O. I. Ponomareva

O. I. Ponomareva

Auto-generated profile, based on publicly available information

O. I. Ponomareva

N.N. Petrov National Medical Research Center of Oncology, Ministry of Health of Russia

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
9 May 2025 in Cancer Urology
Verified
Journal Article
Open access
PDF file
RNR. V. Novikov
R. V. Novikov
VKV. K. Karandashov
V. K. Karandashov
TZT. V. Zhivulina
T. V. Zhivulina
OPO. I. Ponomareva
O. I. Ponomareva
IBI. A. Burovik
I. A. Burovik
SNS. N. Novikov
S. N. Novikov
Aim. To evaluate the immediate results of perineal implantation of a biodegradable spacer based on stabilized hyaluronic acid (SНA) of non-animal origin as a way to optimize radiation treatment of prostate cancer.Materials and methods. The study included 48 patients with verified low and intermediate risk prostate cancer per NCCN (National Comprehensive Cancer Network) who received five-fraction stereotactic radiotherapy as radical treatment. Prior to radiotherapy, all patients underwent insertion of a prostate-rectum biodegradable spacer (PRBS) based on synthetic SHA in the volume of 4–8 mL.Results. There were no allergic and inflammatory reactions of tissues to the chemical composition of the implanted PRBS. Despite the invasive nature of the procedure, we did not observe any cases of infectious complications.SНA used in the study demonstrated high levels of hydration (swelling) equal to 24.4 ± 1.5 (20.7–27.3) %, as well as temporal and spatial stability, which determined its optimal characteristics for use as a radiotherapeutic spacer. In all 48 patients, the projected distance (≥1 cm) between the prostate gland and the anterior wall of the rectum was achieved before the start of irradiation. The administration of 4 mL of SНA made it possible to achieve optimal symmetry of the formed space only in one (16.7 %) patient. An increase in the implant volume of the polymer to 6 mL increased the number of such cases to 28.6 %, and after injection of 8 mL it increased to 57 %.The use of PRBS made it possible to reduce radiation dose to the rectum from 21.5 % (D0.1cc (dose per 0.1 cm3 of rectum)) (р 0.0001) to 92.8 % (V75 % (volume receiving 75 % or more of the prescribed dose)) (р 0.0001). Dose reduction for one of the most clinically validated parameters – D2cc (dose to 2 cm3 of rectum)) was 31.5 % (р 0.0001) on average.Conclusion. Perineal implantation of a non-animal SНA (Russia) as a radiotherapy spacer in patients with prostate cancer demonstrates excellent safety and efficacy profiles.

