Housing retrofits are undertaken to reduce energy use and to improve ‘occupants’ indoor environmental conditions. Despite increased retrofitting of the Italian housing stock, there is a lack of data on their energy use and indoor environmental quality (IEQ). This paper fills this gap by a post-occupancy evaluation (POE) study of seven retrofitted apartments in northern Italy; a non-retrofitted case study was included as a comparison. The study aimed to understand aspects of IEQ and occupant satisfaction after energy-efficiency retrofits. A mixed-method approach encompassed occupant satisfaction surveys, energy bill comparisons, in-situ indoor air temperature, and relative humidity measurements. Results highlighted ‘occupants’ thermal comfort improvement and heating energy consumption reduction after retrofits. Furthermore, reported preferred indoor temperatures w within a broader range than the recommended Italian regulations and CIBSE guide A standard. However, some participants reported unintended consequences, including mould growth and noise from the mechanical ventilation system. This study shows the potential of POE to understand the actual performance of retrofitted residential buildings. However, the difficulties of conducting a POE in retrofitted existing residential buildings show the need of further research on how to effectively conduct POE in retrofitted residential buildings, including improved digital quality monitoring methods.
Tampere is one of the largest cities in Finland with a population of 260,000. The air quality in Tampere has been measured since 2005 at up to four different air quality stations. This study is the first analysis of the 20-year data set (2005–2024), gathered primarily for regulatory purposes. This analysis covers typical air quality metrics: PM10, PM2.5, nitrogen oxides, and ozone, as well as particle number concentration and lung-deposited surface area concentration when available. Overall, Tampere has low levels of pollution, being mostly below the WHO 2021 air quality guidelines, and most pollutant concentrations have decreased over the past 20 years. However, PM2.5 concentrations have stabilized at around ~ 5 ug/m3 since 2019, and particle number concentrations have shown a slight increase at one measurement site. Analysis of monthly trends shows elevated PM10 concentrations in springtime, caused mainly by studded tires grinding the road surface in combination with dry weather. NOx concentrations are highest during winter months, and the WHO 2021 annual guideline value (10 µg/m3) is exceeded at near-traffic measurement stations. Based on our analysis, traffic remains the most important local source of air pollution in Tampere. Graphical abstract
Airports have been identified as major sources of ultrafine particles, which have gained increasing attention due to their linkage with adverse health effects. To better understand the exposure, impacts and needed regulatory actions related to airport-originated pollution, the characteristics, dynamics and dispersion of these emissions should be known. In this study, we investigate particle pollution from a medium-large international airport (Helsinki-Vantaa, Finland) by utilising a stationary measurement site near the airport and mobile laboratory measurements up to 10 km away from the determined airport reference location. We report particle number concentration (PNC) and size distributions (1.2 nm-2.5 µm), emission factors as well as dispersion of particles larger than 2.5 nm, 4 nm, 10 nm and 23 nm, BC, PM2.5 and lung deposited surface area (LDSAal). Furthermore, data from a long-term air quality monitoring site and 12 PNC sensor sites up to 15 km away are used to investigate the long-term impacts of the airport. Finally, we estimate the airport's contribution to yearly averaged PNC and LDSAal in the surrounding areas. Overall, the studied airport is a major source of ultrafine particles: The downwind PNC> 10 nm exceeded the World Health Organization's definition for high short-term PNC (20 000 #/cm3) up to a 4.4 km distance, and 500-5 000 #/cm3 yearly increases of PNC>10 nm at 2-5 km distances were estimated. The high contribution of particles smaller than 10 nm and nanocluster aerosols (<3 nm) suggest an important role of (semi-)volatile compounds in the airport emissions.