8 October 2025 in Science Translational Medicine
Upon injury to the mammalian peripheral nervous system (PNS), severed axons undergo rapid SARM1-dependent programmed axon death (Wallerian degeneration), but a potential role for Sarm1 in PNS regeneration remains unclear. We show that in mouse dorsal root ganglia with their axons cut, Sarm1 delayed the activation of injury-induced transcriptional programs associated with axon outgrowth and immune function. After sciatic nerve crush in
Sarm1
−/−
mice, axons rapidly extended through the nerve injury site, but growth stalled more distally. Slow axon regeneration in the distal nerve was accompanied by delayed induction of the nerve repair response by Schwann cells and delayed clearance of disintegrating myelin. Nerve fibers did regenerate in
Sarm1
−/−
mice, but regeneration was delayed, and axons exhibited reduced caliber and aberrant target innervation. Tibial nerve action potentials were weaker, and recovery of hind paw function was delayed but ultimately not impaired. Grafting of mouse
Sarm1
−/−
nerves into wild-type mice and mouse wild-type nerves into
Sarm1
−/−
mice revealed that the
Sarm1
−/−
nerve microenvironment was hostile to wild-type axon regeneration and, conversely, that
Sarm1
−/−
axons robustly grew into mouse wild-type nerve grafts. Ex vivo, the appearance of c-Jun–labeled Schwann cells in cultured mouse
Sarm1
−/−
nerves was delayed but could be accelerated by pharmacological inhibition of ErbB kinase. Our study highlights the opposing functions of Sarm1 deficiency in dorsal root ganglia and distal nerves in mice, the consequence of which is delayed PNS regeneration.
12 August 2024 in bioRxiv
Brain-machine interface (BMI) controlled functional electrical stimulation (FES) is a promising treatment to restore hand movements to people with cervical spinal cord injury. Recent intracortical BMIs have shown unprecedented successes in decoding user intentions, however the hand movements restored by FES have largely been limited to predetermined grasps. Restoring dexterous hand movements will require continuous control of many biomechanically linked degrees-of-freedom in the hand, such as wrist and finger flexion, that would form the basis of those movements. Here we investigate the ability to restore simultaneous wrist and finger flexion, which would enable grasping with a controlled hand posture and assist in manipulating objects once grasped. We demonstrate that intramuscular FES can enable monkeys with temporarily paralyzed hands to move their fingers and wrist across a functional range of motion, spanning an average 88.6 degrees at the metacarpophalangeal joint flexion and 71.3 degrees of wrist flexion, and intramuscular FES can control both joints simultaneously in a real-time task. Additionally, we demonstrate a monkey using an intracortical BMI to control the wrist and finger flexion in a virtual hand, both before and after the hand is temporarily paralyzed, even achieving success rates and acquisition times equivalent to able-bodied control with BMI control after temporary paralysis in two sessions. Together, this outlines a method using an artificial brain-to-body interface that could restore continuous wrist and finger movements after spinal cord injury. One Sentence Summary We show in non-human primates that intramuscular functional electrical stimulation can flex the wrist and fingers through a functional range of movement, can be controlled precisely, and that a brain-machine interface can determine command signals for intended finger and wrist flexion.
12 November 2026 in bioRxiv
Objective. Neural decoders for dexterous finger movements are limited by the accuracy with which ground truth movement is measured. In non-human primates (NHPs), hand kinematics are typically recorded with instrumentation that constrains movement dimensionality. We evaluated whether a markerless camera system could replace conventional methods for tracking movements in real time. Approach. We developed Freebie, a real-time markerless system for tracking NHP finger movements. Keypoints detected online were used in place of manipulandum bend sensor signals. Two NHPs performed tasks by flexing fingers to move a virtual hand into target zones. The virtual hand was directly controlled using bend sensors or Freebie-derived kinematics, or indirectly controlled through a Kalman filter (KF) decoding kinematics from forearm electromyographic (EMG) activity. We quantified Freebie's accuracy relative to manual labels, agreement with bend sensor measurements, and latencies. We assessed online performance under Freebie control and compared EMG KFs trained using Freebie-derived labels with those trained using bend-sensor-derived labels. Main Results. We observed a median end-to-end latency of 15.8 ms at a 30 FPS camera acquisition rate, and 16.2 ms at 60 FPS. Freebie labels closely tracked bend sensor positions (median |r|=0.96). Median keypoint errors were 1.7 to 6.5 pixels, below the 20-pixel width of the smallest tracked finger. Direct Freebie control did not differ from bend sensor control on five of six online metrics; path efficiency was higher with Freebie. EMG KFs trained on Freebie-derived labels performed similarly to those trained on bend sensor labels online. When evaluated offline, models trained with Freebie had lower error. Significance. These findings indicate that bend sensors are not required to obtain finger labels for training a decoder: markerless keypoints alone provided effective labels. This is an important first step towards real-time tracking of more complex movements, beyond what could be easily measured with a manipulandum.