6 May 2024 in Voprosy onkologii
Verified
Journal Article
Open access
СНСергей Николаевич Новиков
Сергей Николаевич Новиков
НИНиколай Дмитриевич Ильин
Николай Дмитриевич Ильин
ЮМЮлия Сергеевна Мельник
Юлия Сергеевна Мельник
ОПОльга Игоревна Пономарева
Ольга Игоревна Пономарева
РНРоман Владимирович Новиков
Роман Владимирович Новиков
СКСергей Васильевич Канаев
Сергей Васильевич Канаев
Aim. To evaluate efficacy and safety of stereotactic ablative radiotherapy (SABR) as a radical treatment of low and intermediate risk prostate cancer (LIRPC). Material and Methods. From April 2014 to June 2018, 111 primary patients with clinically localized LIRPC were treated with SABR as a monotherapy. SABR was delivered in 5 fractions of 7.25 Gy according to the standard technology: after 2-3 marker placement, MRI, X-ray computed tomography (CT) scanners, and using the Eclipse treatment planning system with the volumetric-modulated arc therapy (VMAT) planning. Five-year biochemical recurrence-free survival (BRFS) was assessed according to the «Phoenix definition» biochemical recurrence criteria. Toxicity was scored according to the RTOG and CTAE. Results. The median follow-up time was 78 (60-110) months. BRFS for both the groups was 91 %: 95.5 % - for low risk and 88.2 % - for intermediate risk patients. Local control was 97.3 %. Grade II genitourinary toxicity was detected in 11 cases (10 %) and grade III in 1 case (0.9 %). Grade II rectal toxicity was observed in 6 patients (5.4 %), while no grade III toxicity was observed. Conclusion. The results of the 5-year follow-up after SABR in LIRPC patients demonstrated the high efficacy and safety of the procedure, allowing it to be recommended for wide clinical use. Цель. Оценить эффективность и безопасность стереотаксической лучевой терапии (СТЛТ) рака предстательной железы в группах низкого и промежуточного риска прогрессирования (НПРП). Материалы и методы. С апреля 2014 г. по июнь 2018 г. СТЛТ использовалась в качестве метода монотерапии у 111 первичных больных раком предстательной железы НПРП. СТЛТ проводилась в режиме 5 фракций по 7,25 Гр по стандартной технологии: после установки 2-3 маркеров, выполнения топометрических исследований на магнитно-резонансном и рентгеновском компьютерном (КТ) томографах и планирования на системе Eclipse с применением техники объемно-модулированной лучевой терапии арками (ОМЛТ). Оценивалась пятилетняя выживаемость без признаков биохимического рецидива (ВБПБР) в соответствии с критериями биохимического рецидива «Phoenix definition». Токсичность оценивалась в соответствии с критериями RTOG и CTAE. Результаты. Медиана наблюдения составила 78 (60-110) мес. 5-летняя ВБПБР для обеих групп составила 91 %: 95,5 % для низкого риска и 88,2 % для пациентов из группы промежуточного риска прогрессирования. Локальный контроль был достигнут у 97,3 % больных. Поздние осложнения со стороны мочевыводящих путей соответствующие II степени отмечались в 11 случаях (10 %), III степени — в 1 случае (0,9 %). Токсичность со стороны прямой кишки II степени была отмечена у 6 пациентов (5,4 %), III степени — не наблюдалась. Выводы. Результаты 5-летнего наблюдения после СТЛТ у больных РПЖ НПРР доказали высокую эффективность и безопасность метода, что позволяет рекомендовать его для широкого клинического использования.

1 December 2024 in Cancer Urology
Verified
Journal Article
Open access
PDF file
RNR. V. Novikov
R. V. Novikov
GLG. A. Lyasovich
G. A. Lyasovich
OPO. I. Ponomareva
O. I. Ponomareva
VKV. K. Karandashov
V. K. Karandashov
IBI. A. Burovik
I. A. Burovik
SNS. N. Novikov
S. N. Novikov
Aim. To assess the impact of topographic anatomy of the critical structures of the penile vessels on the implementation of vessel-sparing radiation therapy for prostate cancer.Materials and methods. The study included 70 patients with verified prostate cancer. All patients underwent topometric computed tomography and magnetic resonance imaging. The target (prostate gland and proximal third of the seminal vesicles), standard critical structures (rectum, bladder, femoral heads), as well as critical vascular structures responsible for erectile function were delineated (bulb of the penis, crura of the corpus cavernosum, internal pudendal artery). The obtained images were subjected to volumetric and spatial analysis using the Eclipse 4.0 (Varian Medical System) planning system.Results. In all 70 patients, adequate visualization of all anatomical structures was achieved. The mean distance between the apex and the penile bulb was 1.35 ± 0.47 (0.35–2.41) cm. In the majority of patients, this index exceeded 1 cm: up to 1 cm – 18 (25.7 %), between 1.1 and 1.5 – 27 (38.6 %), and more than 1.51 cm – 25 (35.7 %). The apical-cavernous distance on the right and left did not differ significantly: 2.05 ± 0.45 (1.12–3.00) and 2.09 ± 0.44 (1.16–3.02) cm, respectively. The internal pudendal artery in the projection of the irradiated volume (prostate gland and proximal third of seminal vesicles) is located at an average distance of 2.5 cm (apex gland) to 4.3 cm (basal parts of the prostate). Analysis (Spearman’s correlation coefficient) did not reveal a significant relationship between the assessed spatial parameters and prostate volume and body mass index.Conclusion. The topographic relationship between the irradiated volumes and erectile vascular structures makes it possible to implement vessel-sparing radiation therapy protocol in the majority of cases (about 75 %).

