the background gas flowing in the accelerator tube. In the drift region, where the electric field of the electrodes is negligible, secondary particles may accumulate giving a plasma which shields the self-induced potential of the charged beam. This phenomenon, known as space charge compensation is a typical issue in accelerator physics, where it is usually addressed by means of 1D radial transport codes or Monte Carlo codes. The present paper describes some theoretical studies on this phenomenon, presenting a Particle in Cell-Monte Carlo (PIC-MC) Code developed ad hoc where both radial and axial confinements of secondary particles are calculated. The features of the model, offering a new insight on the problem, are described and some results discussed.

28 December 2018
Verified
Conference Paper
Closed access
PDF file
ESE. Sartori
E. Sartori
APA. Pimazzoni
A. Pimazzoni
PVP. Veltri
P. Veltri
MCM. Cavenago
M. Cavenago
GSGianluigi Serianni
Gianluigi Serianni
In order to reduce the beam losses of the negative ion beam in the NIO1 experiment, the vacuum system was improved by installing an additional cryogenic pump. In the upgraded configuration, the negative ion beam can be operated in two regimes of high and low background pressures. The gas flow in the improved configuration was simulated, characterizing the existing pumping system and verifying the best configuration for the improved pumping scheme. The charge state of the negative ion beam moving through the background hydrogen gas is calculated, thus providing the stripping losses inside the accelerator and in the transport region. The expected values are compared with the experimental data obtained with a diagnostic beam dump, a one-dimensional carbon fiber calorimeter. The collected electric current and the heat flux reconstructed from thermal measurements are compared with the expected beam particle flux. The measurements indicate as expected an increase of negative ion current at full acceleration and a decrease of the plasma electron contribution.

21 September 2018
Verified
Conference Paper
Closed access
PDF file
ESE. Sartori
E. Sartori
HNH. Nakano
H. Nakano
PVP. Veltri
P. Veltri
MKM. Kisaki
M. Kisaki
APA. Pimazzoni
A. Pimazzoni
GSGianluigi Serianni
Gianluigi Serianni
We report on the characteristics of the beam-generated plasma in the multibeamlet case of a hydrogen negative ion beam at NIFS. The plasma potential, and the energy of secondary particles in the drift region of an ion beam, offer an insight into the mechanisms that allow beam transport in low pressure gasses. The first measurements reported here were made by means of a four-gridded retarding field energy analyzer, combined with the measurement of the drain current at the beam dump, and with infrared beamlet monitoring technique. The retarding field analyzer measures the energy distributions of particles emitted radially from the beam-generated plasma [1]. The beam is dumped onto a graphite calorimeter, which is electrically insulated, so that it can be electrically biased and the collected current can be measured. The thermal image of the calorimeter is acquired during the beam pulse, thus offering a quantitative estimation of the single beamlet optics and multibeamlet focusing. Finally, the influence of the neutral gas density is studied by puffing hydrogen gas in this drift region. The measured ion and electron energy distribution functions are strongly affected by the electric bias of the calorimeter. For a 47kV, 0.3A beam, an electron temperature of 3eV at the plasma edge was found. The energy distribution of the ions for a pressure of about 0.03Pa is presented, from which the plasma potential can be inferred.

21 September 2018
Verified
Conference Paper
Closed access
PDF file
PVP. Veltri
P. Veltri
LBL. Buonincontri
L. Buonincontri
ESE. Sartori
E. Sartori
VCV. Cervaro
V. Cervaro
MFM. Fincato
M. Fincato
GSGianluigi Serianni
Gianluigi Serianni
In view of the future experiments on the large ion sources used for the neutral beam injection system of ITER and DEMO reactor, a small scale negative ions source NIO1 (negative ion optimization, phase 1) is operated at Consorzio RFX since 2014. At this stage H− are mainly formed by volume processes, while the use of cesium vapor to enhance the surface production is foreseen in second stage. The plasma is sustained by a 2.5 kW RF generator, inductively coupled via a seven turn coil surrounding the plasma chamber using 2 MHz frequency. The production and survival of negative ions strongly depends on the plasma properties in the vicinity of the apertures from which particles are extracted and a beam is formed. In order to characterize these properties against the variable pressures, input power and magnetic field strength in the source a dedicated campaign with a movable Langmuir probe immersed in the plasma was carried out. In this paper the installation of such probe on NIO1 is described, and the data acquired in configuration of the magnetic field are then presented and discussed.