1 September 2012 in Construction and Building Materials
7 May 2018 in MATEC Web of Conferences
This paper describes the relationship between splitting tensile strength and compressive strength of self-consolidating concrete using data collected from laboratory specimens tested at standard conditions. The results were then compared with some expressions published in international literature. The investigated variables included: type of cement, percentage of nanosilica and percentage of microsilica as a cement replacement by weight. In spite of concrete not being designed to resist direct tension the knowledge of tensile strength is needed to estimate the cracking load. In the absence of test results an estimate of the tensile strength may be obtained by using the relationship proposed. The verification of the proposed formula based on experimental data was estimated by means of the integral absolute error (IAE). The output of this study has provided a better understanding of the correlation between splitting and compressive strengths of SCCs and the effect of some related variables on the resultant behavior, which has therefore, helped to generate new expression with better accuracy.
1 August 2013 in Cement and Concrete Composites
20 December 2021 in Innovative Infrastructure Solutions
1 November 2021 in Journal of Building Engineering
19 March 2019 in The Open Civil Engineering Journal
Background: Nano-silica is a new pozzolan that is boosting the field of nanomaterials and can be used effectively in the concrete industry. ASTM C1240 is used to qualify silica fume pozzolans for use in concrete and for marketing purposes. Objective: The present study aims to assess the adequacy of ASTM C1240 in qualifying nanosilica for use in concrete and to introduce a modified procedure to measure the pozzolanic activity of nanosilica used with cementitious composites. Methods: The effects of various particle sizes and dosages on the compressive strength of blends in standard mortar were investigated. The correlation between the chemical reactivity and the compressive strength were also investigated using TGA and XRD analyses. The criterion conceived was validated at two ages: 7 days and 28 days. Results and Conclusion: The strength activity index results revealed that the following standard procedure ASTM C1240 is not applicable for nanosilica due to the high surface area and great pozzolanic reactivity of SiO2 nanoparticles, so a lower cement replacement percentage should be used. This study suggests that it be no more than 7%. The pozzolanicity testing results confirm that a nanosilica replacement level of more than 7% could not be effective in transforming further Portlandite into a C-S-H or other major cementing compound, leading to a “false negative” for nanosilica pozzolans.