14 April 2025 in Diagnostic radiology and radiotherapy
Verified
Journal Article
Open access
PDF file
RNR. V. Novikov
R. V. Novikov
GLG. A. Liasovich
G. A. Liasovich
EBE. S. Bykova
E. S. Bykova
OPO. I. Ponomareva
O. I. Ponomareva
VKV. K. Karandashev
V. K. Karandashev
VPV. V. Protoshchak
V. V. Protoshchak
INTRODUCTION: Тhe development of new methods of radical treatment of prostate cancer (PCa) aimed at maintaining a high quality of life is the most important task of modern oncourology. Radiation therapy with a dose reduction to the area of critical vascular erectile structures is one of them.OBJECTIVE: Сompare different approaches for «vessel-sparing» stereotactic radiation therapy (VS-SRT) PCa.MATERIALS AND METHODS: Тhe study included 20 patients with histologically confirmed PCa of low and intermediate risk of recurrence (NCCN). SRT was planed at five fractions of 7.25 Gy. During planning we ad to the standard critical organs, vascular structures that are responsible for erectile function (ErOAR)): penile bulb (PB), crura of the cavernous bodies (CCB) and internal pudendal arteries (IPA)). For each patient, four dosimetric plans (DP) were calculated: «vessel-sparing» (DP-VS); standard (DP-S); «vessel-sparing» plan calculated in the formation of the generally accepted anisotropic indent of 5 mm for the planned volume of irradiation and a step towards the rectum — 3 mm (DP-5/3); «vessel-sparing» plan for irradiation using a 0.5-centimeter multi-life collimator (DP-0.5). All dosimetry plans, with the exception of DP-0.5, were generated for a linear accelerator with a 0.25 cm multi-leaf collimator.RESULTS: Аll dosimetry plans, were cherecterized by exellent target coverage abd meet the prescribed limits for the critical organs. Most efficient sparing of ErOAR was achieved in DP-VS. The advantages of DP-VS in comparison with DP-S was significant reduction (30%) of D2% for CCB (IPA) (р0.05).DISCUSSION: Тhe obtained results indicate that VS-SRT is feasible in the vast majority of patients suffering from PCa. A significant reduction in the dose delivered to the ErOAR can be achieved at most linear electron accelerators equipped with modern multi-leaf collimators.CONCLUSION: The greatest contribution to the reduction of radiation dose to ErOAR in VS-SRT PC is made by the reduction of standard PTV, while the width of the collimator leaf does not have a significant effect on the dose priscribed to this region.

