Katsuhiro Ohuchi

Katsuhiro Ohuchi

Auto-generated profile, based on publicly available information

Katsuhiro Ohuchi

Department of Clinical Engineering Juntendo University Tokyo Japan

Research Focus & Metrics

Academic Career Length

22Years (2005-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
24 June 2005 in Artificial Organs
Verified
Journal Article
Closed access
PDF file
HHHideo Hoshi
Hideo Hoshi
Junichi AsamaJunichi Asama
Junichi Asama
TSTadahiko SHINSHI
Tadahiko SHINSHI
KOKatsuhiro Ohuchi
Katsuhiro Ohuchi
MNMakoto Nakamura
Makoto Nakamura
STSetsuo Takatani
Setsuo Takatani

12 December 2017 in Biomedical Optics Express
Verified
Journal Article
Open access
PDF file
DSDaisuke Sakota
Daisuke Sakota
TFTatsuki Fujiwara
Tatsuki Fujiwara
KOKatsuhiro Ohuchi
Katsuhiro Ohuchi
KKKatsuyuki Kuwana
Katsuyuki Kuwana
HYHiroyuki Yamazaki
Hiroyuki Yamazaki
OMOsamu Maruyama
Osamu Maruyama
We developed an optical thrombus sensor for a monopivot extracorporeal centrifugal blood pump. In this study, we investigated its quantitative performance for thrombus detection in acute animal experiments of left ventricular assist using the pump on pathogen-free pigs. Optical fibers were set in the driver unit of the pump. The incident light at the near-infrared wavelength of 810 nm was aimed at the pivot bearing, and the resulting scattered light was guided to the optical fibers. The detected signal was analyzed to obtain the thrombus formation level. As a result, real-time and quantitative monitoring of the thrombus surface area on the pivot bearing was achieved with an accuracy of 3.6 ± 2.3 mm2. In addition, the sensing method using the near-infrared light was not influenced by changes in the oxygen saturation and the hematocrit. It is expected that the developed sensor will be useful for optimal anticoagulation management for long-term extracorporeal circulation therapies.

9 March 2022 in Artificial Organs
Verified
Journal Article
Open access
RKRyo Kosaka
Ryo Kosaka
DSDaisuke Sakota
Daisuke Sakota
HNHiromichi Niikawa
Hiromichi Niikawa
KOKatsuhiro Ohuchi
Katsuhiro Ohuchi
HAHirokuni Arai
Hirokuni Arai
TOToshihiro Okamoto
Toshihiro Okamoto
Background: Thermography is a noninvasive technology to detect low temperatures in poorly circulated areas. In ex vivo lung perfusion (EVLP), lungs are rewarmed to body temperature during the initial 1 h. Currently, the effect of graft thermal changes during the rewarming phase on pulmonary function is unknown. In this study, we evaluated the correlation of lung surface temperature with physiological parameters, wet/dry ratio, and transplant suitability in Lund‐type EVLP.Methods: Fifteen pigs were divided into three groups: control group (no warm ischemia) or donation after circulatory death groups with 60 or 90 min of warm ischemia (n = 5, each). Thermal images of the lower lobes were continuously collected from the bottom of an organ chamber using infrared thermography throughout EVLP.Results: At 8 min, lung surface temperatures of nonsuitable cases were significantly lower than in suitable cases (25.1 ± 0.6 vs. 27.8 ± 1.2°C, p < 0.001), while there was no difference in lung surface temperatures between the two groups at 0–4 min and 12–120 min. There was a significant negative correlation between lung surface temperatures at 8 min and wet/dry ratio at 2 h in the lower lobes (R = −0.769, p < 0.001, cutoff = 26°C, area under the curve = 1.0). A lung surface temperature of <26°C was significantly correlated with poor pulmonary function and transplant nonsuitability.Conclusion: A lung surface temperature of ≥26°C at 8 min is a good early predictor of transplant suitability in cellular EVLP and might be applicable in clinical EVLP.

30 June 2007
Verified
Book Chapter
Closed access
PDF file
RSRyohei Saisho
Ryohei Saisho
TOTakuya Ohsugi
Takuya Ohsugi
MWMasaya Watada
Masaya Watada
YKYong-Jae Kim
Yong-Jae Kim
KOKatsuhiro Ohuchi
Katsuhiro Ohuchi
YUYong-Su Um
Yong-Su Um

27 June 2025 in Artificial Organs
Verified
Journal Article
Open access
HSHironobu Sakurai
Hironobu Sakurai
TFTatsuki Fujiwara
Tatsuki Fujiwara
KOKatsuhiro Ohuchi
Katsuhiro Ohuchi
WHWataru Hijikata
Wataru Hijikata
DTDaiki Toda
Daiki Toda
TFTomoyuki Fujita
Tomoyuki Fujita
Background: Extracorporeal membrane oxygenation (ECMO) provides mechanical circulatory and respiratory support. However, thrombus formation in the circuit can lead to hemorrhagic complications, requiring improvements in ECMO anti‐thrombogenicity. Few studies have reported the effect of pulsatile flow on thrombus formation in ECMO circuits. This study evaluated how pulsatile flow affects thrombus formation inside the membrane oxygenator. Methods: This study was conducted in pigs ( n = 5) using an experimental model in which each pig was connected to two different ECMO circuits: one with steady flow (via the jugular vein and carotid artery) and the other with pulsatile flow (via the femoral vein and artery). The pulsatile waveform was generated as an upward sinusoidal waveform added to the baseline frequency. Both circuits were set to a mean flow rate of 2 L/min and operated for 4 h without anticoagulation. Thrombus formation in the membrane oxygenators was observed during and after circulation. The thrombus area was quantified using image analysis. Results: All experiments were completed with stable hemodynamics. The pressure in the pulsatile circuit was confirmed to be a pulsatile waveform. The thrombus area in the steady flow circuits was 81.5%, 10.6%, 42.1%, 60.2%, and 96.7%, while those in the pulsatile flow circuits were 6.2%, 5.2%, 8.4%, 9.9%, and 65.8%, respectively. The thrombus area in the pulsatile flow circuit tended to be smaller than that in the steady flow circuit. Conclusions: Pulsatile flow with a specific waveform may reduce thrombus formation in membrane oxygenators, potentially enhancing the anti‐thrombogenicity of ECMO circuits.