Giju Thomas

Giju Thomas

Auto-generated profile, based on publicly available information

Giju Thomas

Vanderbilt Biophotonics Center Vanderbilt University Nashville Tennessee USA

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 April 2021 in Surgery
Verified
Journal Article
Closed access
CSCarmen C. Solórzano
Carmen C. Solórzano
GTGiju Thomas
Giju Thomas
EBEren Berber
Eren Berber
TWTracy S. Wang
Tracy S. Wang
GRGregory W. Randolph
Gregory W. Randolph
FTFrédéric Triponez
Frédéric Triponez

1 November 2018 in Thyroid®
Verified
Journal Article
Closed access
GTGiju Thomas
Giju Thomas
MMMelanie A. McWade
Melanie A. McWade
CPConstantine Paras
Constantine Paras
EMEmmanuel A. Mannoh
Emmanuel A. Mannoh
MSMelinda E. Sanders
Melinda E. Sanders
AMand Anita Mahadevan-Jansen
and Anita Mahadevan-Jansen
Background: Patients undergoing thyroidectomy may have inadvertent damage or removal of the parathyroid gland(s) due to difficulty in real-time parathyroid identification. Near-infrared autofluorescence (NIRAF) has been demonstrated as a label-free modality for intraoperative parathyroid identification with high accuracy. This study presents the translation of that approach into a user-friendly clinical prototype for rapid intraoperative guidance in parathyroid identification. Methods: A laboratory (lab)-built spectroscopy system that measures NIRAF in tissue was evaluated for identifying parathyroid glands in vivo across 162 patients undergoing thyroidectomy and/or parathyroidectomy. Based on these results, a clinical prototype called PTeye was designed with a user-friendly interface and subsequently investigated in 35 patients. The performance of the lab-built system and the clinical prototype were concurrently compared side by side by a single user with 20 patients in each group. The influence of (i) intrapatient and interpatient variability of NIRAF in thyroid and parathyroid glands and (ii) thyroid and parathyroid pathology on intraoperative parathyroid identification were investigated. The effect of blood on NIRAF intensity of parathyroid and thyroid was tested ex vivo with the PTeye system to assess if a hemorrhagic surgical field would affect parathyroid identification. Accuracy of both systems were determined by correlating the acquired data with either visual confirmation by a surgeon for unexcised parathyroid glands or histology reports for excised parathyroid glands. Results: The overall accuracy of the lab-built system in guiding parathyroid identification was 92.5%, while the PTeye system achieved an accuracy of 96.1%. Unlike the lab-built system, the PTeye could guide parathyroid identification even as the operating room lights remained on and required only 25% of the laser power used by the lab-built setup. Parathyroid glands had elevated NIRAF intensity compared to thyroid and other neck tissues, regardless of thyroid or parathyroid pathology. Blood did not seem to affect tissue NIRAF measurements obtained with both systems. Conclusion: In this study, the clinical prototype PTeye demonstrated high accuracy for label-free intraoperative parathyroid identification. The intuitive interface of the PTeye that can guide in identifying parathyroid tissue in the presence of ambient room lights suggests that it is a reliable and easy-to-use tool for surgical personnel.

19 October 2017 in Scientific Reports
Verified
Journal Article
Open access
PDF file
GTG. Thomas
G. Thomas
TNT.-Q. Nguyen
T.-Q. Nguyen
IPI. J. Pence
I. J. Pence
BCB. Caldwell
B. Caldwell
MOM. E. O’cOnnor
M. E. O’cOnnor
AMand Anita Mahadevan-Jansen
and Anita Mahadevan-Jansen
Breast conserving surgery is the preferred treatment for women diagnosed with early stage invasive breast cancer. To ensure successful breast conserving surgeries, efficient tumour margin resection is required for minimizing tumour recurrence. Currently surgeons rely on touch preparation cytology or frozen section analysis to assess tumour margin status intraoperatively. These techniques have suboptimal accuracy and are time-consuming. Tumour margin status is eventually confirmed using postoperative histopathology that takes several days. Thus, there is a need for a real-time, accurate, automated guidance tool that can be used during tumour resection intraoperatively to assure complete tumour removal in a single procedure. In this paper, we evaluate feasibility of a 3-dimensional scanner that relies on Raman Spectroscopy to assess the entire margins of a resected specimen within clinically feasible time. We initially tested this device on a phantom sample that simulated positive tumour margins. This device first scans the margins of the sample and then depicts the margin status in relation to an automatically reconstructed image of the phantom sample. The device was further investigated on breast tissues excised from prophylactic mastectomy specimens. Our findings demonstrate immense potential of this device for automated breast tumour margin assessment to minimise repeat invasive surgeries.

1 December 2014 in Journal of Photochemistry and Photobiology B: Biology
Verified
Journal Article
Closed access
GTGiju Thomas
Giju Thomas
JVJohan van Voskuilen
Johan van Voskuilen
HGHans C. Gerritsen
Hans C. Gerritsen
HJCM SterenborgHJCM Sterenborg
HJCM Sterenborg

1 January 2019 in Surgery
Verified
Journal Article
Closed access
GTGiju Thomas
Giju Thomas
MMMelanie A. McWade
Melanie A. McWade
JNJohn Q. Nguyen
John Q. Nguyen
MSMelinda E. Sanders
Melinda E. Sanders
JBJames T. Broome
James T. Broome
AMand Anita Mahadevan-Jansen
and Anita Mahadevan-Jansen

1 May 2018 in American Journal of Obstetrics and Gynecology
Verified
Journal Article
Closed access
COChristine M. O’brien
Christine M. O’brien
EVElizabeth Vargis
Elizabeth Vargis
ARAmy Rudin
Amy Rudin
JSJames C. Slaughter
James C. Slaughter
GTGiju Thomas
Giju Thomas
AMand Anita Mahadevan-Jansen
and Anita Mahadevan-Jansen