5 November 2025 in Voprosy onkologii
Verified
Journal Article
Open access
PDF file
СНСергей Николаевич Новиков
Сергей Николаевич Новиков
ЕТЕлена Ивановна Тюряева
Елена Ивановна Тюряева
РНРоман Владимирович Новиков
Роман Владимирович Новиков
ДСДенис Владимирович Самсонов
Денис Владимирович Самсонов
ПГПавел Юрьевич Гришко
Павел Юрьевич Гришко
АБАлексей Михайлович Беляев
Алексей Михайлович Беляев
Цель. Оценка частоты полных ответов после неоадъювантной сочетанной лучевой терапии с эскалацией дозы на остаточную опухоль. Материалы и методы. В предварительный анализ включены 48 больных с аденокарциномами нижнеампулярного отдела прямой кишки cT2-3N0-2, которым после стандартной дистанционной лучевой терапии проводилось дополнительное облучение оставшейся опухоли с помощью эндоректальной внутриполостной высокодозной брахитерапии (ЭРВБ) в режиме трех фракций по 7 Гр. Маркировка остаточной опухоли выполнялась эндоскопически перед ЭРВБ. Полный клинический ответ оценивался по стандартным критериям: отсутствие пальпируемых изменений, белый рубец при эндоскопии, картина полного ответа при магнитно-резонансной томографии (МРТ). Результаты. Через 8-12 нед. после облучения полный клинический ответ (cCR — clinical complete response) зарегистрирован у 25 из 48 (52 %) больных. Ответ, близкий к cCR, наблюдался в шести случаях. У 17 прооперированных больных полный патоморфологический ответ (pathologic Complete Response — pCR) установлен в семи случаях, т. е. у 41,2 %. В целом суммарный полный ответ (cСR+pСR) достигнут у 32 из 48 (66,6 %) пациентов. У больных сT2N0-1 cСR+pСR отмечался у 16 из 20 (80 %) больных, при более глубокой инвазии (сT3N0-2) — в 17 из 28 случаев (60,7 %). Поздние осложнения со стороны прямой кишки (I-II степени) наблюдались у 29 % неоперированных больных. Тяжелых осложнений (III и более степени) не отмечалось. Выводы. Использование ЭРВБ для дополнительного облучения остаточной опухоли обеспечивает высокую (60,7-80 %) вероятность достижения полного клинического ответа опухоли; значительная частота pCR у больных, которым проведено хирургическое лечение, ставит вопрос о необходимости пересмотра критериев cCR и/или сроков оценки ответа на лечение.

29 December 2023 in Voprosy onkologii
Verified
Journal Article
Open access
РНРоман Владимирович Новиков
Роман Владимирович Новиков
ОПОльга Игоревна Пономарева
Ольга Игоревна Пономарева
СНСергей Николаевич Новиков
Сергей Николаевич Новиков
ВКВасилий Кириллович Карандашев
Василий Кириллович Карандашев
ВПВладимир Владимирович Протощак
Владимир Владимирович Протощак
NINikolai Iglovikov
Nikolai Iglovikov
Aim. To evaluate the results of collagen spacer implantation, using magnetic resonance image (MRI) analysis. Materials and methods. The study included 50 patients with localized prostate cancer who had a spacer placed between the rectum and prostate before stereotactic radiotherapy (SRT) was performed. Introduction of the spacer based on synthetic collagen of animal origin was conducted according to the standard procedure under US control. In all cases, topometric MRI was done after spacer placement. Results. We conducted standard procedure to assess the quality of the spacer insertion using MRI imaging that represent various cases of excellent, acceptable and unsatisfactory spacer placement. Complications occurred in 2 out of 50 cases, specifically related to inserting an animal collagen-based spacer into the rectum wall. These complications did not manifest clinically and did not affect the treatment strategy. Conclusion. Presented MRI images illustrate efficacy and safety of collagen spacers in routine clinical practice. Цель. Оценка результатов имплантации коллагенового спейсера с помощью анализа магнитно-резонансных изображений (МРТ). Материалы и методы. В исследование включено 50 больных раком предстательной железы, которым перед проведением стереотаксической лучевой терапии вводился спейсер между предстательной железой и прямой кишкой. Спейсер на основе синтетического коллагена животного происхождения устанавливался по стандартной методике под УЗИ контролем. Во всех случаях после установки спейсера выполнялось топометрическая МРТ. Результаты. Представлены стандартные подходы к оценке качества при введении спейсера с помощью контрольной топометрической МРТ. Представлены возможные варианты успешной, удовлетворительной и неудовлетворительной установки спейсера. Из 50 случаев введения спейсера в 2 наблюдениях отмечены осложнения — введение спейсера в стенку прямой кишки. При использовании спейсера на основе животного коллагена указанные осложнения не имели клинических проявлений и не повлияли на тактику лечения больных. Выводы. В работе представлены типичные МР-изображения, которые подтверждают эффективность и безопасность использования первого отечественного спейсера на основе коллагена животного происхождения.