Yan Li

Yan Li

Auto-generated profile, based on publicly available information

Yan Li

Casey Eye Institute, Oregon Health and Science University, Portland, Oregon, USA

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 December 2012 in Ophthalmology
Verified
Journal Article
Closed access
YLYan Li
Yan Li
OTOu Tan
Ou Tan
RBRobert Brass
Robert Brass
JWJack L. Weiss
Jack L. Weiss
DHDavid Huang
David Huang

1 February 2016 in Journal of Cataract & Refractive Surgery
Verified
Journal Article
Closed access
YLYan Li
Yan Li
WCWinston Chamberlain
Winston Chamberlain
OTOu Tan
Ou Tan
RBRobert Brass
Robert Brass
JWJack L. Weiss
Jack L. Weiss
DHDavid Huang
David Huang
To screen for subclinical keratoconus by analyzing corneal, epithelial, and stromal thickness map patterns with Fourier-domain optical coherence tomography (OCT). Four centers in the United States. Cross-sectional observational study. Eyes of normal subjects, subclinical keratoconus eyes, and the topographically normal eye of a unilateral keratoconus patient were studied. Corneas were scanned using a 26,000 Hz Fourier-domain OCT system (RTVue). Normal subjects were divided into training and evaluation groups. Corneal, epithelial, and stromal thickness maps and derived diagnostic indices, including pattern standard deviation (PSD) variables and pachymetric map-based keratoconus risk scores, were calculated from the OCT data. Area under the receiver operating characteristic curve (AUC) analysis was used to evaluate the diagnostic accuracy of the indices. The study comprised 150 eyes of 83 normal subjects, 50 subclinical keratoconus eyes of 32 patients, and 1 topographically normal eye of a unilateral keratoconus patient. Subclinical keratoconus was characterized by inferotemporal thinning of the cornea, epithelium, and stroma. The PSD values for corneal (P < .001), epithelial (P < .001), and stromal (P = .049) thickness maps were all significantly higher in subclinical keratoconic eyes than in the normal group. The diagnostic accuracy was significantly higher for PSD variables (pachymetric PSD, AUC = 0.941; epithelial PSD, AUC = 0.985; stromal PSD, AUC = 0.924) than for the pachymetric map-based keratoconus risk score (AUC = 0.735). High-resolution Fourier-domain OCT could map corneal, epithelial, and stromal thicknesses. Corneal and sublayer thickness changes in subclinical keratoconus could be detected with high accuracy using PSD variables. These new diagnostic variables might be useful in the detection of early keratoconus. Oregon Health and Science University (OHSU) and Drs. Li, Tan, and Huang have a significant financial interest in Optovue, Inc. These potential conflicts have been reviewed and managed by OHSU. Dr. Brass receives research grants from Optovue, Inc. Drs. Chamberlain and Weiss have no financial or proprietary interest in any material or method mentioned.

1 June 2021 in Journal of Cataract & Refractive Surgery
Verified
Journal Article
Closed access
YYYuli Yang
Yuli Yang
EPElias Pavlatos
Elias Pavlatos
WCWinston Chamberlain
Winston Chamberlain
DHDavid Huang
David Huang
YLYan Li
Yan Li
Purpose: To detect keratoconus using optical coherence tomography (OCT) corneal map parameters and patterns. Setting: Casey Eye Institute, Oregon Health and Science University, Portland, Oregon. Design: Cross-sectional observational study. Methods: A spectral-domain OCT was used to acquire corneal and epithelial thickness maps in normal, manifest keratoconic, subclinical keratoconic, and forme fruste keratoconic (FFK) eyes. A 2-step decision tree was designed. An eye will be classified as keratoconus if both decision tree conditions are met. First, at least 1 of the 4 quantitative corneal thickness (minimum, minimum–maximum, and superonasal–inferotemporal) and epithelial thickness (standard deviation) map parameters exceed cutoff values. Second, presence of both concentric thinning pattern on the epithelial thickness map and coincident thinning patterns on corneal and epithelial thickness maps by visual inspection. Results: The study comprised 54 eyes from 29 normal participants, 91 manifest keratoconic eyes from 65 patients, 12 subclinical keratoconic eyes from 11 patients, and 19 FFK eyes from 19 patients. The decision tree correctly classified all normal eyes (100% specificity) and had good sensitivities for detecting manifest keratoconus (97.8%), subclinical keratoconus (100.0%), and FFK (73.7%). Conclusions: The 2-step decision tree provided a useful tool to detect keratoconus, including cases at early disease stages (subclinical keratoconus and FFK). OCT corneal and epithelial thickness map parameters and patterns can be used in conjunction with topography to improve keratoconus screening.

