Yinguo Huang

Yinguo Huang

Auto-generated profile, based on publicly available information

Yinguo Huang

Tianjin University

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 March 2013 in EURASIP Journal on Wireless Communications and Networking
Verified
Journal Article
Open access
PDF file
YHYin-Guo Huang
Yin-Guo Huang
XLXinghua Li
Xinghua Li
PCPei-Fen Chen
Pei-Fen Chen
Calibration is one of the most important technologies for line-structured light vision sensor. The existing calibration methods depend on special calibration equipments, whose accuracy determines the calibration accuracy. It is difficult to meet the requirements of universality and field calibration with those methods. In order to solve these problems, a new calibration method based on the combined target for line-structured light multi-vision sensor is proposed. Each line-structured light multi-vision sensor is locally calibrated by combined target with high precision. On the basis of global calibration principle and the characteristics of the combined target, global calibration and local calibration are unified. The unification avoids the precision decrement caused by coordinate transformation. And the occlusion problem of 3D reference objects can be avoided. An experimental system for 3D multi-vision measurement is set up with two sets of vision sensor and its calibration matrix is obtained. To improve the calibration accuracy, the method of acquiring calibration points with high precision and error factors in calibration are analyzed. After being calibrated, the experimental system is finally tested through a workpiece measurement experiment. The repeatability of this system is 0.04 mm, and it proves that the proposed calibration method can obtain high precision. Moreover, by changing the structure of the combined target, this calibration method can adapt to the different multi-vision sensors, while the accuracy of the combined target is still guaranteed. Thus, this calibration method has the advantages of universality and field calibration.

1 September 2020 in Nanotechnology and Precision Engineering
Verified
Journal Article
Open access
YHYinguo Huang
Yinguo Huang
SZShiyu Zhang
Shiyu Zhang
LGLe Gao
Le Gao
YZYelong Zheng
Yelong Zheng
With the wide application of laser in the field of skin plastic surgery, micro laser galvanometer scanner has made great progress in this field with its portability. However, the measurement method used to measure the deflection angle of laser galvanometer in the narrow space of scanner with high precision remains to be studied. In this paper, an angle measurement method based on magnetic field is proposed, and the effect of the shapes of permanent magnets (PMs) on the measurement is studied by theoretical and experimental study under the condition that the maximum available space for the PMs is a 10 mm side cube. An angle measuring experimental device is set up, and the contrast experiment is carried out with different PMs which are the same as simulation. The experimental results show that cylindrical PM is more suitable than other PMs, which is consistent with the simulation results, and the maximum nonlinearity error is 0.562%. This method has the advantages of small volume, non-contact measurement, small moment of inertia, good dynamic response and no external excitation for the PMs, so it has a broad application prospect in micro laser galvanometer scanner.

22 November 2022 in Optics Express
Verified
Journal Article
Closed access
YYYong Yang
Yong Yang
MZMeirong Zhao
Meirong Zhao
YZYelong Zheng
Yelong Zheng
YHYinguo Huang
Yinguo Huang
Augmented reality (AR) is desperately needed in the Metaverse. The geometrical waveguide receives increased attention in AR technology as achieving high resolution, full-color display, etc. However, the stray light and ghost image problems resulting from the parallelism errors severely deteriorate the imaging quality. According to the light propagation of the waveguide, a measuring system based on the combination of the autocollimator and the testing telescope (CAT) method was proposed to measure the parallelism errors of the partially reflective mirror array (PRMA). The results indicated that this method could measure the parallelism errors precisely with the maximum repeatability of 0.63 ′ ′ . The method could decouple the coupling of the parallelism errors of the PRMA and the substrate surfaces to imaging quality effectively. The precise parallelism measuring is expected to contribute to mass production and low cost by promoting the waveguide design and fabrication.

6 June 2018 in Instrumentation Science & Technology
Verified
Journal Article
Closed access
XZXiaomei Zhang
Xiaomei Zhang
MZMeirong Zhao
Meirong Zhao
YHYinguo Huang
Yinguo Huang
YZYelong Zheng
Yelong Zheng
With the recent developments in science and technology, torque measurements have been widely used in many fields. However, present torque measurement methods have limitations for long-term applications. Therefore, a new method of non-contact torque measurement based on the magnetomachanical effect is reported that may be used in reducing fatigue for long-term measurements. The theory of the changes in magnetization with torque are analyzed to construct a model. Hence, an experiment platform was constructed that includes an excitation coils, shaft, and Gauss meter. The relationship between the magnetic induction and the torque was measured using this apparatus. The results show that the experimental measurements are in agreement with mathematical models obtained using magnetomechanical concepts. The results also show that the maximum nonlinearity error of the system is 0.6% and the maximum repetitive error is 3.125%. Additionally, this proposed method meets the requirements for long-term torque measurements and may also be used for the non-contact characterization of the torque of watercraft and airplanes.

1 April 2018 in AIP Advances
Verified
Journal Article
Open access
PDF file
ZWZhiyi Wang
Zhiyi Wang
MZMeirong Zhao
Meirong Zhao
JJJile Jiang
Jile Jiang
LZLele Zhang
Lele Zhang
SZShuya Zhuang
Shuya Zhuang
YZYelong Zheng
Yelong Zheng
The interaction force is very important in the study of the contact process of droplets and super-hydrophobic substrates. Accurate interaction force measurement in the air has far-reaching impact on industrial production and biomimetic field. However, limited by the evaporation of small droplets, interaction force can only be measured in the liquid by AFM and other devices. A millimetric cantilever was used to make it possible to measure the interaction between droplets and super-hydrophobic substrates in the air. The optical lever was calibrated with the electrostatic force. The super- hydrophobic substrates were fabricated using nano particles and copper grids. We finally acquired the interaction force and wetting time between the droplet and super- hydrophobic substrates with different grid fractions and similar contact angle. The results showed that the interaction force decreased with the increase of the grid fraction. These would open a new way of understanding the mechanism of hydrophobic.

1 January 2024 in Journal of Applied Optics
Verified
Journal Article
Open access
PDF file
ZLZhen Li
Zhen Li
GNGe Naiyi
Ge Naiyi
ZHZhang Haitao
Zhang Haitao
ZYZheng Yelong
Zheng Yelong
ZMZhao Meirong
Zhao Meirong
天津天津大学精密测试技术及仪器国家重点实验室,天津300072
天津大学精密测试技术及仪器国家重点实验室,天津300072

浊度对于评价水体质量具有重要的意义。针对90°散射法在高浊度范围测量误差大、分辨率低的问题,提出了一种135°散射大量程浊度测量方法。由于散射相位函数与散射角密切相关,实验研究了散射角的浊度测量适应性。通过多项式拟合阶次分析发现,在100 NTU~2 000 NTU范围内单一散射条件下,135°散射法具有更大的量程范围。经过实验标定,分段线性拟合的 R^2 结果分别为0.99(100 NTU~800 NTU),0.98(800 NTU~1 500 NTU)和0.99(1 500 NTU~2 000 NTU)。实验证明,135°散射法可以扩大浊度测量范围,改善高浊度范围内测量精度。