Hud Wahab

Hud Wahab

Auto-generated profile, based on publicly available information

Hud Wahab

University of New South Wales, Canberra, ACT 2600, Australia

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 August 2018 in Physical Review B
Verified
Journal Article
Closed access
PDF file
HMH.-Ch. Mertins
H.-Ch. Mertins
CJC. Jansing
C. Jansing
MKM. Krivenkov
M. Krivenkov
AVA. Varykhalov
A. Varykhalov
ORO. Rader
O. Rader
POP. M. Oppeneer
P. M. Oppeneer
Using polarization analysis of linearly polarized synchrotron radiation we demonstrate the existence of a giant magneto-optical Faraday effect at the carbon 1s edge of single-layer graphene on Co, reaching Faraday rotation angles of 2.9×105deg/mm. This value is of the order of those observed at the Co 3p and 2p edges. Using element-selective magnetic hysteresis curves we find that graphene on Co exhibits ferromagnetic order. The magnetism in graphene is found to be carried by and be strongly enhanced by aligned π orbitals of carbon atoms. It is induced by hybridization with the Co 3dz2 orbitals while carbon σ bonds show negligible magnetism due to insignificant hybridization with Co. From additional x-ray magnetic circular dichroism and transversal magneto-optical Kerr effect spectra a magnetic moment of 0.14μB is estimated for graphene. From Faraday spectra the complete set of x-ray magneto-optical constants of graphene has been deduced which allows for future modeling of magneto-optical devices based on graphene. The strong magnetism in graphene results from hybridization of carbon pz and metal 3d orbitals. Atoms of the graphene sublattice A, placed on top of Co, lead to strongest hybridization with Co 3dz2 orbitals. Carbon atoms of sublattice B, and those of rotated graphene domains without Co atoms beneath, hybridize with each other and with 3dxz and 3dyz orbitals of neighboring Co atoms forming tilted pz bonds. We show that the related reduction of A-B symmetry leads to a splitting of the spin-polarized density of conduction-band states which is responsible for the strong magneto-optical Faraday effect.

1 December 2016 in Carbon
Verified
Journal Article
Closed access
HWH. Wahab
H. Wahab
RHR. Haverkamp
R. Haverkamp
JKJ.H. Kim
J.H. Kim
JCJ.M. Cadogan
J.M. Cadogan
HMH.-Ch. Mertins
H.-Ch. Mertins
HTH. Timmers
H. Timmers

23 December 2023 in Ceramics International
Verified
Journal Article
Closed access
HWHud Wahab
Hud Wahab
JHJacob Heil
Jacob Heil
ATAlexander Scott Tyrrell
Alexander Scott Tyrrell
TMTodd Muller
Todd Muller
JAJohn Ackerman
John Ackerman
PJPatrick A. Johnson
Patrick A. Johnson

8 March 2013
Verified
Conference Paper
Closed access
PDF file
CTC. Tulea
C. Tulea
JCJ. Caron
J. Caron
HWH. Wahab
H. Wahab
NGN. Gehlich
N. Gehlich
MHM. Hoefer
M. Hoefer
RNR. Noll
R. Noll
Several laser systems in the infrared wavelength range, such as Nd:YAG, Er:YAG or CO2 lasers are used for efficient ablation of bone tissue. Here the application of short pulses in coaction with a thin water film results in reduced thermal side effects. Nonetheless up to now there is no laser-process for bone cutting in a clinical environment due to lack of ablation efficiency. Investigations of laser ablation rates of bone tissue using a rinsing system and concerning bleedings have not been reported yet. In our study we investigated the ablation rates of bovine cortical bone tissue, placed 1.5 cm deep in water under laminar flow conditions, using a short pulsed (25 ps), frequency doubled (532 nm) Nd:YVO4 laser with pulse energies of 1 mJ at 20 kHz repetition rate. The enhancement of the ablation rate due to debris removal by an additional water flow from a well-directed blast pipe as well as the negative effect of the admixture of bovine serum albumin to the water were examined. Optical Coherence Tomography (OCT) was used to measure the ablated volume. An experimental study of the depth dependence of the ablation rate confirms a simplified theoretical prediction regarding Beer-Lambert law, Fresnel reflection and a Gaussian beam profile. Conducting precise incisions with widths less than 1.5 mm the maximum ablation rate was found to be 0.2 mm3/s. At depths lower than 100 μm, while the maximum depth was 3.5 mm.

14 July 2015 in X-Ray Spectrometry
Verified
Journal Article
Closed access
PDF file
HWHud Wahab
Hud Wahab
GXGuangyuan Xu
Guangyuan Xu
CJChristine Jansing
Christine Jansing
MGMarkus Gilbert
Markus Gilbert
MTMarc F. Tesch
Marc F. Tesch
HTHeiko Timmers
Heiko Timmers

1 October 2018 in Carbon
Verified
Journal Article
Closed access
HWH. Wahab
H. Wahab
CJC. Jansing
C. Jansing
HMH.-Ch Mertins
H.-Ch Mertins
JKJ.H. Kim
J.H. Kim
SCSuk-Ho Choi
Suk-Ho Choi
HTH. Timmers
H. Timmers