15 September 2020 in ACS Nano
18 August 2020 in Nanoscale
Electrokinetic focusing of analytes to a solid-state nanopore enhances the translocation event rate, enabling rapid nanopore sensing at low analyte concentrations.
7 March 2022 in Nanoscale
Purely electrical SARS-CoV-2 quantification based on single-molecule counting in a solid-state nanopore sensor. RNA from clinical samples is converted to double-stranded DNA without amplification and analyzed using the nanopore device.
5 September 2017 in Scientific Reports
The use of on-chip isotachophoresis assays for diagnostic applications is often limited by the small volumes of standard microfluidic channels. Overcoming this limitation is particularly important for detection of ‘discrete’ biological targets (such as bacteria) at low concentrations, where the volume of processed liquid in a standard microchannel might not contain any targets. We present a novel microfluidic chip that enables ITP focusing of target analytes from initial sample volumes of 50 μL into a concentrated zone with a volume of 500 pL, corresponding to a 100,000-fold increase in mean concentration, and a 300,000-fold increase in peak concentration. We present design considerations for limiting sample dispersion in such large-volume focusing (LVF) chips and discuss the trade-off between assay time and Joule heating, which ultimately governs the scalability of LVF designs. Finally, we demonstrate a 100-fold improvement of ITP focusing performance in the LVF chip as compared to conventional microchannels, and apply this enhancement to achieve highly sensitive detection of both molecular targets (DNA, down to 10 fM) and whole bacteria (down to 100 cfu/mL).
16 February 2015 in Applied Physics Letters
Microfluidic probes (MFPs) are a class of non-contact, scanning microfluidic devices that hydrodynamically confine nanoliter volumes of a processing liquid on a surface immersed in another liquid. So far only chemical processes using a single processing liquid have been implemented using MFPs. In this letter, we present the design and implementation of a probe head that allows segmented two-phase flows to be used, which will enable different chemical species to be sequentially delivered to a surface in defined volumes and concentrations. Central to this probe head is a spacer-removal module comprising blocking pillars in the injection channel, a bypass and an orifice leading to the aspiration channel. We present a capillarity-based analytical model that provides insight into the functionality of the module based on geometrical parameters. In addition, we study the difference between two- and three-channel modules and predict a reduction in fluctuation of the footprint of the confined liquid for the three-channel module. We show that such a module with a pillar spacing, a orifice width, and an oblique angle of can remove immiscible spacers (Fluorinert FC-40) from an aqueous flow at a rate of up to 15 spacers per second while maintaining hydrodynamic confinement of processing liquid.
25 October 2018 in Lab on a Chip
On-demand two-phase encapsulation of electrokinetically separated analytes decouples electrokinetic separations from downstream analytical processes.