Aaron Thomas

Aaron Thomas

Auto-generated profile, based on publicly available information

Aaron Thomas

Leeds Beckett University

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
2 June 2025 in Journal of Sports Sciences
Verified
Journal Article
Open access
JWJosh Walker
Josh Walker
ATAaron Thomas
Aaron Thomas
DLDavid Lunn
David Lunn
GNGareth Nicholson
Gareth Nicholson
CTCatherine B. Tucker
Catherine B. Tucker
We do not yet understand the concurrent validity of markerless motion capture (MMC) to measure kinematic differences between multiple gait speeds. This study determined the capacity of Theia3D (Theia Markerless Inc.) MMC to detect sagittal-plane kinematic responses to different gait speeds during walking (3 and 5 km/h) and running (10 and 12 km/h). Fourteen participants ambulated on a motorised treadmill, while marker-based motion capture, through optoelectronic cameras (Oqus 7+, Qualisys AB), and MMC, through videos (Miqus, Qualisys AB) were synchronously collected. Sagittal-plane changes in pelvis, hip, knee, and ankle kinematics were compared. Mostly excellent waveform similarity was found for joint kinematic changes (coefficient of multiple determination [CMD] ≥ 0.87), but pelvic tilt was less similar (CMD ≤0.48). Agreement between outcome measures (joint minima and maxima, range of motion) was mostly good-to-excellent (intraclass correlation coefficient [ICC] = 0.475-0.950) with standard error of measurement values of less than 1°. Pelvis kinematics showed lower agreement between systems (ICC = 0.032-0.776). In this study, Theia3D detected changes in hip, knee, and ankle sagittal-plane joint kinematics between speeds with a similar accuracy to the marker-based approach. Therefore, Theia3D is appropriate for use if interested in lower-limb sagittal joint kinematics, but not pelvic tilt.

29 April 2025 in PLOS ONE
Verified
Journal Article
Open access
PDF file
ATAaron Thomas
Aaron Thomas
DLDavid E. Lunn
David E. Lunn
JWJosh Walker
Josh Walker
Preferred walking speed (PWS) is lower when wearing a controlled ankle motion (CAM) boot, which can potentially make comparisons between footwear conditions difficult. Standardising walking speed accounts for this but lacks the ecological validity of PWS. The aim of this study was to compare acute biomechanical responses to CAM boot wear when walking is freely chosen and when it is controlled. Twelve healthy participants walked on an instrumented treadmill at their PWS and at three standardised speeds: 3, 4, and 5 km/h. They did so in three footwear conditions: (1) with a Rebound® Air Walker CAM boot on the right leg, (2) with a Rebound® Air Walker on the right leg and an Evenup Shoelift™ on the left, and (3) in normal footwear. Comparisons between footwear conditions were largely similar in the ipsilateral limb at PWS and at the standardised speeds, which included a decrease in total mechanical work and ankle joint work during CAM boot wear (p < 0.001). At the standardised speeds, total mechanical work and hip joint work were lower during CAM boot wear than wearing normal shoes and the Evenup Shoelift™ (p ≤ 0.014), although there were no differences between footwear conditions at PWS (p ≥ 0.095). As such, acute responses to CAM boot wear are different when speed is standardised compared to when speed is freely chosen, meaning conclusions cannot necessarily be transferred between approaches. Based on these differences observed between walking speeds, it would be prudent for future studies to try to maintain ecological validity by using PWS.

9 January 2024 in Sports Biomechanics
Verified
Journal Article
Closed access
BHBrian Hanley
Brian Hanley
ATAaron L. Thomas
Aaron L. Thomas
CTCatherine B. Tucker
Catherine B. Tucker
The aim of this study was to examine spatiotemporal and joint kinematic differences between footstrike patterns in 10,000 m running. Seventy-two men's and 42 women's footstrike patterns were analysed during laps 5, 10, 15, 20 and 25 (of 25) using 2D video recordings. Approximately 47% of men were FFS throughout the race, 30% were MFS and 24% RFS; the respective frequencies in women were approximately 30%, 38% and 32%. Overall, 83% of men and 88% of women retained their footstrike pattern throughout the race. Amongst the 53 men and 33 women with symmetrical footstrike patterns, there were no differences in speed, step length or cadence between footstrike groups in either sex. Most lower limb joint angles did not change in these athletes during the event, with few differences between footstrike patterns apart from ankle and foot angles. A greater hip-ankle distance was found in RFS than in FFS (both sexes) and in RFS than in MFS (men only), although these differences were never more than 0.03 m. Coaches should note that habitual footstrike patterns were maintained during this long-distance track race despite changes in running speed and possible fatigue, and there were few performance differences between footstrike patterns.