3 February 2015 in Investigative Ophthalmology & Visual Science
Verified
Journal Article
Open access
PDF file
JRJennifer Rose-Nussbaumer
Jennifer Rose-Nussbaumer
YLYan Li
Yan Li
PLPhoebe Lin
Phoebe Lin
ESEric B Suhler
Eric B Suhler
MAMark Asquith
Mark Asquith
DHDavid Huang
David Huang
Purpose: The differential diagnosis of a patient presenting with anterior uveitis is broad and can present a diagnostic challenge. In this study, we evaluate the characteristic findings of inflammatory cells on optical coherence tomography (OCT) both in vitro and in vivo. Methods: Blood from two healthy volunteers was prepared using standardized methods for cell sorting with a flow cytometer (FASCAria; BD Biosciences). Neutrophils, lymphocytes, monocytes, and red blood cells were placed in suspension and scanned with a 26 kHz Fourier-domain OCT system (RTVue; Optovue, Inc.) with 5 µm axial resolution. Custom software algorithms were used to identify cells based on their reflectance distribution. These algorithms were then applied to OCT images obtained from uveitis patients with active anterior chamber inflammation. Results: On OCT images the cells appeared as hyper-reflective spots. In vitro, cell reflectance was statistically significantly different between all of the cell types (neutrophils, monocytes, lymphocytes and red blood cells P < 0.001 Mann-Whitney test). The relationship between underlying disease and cell type imaged on OCT was highly statistically significant with HLA-B27 associated uveitis patients having a predominantly polymorphonuclear pattern on OCT and sarcoidosis and inflammatory bowel disease patients having a predominantly mononuclear pattern on OCT (P < 0.001, Fisher's exact test). Conclusions: These in vitro and in vivo data demonstrate the potential of OCT to evaluate cells in the anterior chamber of patients non-invasively. OCT may be a useful adjunct to guide the diagnosis and treatment of ocular inflammatory conditions.

1 January 2012 in Journal of Ophthalmology
Verified
Journal Article
Open access
PDF file
MBMatthew Bald
Matthew Bald
YLYan Li
Yan Li
DHDavid Huang
David Huang
New advances in anterior segment optical coherence tomography (OCT) technology development allow visualizing the anterior chamber angle of the eye with high speed and high resolution. Fourier-domain (FD) OCT instruments working at 840 nm can reliably identify fine angle structures such as the Schwalbe's line. This paper demonstrates quantitative angle assessment with 840 nm FD-OCT and provides diagnostic cutoff values for occludable angle detection. This is useful for angle closure glaucoma diagnosis and management. Moreover, 840 nm FD-OCT is a useful tool for postsurgical evaluation in glaucoma patients.

1 November 2020 in Journal of Refractive Surgery
Verified
Journal Article
Closed access
PDF file
EPElias Pavlatos
Elias Pavlatos
SCShihao Chen
Shihao Chen
YYYuli Yang
Yuli Yang
QWQinmei Wang
Qinmei Wang
DHDavid Huang
David Huang
YLYan Li
Yan Li
PURPOSE: To develop a coincident thinning (CTN) index to differentiate between keratoconic and healthy corneas using optical coherence tomography (OCT) measurements of pachymetry and epithelial thickness. METHODS: Pattern deviation maps of pachymetry and epithelial thickness were generated using Fourier-domain OCT images of the cornea. The co-localized thinning of the two maps was quantified using a novel CTN index, which was calculated from Gaussian fits of the regions of maximum relative thinning. The CTN index was validated using k-fold cross-validation, and its classification performance was compared to minimum pachymetry and maximum keratometry. RESULTS: A total of 82 normal eyes and 133 eyes within three groups of keratoconus severity were evaluated. The pattern deviation maps for the keratoconic eyes showed relative thinning that was larger in magnitude and more strongly correlated with the Gaussian function compared to normal eyes (all P < .01). The distance between the pachymetric and epithelial maximum relative thinning locations was significantly smaller for the keratoconic eyes than for the normal eyes (all P < .02). The CTN index was significantly larger for all three keratoconus groups compared to normal eyes (all P < .0001). The CTN index demonstrated a sensitivity of 100% in detecting manifest keratoconus, 100% for subclinical keratoconus, and 56% for forme fruste keratoconus. The overall classification accuracy was better for the CTN index (93%) than for minimum pachymetry (86%) and maximum keratometry (86%). CONCLUSIONS: The CTN index is a highly sensitive measure of coincident pachymetric and epithelial thinning. It provides valuable information for detecting and monitoring early to moderate keratoconus. [ J Refract Surg . 2020;36(11):757–765.]